452 research outputs found

    Inspiratory Muscle Training Improves Blood Flow to Resting and Exercising Limbs in Patients With Chronic Heart Failure

    Get PDF
    ObjectivesWe tested the hypothesis that inspiratory muscle loading could result in exaggerated peripheral vasoconstriction in resting and exercising limbs and that inspiratory muscle training (IMT) could attenuate this effect in patients with chronic heart failure (CHF) and inspiratory muscle weakness.BackgroundInspiratory muscle training improves functional capacity of patients with CHF, but the mechanisms of this effect are unknown.MethodsEighteen patients with CHF and inspiratory muscle weakness (maximal inspiratory pressure <70% of predicted) and 10 healthy volunteers participated in the study. Inspiratory muscle loading was induced by the addition of inspiratory resistance of 60% of maximal inspiratory pressure, while blood flow to the resting calf (CBF) and exercising forearm (FBF) were measured by venous occlusion plethysmography. For the patients with CHF, blood flow measurements as well as ultrasound determination of diaphragm thickness were made before and after a 4-week program of IMT.ResultsWith inspiratory muscle loading, CHF patients demonstrated a more marked reduction in resting CBF and showed an attenuated rise in exercising FBF when compared with control subjects. After 4 weeks of IMT, CHF patients presented hypertrophy of the diaphragm and improved resting CBF and exercise FBF with inspiratory muscle loading.ConclusionsIn patients with CHF and inspiratory muscle weakness, inspiratory muscle loading results in marked reduction of blood flow to resting and exercising limbs. Inspiratory muscle training improves limb blood flow under inspiratory loading in these patients

    The LHCb experiment control system : on the path to full automation

    No full text
    http://accelconf.web.cern.ch/AccelConf/icalepcs2011/papers/mobaust06.pdfInternational audienceThe experiment control system is in charge of the configuration, control and monitoring of the different subdetectors and of all areas of the online system. The building blocks of the control system are based on the PVSS SCADA System complemented by a control Framework developed in common for the 4 LHC experiments. This framework includes an "expert system" like tool called SMI++ which is used for the system automation. The experiment's operations are now almost completely automated, driven by a top-level object called Big-Brother, which pilots all the experiment's standard procedures and the most common error-recovery procedures. The architecture, tools and mechanisms used for the implementation as well as some operational examples will be described

    Graded morphologies and the performance of PffBT4T-2OD:PC71BM devices using additive choice

    Get PDF
    The impact of several solvent processing additives (1-chloronaphthalene, methylnaphthalene, hexadecane, 1-phenyloctane, and p-anisaldehyde), 3% v/v in o-dichlorobenzene, on the performance and morphology of poly[(5,6-difluoro-2,1,3-benzothiadiazol-4,7-diyl)-alt-(3,3‴-di(2-octyldodecyl)-2,2′,5′,22033,5″,2‴-quaterthiophen-5,5‴-diyl)] (PffBT4T-2OD):[6,6]-phenyl-C71-butyric acid methyl ester (PC71BM)-based polymer solar cells was investigated. Some additives were shown to enhance the power conversion efficiency (PCE) by ~6%, while others decreased the PCE by ~17–25% and a subset of the additives tested completely eliminated any power conversion efficiency and the operation as a photovoltaic device. Grazing-Incidence Wide Angle X-ray Scattering (GIWAXS) revealed a clear stepwise variation in the crystallinity of the systems when changing the additive between the two extreme situations of maximum PCE (1-chloronaphthalene) and null PCE (hexadecane). Small-Angle Neutron Scattering (SANS) revealed that the morphology of devices with PCE ~0% was composed of large domains with correlation lengths of ~30 nm, i.e., much larger than the typical exciton diffusion length (~12 nm) in organic semiconductors. The graded variations in crystallinity and in nano-domain size observed between the two extreme situations (1-chloronaphthalene and hexadecane) were responsible for the observed graded variations in device performance

    Interconexão entre células solares de perovskita e silício em dispositivos monolíticos Tandem de 2 terminais : estado da arte e desenvolvimentos futuros

