159 research outputs found

    Interactions Between Zooplankton and Karenia brevis in the Gulf of Mexico.

    Get PDF
    Blooms of the toxic dinoflagellate K. brevis are common in the Gulf of Mexico, yet no in situ studies of the interactions between zooplankton and K. brevis in the Gulf of Mexico have been conducted. Zooplankton numerical abundance, biomass and taxonomic composition of nonbloom and K. brevis bloom stations within the ECOHAB study area were compared. At nonbloom stations, the most important determinant species were Parvolcalanus crassirostris, Oithona colcarva and Paracalanus quasimodo at the 5-m isobath and P. quasimodo, O. colcarva and Oikopleura dioka at the 25-m isobath. There was considerable overlap between the 5 and 25-m isobaths, with 9 species contributing to the top 90% of numerical abundance at both isobaths. Within K. brevis blooms Acartia tonsa, Centropages velificatus, Temora turbinata, Evadne tergestina, O. colcarva, O. dioika, and P. crassirostris were consistently dominant. Variations between non-bloom and bloom assemblages were evident, including variations in numerical abundance and biomass and the reduction in numerical abundance of 3 key species. Calculated grazing pressure proved insufficient to terminate K. brevis blooms, despite occasional grazing hot spots

    Ultracold collisions of oxygen molecules

    Full text link
    Collision cross sections and rate constants between two ground- state oxygen molecules are investigated theoretically at translational energies below 1\sim 1K and in zero magnetic field. We present calculations for elastic and spin- changing inelastic collision rates for different isotopic combinations of oxygen atoms as a prelude to understanding their collisional stability in ultracold magnetic traps. A numerical analysis has been made in the framework of a rigid- rotor model that accounts fully for the singlet, triplet, and quintet potential energy surfaces in this system. The results offer insights into the effectiveness of evaporative cooling and the properties of molecular Bose- Einstein condensates, as well as estimates of collisional lifetimes in magnetic traps. Specifically, 17O2^{17}O_{2} looks like a good candidate for ultracold studies, while 16O2^{16}O_{2} is unlikely to survive evaporative cooling. Since 17O2^{17}O_{2} is representative of a wide class of molecules that are paramagnetic in their ground state we conclude that many molecules can be successfully magnetically trapped at ultralow temperatures.Comment: 15 pages, 9 figure

    Validation of the Actical Activity Monitor in Middle-Aged and Older Adults

    Get PDF
    Purpose: This study was designed to validate the Actical activity monitor in middle-aged and older adults of varying body composition to develop accelerometer thresholds to distinguish between light and moderate intensity physical activity (PA). Methods: Nonobese 45 to 64 yr (N = 29), obese 45 to 64 yr (N = 21), and ≥65 yr (N = 23; varying body composition) participants completed laboratory-based sitting, household, and locomotive activities while wearing an Actical monitor and a portable metabolic measurement system. Non-linear regression analysis was used to identify activity count (AC) cut-points to differentiate between light intensity (\u3c3 METs) and moderate intensity (≥3 METs) PA. Results: Using group-specific algorithms, AC cut points for 3 METs were 1634, 1107, and 431 for the obese 45 to 64 yr group, nonobese 45 to 64 yr group, and ≥65 yr group, respectively. However, sensitivity and specificity analysis revealed that an AC cut-point of 1065 yielded similar accuracy for detecting an activity as less than or greater than 3 METs, regardless of age and body composition. Conclusion: For the Actical activity monitor, an AC cut-point of 1065 can be used to determine light and moderate intensity PA in people ≥45 years of age

    Response to reduced nicotine content cigarettes among smokers differing in tobacco dependence severity

    Get PDF
    This study examines whether tobacco dependence severity moderates the acute effects of reducing nicotine content in cigarettes on the addiction potential of smoking, craving/withdrawal, or smoking topography. Participants (N = 169) were daily smokers with mild, moderate, or high tobacco-dependence severity using the Heaviness of Smoking Index. Following brief abstinence, participants smoked research cigarettes varying in nicotine content (0.4, 2.4, 5.2, 15.8 mg nicotine/g tobacco) in a within-subject design. Results were analyzed using repeated measures analysis of co-variance. No main effects of dependence severity or interactions with nicotine dose were noted in relative reinforcing effects in concurrent choice testing or subjective effects on the modified Cigarette Evaluation Questionnaire. Demand for smoking in the Cigarette Purchase Task was greater among more dependent smokers, but reducing nicotine content decreased demand independent of dependence severity. Dependence severity did not significantly alter response to reduced nicotine content cigarettes on the Minnesota Tobacco Withdrawal Scale nor Questionnaire of Smoking Urges-brief (QSU) Factor-2 scale; dependence severity and dose interacted significantly on the QSU-brief Factor-1 scale, with reductions dependent on dose among highly but not mildly or moderately dependent smokers. Dependence severity and dose interacted significantly on only one of six measures of smoking topography (i.e., maximum flow rate), which increased as dose increased among mildly and moderately but not highly dependent smokers. These results suggest that dependence severity has no moderating influence on the ability of reduced nicotine content cigarettes to lower the addiction potential of smoking, and minimal effects on relief from craving/withdrawal or smoking topography

