330 research outputs found

    Visualisation of the local electrochemical activity of thermally-sprayed anti-corrosion coatings using scanning electrochemical microscopy

    Get PDF
    Scanning electrochemical microscopy was used to probe the local electrochemical activity of anti-corrosion coatings formed from Inconel 625, a Ni-Cr-Mo alloy commonly used in engineering applications. The coatings were formed using a high velocity oxygen fuel thermal spraying technique. Upon spraying onto mild steel substrates, clear splat boundaries were formed at the interface between droplets of the alloy as they cooled on the substrate surface. Scanning electrochemical microscopy in the feedback mode, employing ferrocenemethanol as redox mediator, was used to determine the local electrochemical activity of samples of the wrought alloy, the sintered alloy and the thermally-sprayed coating. Significantly, the wrought and sintered materials generally showed responses typical of those expected for a purely insulating material. However, feedback approach curve data showed that the electrochemical activity of the entire thermally-sprayed coating was higher than that of the bulk alloy. Local variations in the coating’s activity were then visualised using scanning electrochemical microscopy. These observations indicate that the spraying process increases the conductivity of Inconel 625 and that localised regions of increased electrochemical activity are generated throughout the material, which appear to be related to the splat boundaries formed during spraying

    A tunable amorphous p-type ternary oxide system: the highly mismatched alloy of copper tin oxide

    Get PDF
    The approach of combining two mismatched materials to form an amorphous alloy was used to synthesise ternary oxides of CuO and SnO2. These materials were analysed across a range of compositions, and the electronic structure was modelled using density functional theory. In contrast to the gradual reduction in optical band gap, the lms show a sharp reduction in both transparency and electrical resistivity with copper contents of greater than 50 %. Simulations indicate this change is caused by a transition from a dominant Sn 5s to Cu 3d contribution to the upper valence band. A corresponding decrease in energetic disorder results in increased charge percolation pathways: a `compositional mobility edge'. Contributions from Cu(II) sub band-gap states are responsible for the reduction in optical transparency

    Subclinical Hypothyroidism and the Risk of Stroke Events and Fatal Stroke: An Individual Participant Data Analysis.

    Get PDF
    OBJECTIVE: The objective was to determine the risk of stroke associated with subclinical hypothyroidism. DATA SOURCES AND STUDY SELECTION: Published prospective cohort studies were identified through a systematic search through November 2013 without restrictions in several databases. Unpublished studies were identified through the Thyroid Studies Collaboration. We collected individual participant data on thyroid function and stroke outcome. Euthyroidism was defined as TSH levels of 0.45-4.49 mIU/L, and subclinical hypothyroidism was defined as TSH levels of 4.5-19.9 mIU/L with normal T4 levels. DATA EXTRACTION AND SYNTHESIS: We collected individual participant data on 47 573 adults (3451 subclinical hypothyroidism) from 17 cohorts and followed up from 1972-2014 (489 192 person-years). Age- and sex-adjusted pooled hazard ratios (HRs) for participants with subclinical hypothyroidism compared to euthyroidism were 1.05 (95% confidence interval [CI], 0.91-1.21) for stroke events (combined fatal and nonfatal stroke) and 1.07 (95% CI, 0.80-1.42) for fatal stroke. Stratified by age, the HR for stroke events was 3.32 (95% CI, 1.25-8.80) for individuals aged 18-49 years. There was an increased risk of fatal stroke in the age groups 18-49 and 50-64 years, with a HR of 4.22 (95% CI, 1.08-16.55) and 2.86 (95% CI, 1.31-6.26), respectively (p trend 0.04). We found no increased risk for those 65-79 years old (HR, 1.00; 95% CI, 0.86-1.18) or ≄ 80 years old (HR, 1.31; 95% CI, 0.79-2.18). There was a pattern of increased risk of fatal stroke with higher TSH concentrations. CONCLUSIONS: Although no overall effect of subclinical hypothyroidism on stroke could be demonstrated, an increased risk in subjects younger than 65 years and those with higher TSH concentrations was observed

    Thyroid Function Within the Reference Range and the Risk of Stroke: An Individual Participant Data Analysis.