    Get PDF
    CIES2020 - XVII Congresso Ibérico e XIII Congresso Ibero-americano de Energia SolarRESUMO: A formação de uma junção de efeito túnel é um fator chave para atingir altas eficiências em células solares tandem. As técnicas reportadas para a formação de junções de silício em dispositivos monolíticos tandem de 2 terminais como a Deposição Química de Vapor Assistida por Plasma (PECVD) ou a Implantação Iónica possuem restrições do ponto de vista de custos ou de aplicação ao nível industrial. A alternativa em estudo assenta na aplicação da técnica de dopagem por laser para a fabricação de junções de efeito túnel de silício com elevado grau de cristalinidade. Para isso desenvolveu-se um setup que recorre a um laser pulsado com emissão na região do infravermelho Nd:YAG (1064nm) para fusão superficial do silício e à utilização de oxicloreto de fósforo (POCl3) como fonte de dopante. O laser está acoplado a uma cabeça galvanométrica com lente f-teta de forma a permitir redireccionar e focar o feixe na superfície da amostra. O processo em causa possui várias vantagens face a outros já utilizados, uma vez que é facilmente escalável, rápido, com potencial baixo custo de processamento e eficiente do ponto de vista energético.ABSTRACT: The formation of a junction with tunneling effect is a key factor to achieve high efficiencies in tandem solar cells. The techniques reported for the formation of silicon junctions in 2-terminal tandem monolithic devices such as Plasma Assisted Vapor Chemical Deposition (PECVD) or Ionic Implantation have cost and application constrains at the industrial level. The alternative under study is based on the application of the laser doping technique for the manufacture of a silicon tunnel junction with a high degree of crystallinity. For this, a setup was developed using a pulsed laser with emission in the infrared region Nd:YAG (1064nm) for shallow surface melting of the silicon wafer and the use of phosphorus oxychloride (POCl3) as a source of dopant. The laser is coupled to a galvanometric head with a f-theta lens to allow redirecting and focusing the beam on the surface of the sample. This process has several advantages compared to others, since it is easily scalable, fast, energy efficient while presenting potentially low processing costs.info:eu-repo/semantics/publishedVersio

    Hadron Energy Reconstruction for the ATLAS Calorimetry in the Framework of the Non-parametrical Method

    Get PDF
    This paper discusses hadron energy reconstruction for the ATLAS barrel prototype combined calorimeter (consisting of a lead-liquid argon electromagnetic part and an iron-scintillator hadronic part) in the framework of the non-parametrical method. The non-parametrical method utilizes only the known e/he/h ratios and the electron calibration constants and does not require the determination of any parameters by a minimization technique. Thus, this technique lends itself to an easy use in a first level trigger. The reconstructed mean values of the hadron energies are within ±1\pm 1% of the true values and the fractional energy resolution is [(58±3)/E+(2.5±0.3)[(58\pm3)% /\sqrt{E}+(2.5\pm0.3)%]\oplus (1.7\pm0.2)/E. The value of the e/he/h ratio obtained for the electromagnetic compartment of the combined calorimeter is 1.74±0.041.74\pm0.04 and agrees with the prediction that e/h>1.7e/h > 1.7 for this electromagnetic calorimeter. Results of a study of the longitudinal hadronic shower development are also presented. The data have been taken in the H8 beam line of the CERN SPS using pions of energies from 10 to 300 GeV.Comment: 33 pages, 13 figures, Will be published in NIM

    Search for composite and exotic fermions at LEP 2

    Get PDF
    A search for unstable heavy fermions with the DELPHI detector at LEP is reported. Sequential and non-canonical leptons, as well as excited leptons and quarks, are considered. The data analysed correspond to an integrated luminosity of about 48 pb^{-1} at an e^+e^- centre-of-mass energy of 183 GeV and about 20 pb^{-1} equally shared between the centre-of-mass energies of 172 GeV and 161 GeV. The search for pair-produced new leptons establishes 95% confidence level mass limits in the region between 70 GeV/c^2 and 90 GeV/c^2, depending on the channel. The search for singly produced excited leptons and quarks establishes upper limits on the ratio of the coupling of the excited fermio

    Search for lightest neutralino and stau pair production in light gravitino scenarios with stau NLSP

    Get PDF
    Promptly decaying lightest neutralinos and long-lived staus are searched for in the context of light gravitino scenarios. It is assumed that the stau is the next to lightest supersymmetric particle (NLSP) and that the lightest neutralino is the next to NLSP (NNLSP). Data collected with the Delphi detector at centre-of-mass energies from 161 to 183 \GeV are analysed. No evidence of the production of these particles is found. Hence, lower mass limits for both kinds of particles are set at 95% C.L.. The mass of gaugino-like neutralinos is found to be greater than 71.5 GeV/c^2. In the search for long-lived stau, masses less than 70.0 to 77.5 \GeVcc are excluded for gravitino masses from 10 to 150 \eVcc . Combining this search with the searches for stable heavy leptons and Minimal Supersymmetric Standard Model staus a lower limit of 68.5 \GeVcc may be set for the stau mas