    Pulse shape analysis of signals from BaF2 and CeF3 scintillators for neutron capture experiments

    Get PDF
    The scope of this work is to study the characteristics of BaF2 and CeF3 signals using fast digitizers, which allow the sampling of the signal at very high frequencies and the application of the fitting method for analysis of the recorded pulses. By this procedure particle identification and the reconstruction of pile-up events can be improved, while maintaining the energy and time-of-flight resolution as compared to traditional methods. The reliability of the technique and problems connected with data acquisition are discussed with respect to accurate measurements of neutron capture cross-sections

    Frame expansions for Gabor multipliers

    Get PDF
    AbstractDiscrete Gabor multipliers are composed of rank one operators. We shall prove, in the case of rank one projection operators, that the generating operators for such multipliers are either Riesz bases (exact frames) or not frames for their closed linear spans. The same dichotomy conclusion is valid for general rank one operators under mild and natural conditions. This is relevant since discrete Gabor multipliers have an emerging role in communications, radar, and waveform design, where redundant frame decompositions are increasingly applicable

    Aptamer-based multiplexed proteomic technology for biomarker discovery

    Get PDF
    Interrogation of the human proteome in a highly multiplexed and efficient manner remains a coveted and challenging goal in biology. We present a new aptamer-based proteomic technology for biomarker discovery capable of simultaneously measuring thousands of proteins from small sample volumes (15 [mu]L of serum or plasma). Our current assay allows us to measure ~800 proteins with very low limits of detection (1 pM average), 7 logs of overall dynamic range, and 5% average coefficient of variation. This technology is enabled by a new generation of aptamers that contain chemically modified nucleotides, which greatly expand the physicochemical diversity of the large randomized nucleic acid libraries from which the aptamers are selected. Proteins in complex matrices such as plasma are measured with a process that transforms a signature of protein concentrations into a corresponding DNA aptamer concentration signature, which is then quantified with a DNA microarray. In essence, our assay takes advantage of the dual nature of aptamers as both folded binding entities with defined shapes and unique sequences recognizable by specific hybridization probes. To demonstrate the utility of our proteomics biomarker discovery technology, we applied it to a clinical study of chronic kidney disease (CKD). We identified two well known CKD biomarkers as well as an additional 58 potential CKD biomarkers. These results demonstrate the potential utility of our technology to discover unique protein signatures characteristic of various disease states. More generally, we describe a versatile and powerful tool that allows large-scale comparison of proteome profiles among discrete populations. This unbiased and highly multiplexed search engine will enable the discovery of novel biomarkers in a manner that is unencumbered by our incomplete knowledge of biology, thereby helping to advance the next generation of evidence-based medicine

    The state of the Martian climate

    Get PDF
    60°N was +2.0°C, relative to the 1981–2010 average value (Fig. 5.1). This marks a new high for the record. The average annual surface air temperature (SAT) anomaly for 2016 for land stations north of starting in 1900, and is a significant increase over the previous highest value of +1.2°C, which was observed in 2007, 2011, and 2015. Average global annual temperatures also showed record values in 2015 and 2016. Currently, the Arctic is warming at more than twice the rate of lower latitudes

    A prospective evaluation of the safety and efficacy of the TAXUS Element paclitaxel-eluting coronary stent system for the treatment of de novo coronary artery lesions: Design and statistical methods of the PERSEUS clinical program

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Paclitaxel-eluting stents decrease angiographic and clinical restenosis following percutaneous coronary intervention compared to bare metal stents. TAXUS Element is a third-generation paclitaxel-eluting stent which incorporates a novel, thinner-strut, platinum-enriched metal alloy platform. The stent is intended to have enhanced radiopacity and improved deliverability compared to other paclitaxel-eluting stents. The safety and efficacy of the TAXUS Element stent are being evaluated in the pivotal PERSEUS clinical trials.</p> <p>Methods/Design</p> <p>The PERSEUS trials include two parallel studies of the TAXUS Element stent in single, de novo coronary atherosclerotic lesions. The PERSEUS Workhorse study is a prospective, randomized (3:1), single-blind, non-inferiority trial in subjects with lesion length ≤28 mm and vessel diameter ≥2.75 mm to ≤4.0 mm which compares TAXUS Element to the TAXUS Express<sup>2 </sup>paclitaxel-eluting stent system. The Workhorse study employs a novel Bayesian statistical approach that uses prior information to limit the number of study subjects exposed to the investigational device and thus provide a safer and more efficient analysis of the TAXUS Element stent. PERSEUS Small Vessel is a prospective, single-arm, superiority trial in subjects with lesion length ≤20 mm and vessel diameter ≥2.25 mm to <2.75 mm that compares TAXUS Element with a matched historical bare metal Express stent control.</p> <p>Discussion</p> <p>The TAXUS PERSEUS clinical trial program uses a novel statistical approach to evaluate whether design and metal alloy iterations in the TAXUS Element stent platform provide comparable safety and improved procedural performance compared to the previous generation Express stent. PERSEUS trial enrollment is complete and primary endpoint data are expected in 2010. PERSEUS Workhorse and Small Vessel are registered at <url>http://www.clinicaltrials.gov</url>, identification numbers NCT00484315 and NCT00489541.</p
    corecore