    Get PDF
    The currently applied reference ranges for thyroid function are under debate. Despite evidence that thyroid function within the reference range is related with several cardiovascular disorders, its association with the risk of stroke has not been evaluated previously. We identified studies through a systematic literature search and the Thyroid Studies Collaboration, a collaboration of prospective cohort studies. Studies measuring baseline TSH, free T4, and stroke outcomes were included, and we collected individual participant data from each study, including thyroid function measurements and incident all stroke (combined fatal and nonfatal) and fatal stroke. The applied reference range for TSH levels was between 0.45 and 4.49 mIU/L. We collected individual participant data on 43 598 adults with TSH within the reference range from 17 cohorts, with a median follow-up of 11.6 years (interquartile range 5.1-13.9), including 449 908 person-years. Age- and sex-adjusted pooled hazard ratio for TSH was 0.78 (95% confidence interval [CI] 0.65-0.95 across the reference range of TSH) for all stroke and 0.83 (95% CI 0.62-1.09) for fatal stroke. For the free T4 analyses, the hazard ratio was 1.08 (95% CI 0.99-1.15 per SD increase) for all stroke and 1.10 (95% CI 1.04-1.19) for fatal stroke. This was independent of cardiovascular risk factors including systolic blood pressure, total cholesterol, smoking, and prevalent diabetes. Higher levels of TSH within the reference range may decrease the risk of stroke, highlighting the need for further research focusing on the clinical consequences associated with differences within the reference range of thyroid function

    Measurement of the B0-anti-B0-Oscillation Frequency with Inclusive Dilepton Events

    Get PDF
    The B0B^0-Bˉ0\bar B^0 oscillation frequency has been measured with a sample of 23 million \B\bar B pairs collected with the BABAR detector at the PEP-II asymmetric B Factory at SLAC. In this sample, we select events in which both B mesons decay semileptonically and use the charge of the leptons to identify the flavor of each B meson. A simultaneous fit to the decay time difference distributions for opposite- and same-sign dilepton events gives Δmd=0.493±0.012(stat)±0.009(syst)\Delta m_d = 0.493 \pm 0.012{(stat)}\pm 0.009{(syst)} ps−1^{-1}.Comment: 7 pages, 1 figure, submitted to Physical Review Letter

    Time-integrated luminosity recorded by the BABAR detector at the PEP-II e+e- collider

    Get PDF
    This article is the Preprint version of the final published artcile which can be accessed at the link below.We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e+e- collider at the ϒ(4S), ϒ(3S), and ϒ(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e+e-→e+e- and (for the ϒ(4S) only) e+e-→Ό+ÎŒ- candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e+e-→e+e- and e+e-→Ό+ÎŒ-, the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the ϒ(3S) and ϒ(2S) resonances, an additional uncertainty arises due to ϒ→e+e-X background. For data collected off the ϒ resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the ϒ(4S), 0.58% (0.72%) for the ϒ(3S), and 0.68% (0.88%) for the ϒ(2S).This work is supported by the US Department of Energy and National Science Foundation, the Natural Sciences and Engineering Research Council (Canada), the Commissariat Ă  l’Energie Atomique and Institut National de Physique NuclĂ©aire et de Physiquedes Particules (France), the Bundesministerium fĂŒr Bildung und Forschung and Deutsche Forschungsgemeinschaft (Germany), the Istituto Nazionale di Fisica Nucleare (Italy), the Foundation for Fundamental Research on Matter (The Netherlands), the Research Council of Norway, the Ministry of Education and Science of the Russian Federation, Ministerio de Ciencia e InnovaciĂłn (Spain), and the Science and Technology Facilities Council (United Kingdom). Individuals have received support from the Marie-Curie IEF program (European Union) and the A.P. Sloan Foundation (USA)

    Detector Description and Performance for the First Coincidence Observations between LIGO and GEO

    Get PDF
    For 17 days in August and September 2002, the LIGO and GEO interferometer gravitational wave detectors were operated in coincidence to produce their first data for scientific analysis. Although the detectors were still far from their design sensitivity levels, the data can be used to place better upper limits on the flux of gravitational waves incident on the earth than previous direct measurements. This paper describes the instruments and the data in some detail, as a companion to analysis papers based on the first data.Comment: 41 pages, 9 figures 17 Sept 03: author list amended, minor editorial change

    Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC

    No full text
    CVD diamond shows promising properties for use as a position sensitive detector for experiments in the highest radiation areas at the Large Hadron Collider. In order to study the radiation hardn ess of diamond we exposed CVD diamond detector samples to 24~GeV/cc and 500~MeV protons up to a fluence of 5×1015 p/cm25\times 10^{15}~p/{\rm cm^2}. We measured the charge collection distance, the ave rage distance electron hole pairs move apart in an external electric field, and leakage currents before, during, and after irradiation. The charge collection distance remains unchanged up to 1 times1015 p/cm21\ times 10^{15}~p/{\rm cm^2} and decreases by ≈\approx40~\% at 5×1015 p/cm25\times 10^{15}~p/{\rm cm^2}. Leakage currents of diamond samples were below 1~pA before and after irradiation. The particle indu ced currents during irradiation correlate well with the proton flux. In contrast to diamond, a silicon diode, which was irradiated for comparison, shows the known large increase in leakage curren t. We conclude that CVD diamond detectors are radiation hard to 24~GeV/cc and 500~MeV protons up to at least 1×1015 p/cm21\times 10^{15}~p/{\rm cm^2} without signal loss
    • 

    corecore