    HTLV-1 infection in solid organ transplant donors and recipients in Spain

    Get PDF
    Background: HTLV-1 infection is a neglected disease, despite infecting 10–15 million people worldwide and severe illnesses develop in 10% of carriers lifelong. Acknowledging a greater risk for developing HTLV-1 associated illnesses due to immunosuppression, screening is being widely considered in the transplantation setting. Herein, we report the experience with universal HTLV testing of donors and recipients of solid organ transplants in a survey conducted in Spain. Methods: All hospitals belonging to the Spanish HTLV network were invited to participate in the study. Briefly, HTLV antibody screening was performed retrospectively in all specimens collected from solid organ donors and recipients attended since the year 2008. Results: A total of 5751 individuals were tested for HTLV antibodies at 8 sites. Donors represented 2312 (42.2%), of whom 17 (0.3%) were living kidney donors. The remaining 3439 (59.8%) were recipients. Spaniards represented nearly 80%. Overall, 9 individuals (0.16%) were initially reactive for HTLV antibodies. Six were donors and 3 were recipients. Using confirmatory tests, HTLV-1 could be confirmed in only two donors, one Spaniard and another from Colombia. Both kidneys of the Spaniard were inadvertently transplanted. Subacute myelopathy developed within 1 year in one recipient. The second recipient seroconverted for HTLV-1 but the kidney had to be removed soon due to rejection. Immunosuppression was stopped and 3 years later the patient remains in dialysis but otherwise asymptomatic. Conclusion: The rate of HTLV-1 is low but not negligible in donors/recipients of solid organ transplants in Spain. Universal HTLV screening should be recommended in all donor and recipients of solid organ transplantation in Spain. Evidence is overwhelming for very high virus transmission and increased risk along with the rapid development of subacute myelopath

    Rapid subacute myelopathy following kidney transplantation from HTLV-1 donors: role of immunosuppresors and failure of antiretrovirals

    Get PDF
    Two kidney transplant recipients from a single donor became infected with HTLV-1 (human T-lymphotropic virus type 1) in Spain. One developed myelopathy 8 months following surgery despite early prescription of antiretroviral therapy. The allograft was removed from the second recipient at month 8 due to rejection and immunosuppressors discontinued. To date, 3 years later, this patient remains infected but asymptomatic. HTLV-1 infection was recognized retrospectively in the donor, a native Spaniard who had sex partners from endemic regions. Our findings call for a reappraisal of screening policies on donor-recipient organ transplantation. Based on the high risk of disease development and the large flux of persons from HTLV-1 endemic regions, pre-transplant HTLV-1 testing should be mandatory in Spain

    Melhoramento do sobreiro para uma regeneração artificial sustentável

    Get PDF
    O sobreiro (Quercus suber) é uma espécie singular devido à sua importância no funcionamento do ecossistema mediterrânico e na produção de cortiça. No entanto, apesar da sua importância ecológica e sócio-económica, pouco se compreende ainda dos seus processos de adaptabilidade às diferentes condições ambientais. Em algumas áreas do mediterrâneo ocidental, as florestas de sobreiro encontram-se em declínio e a manutenção destes ecossistemas requer a compreensão do seu funcionamento (e.g. regeneração, crescimento e interações entre hospedeiro e pragas/doenças). Para além de uma crescente redução da área de floresta, o sobreiro apresenta geralmente uma reduzida regeneração natural. Nos últimos anos, largas áreas de sobreiro foram reflorestadas no entanto, a regeneração artificial, quer por sementeira quer por plantação, obteve resultados variáveis com baixas taxas de sobrevivência. Apesar da necessidade de melhorar o manuseamento das sementes e das técnicas de produção e plantação ser geralmente reconhecida pelos proprietários florestais, a utilização de material genético adequado é quase sempre ignorada. De forma a dar resposta a alguns destes problemas está em curso o projeto PTDC/AGR-AAM/104364/2008: Melhoramento do sobreiro para uma regeneração artificial sustentável, que tem como principal objetivo melhorar a qualidade genética e fisiológica do material reprodutivo de sobreiro usado nas arborizações, focando-se em três aspetos essenciais: adaptabilidade da espécie, armazenamento da semente a longo prazo e produção de semente. Este é um trabalho multidisciplinar onde se integram os resultados de várias perspetivas – ecofisiológica, genética quantitativa e biologia molecular – de forma a compreender as suas interações e avaliar a plasticidade fenotípica, particularmente em condições de secura, contribuindo para ajustar os limites das regiões de proveniência e definir zonas de transferência de sementes
    corecore