270 research outputs found

    Exposure to biomass smoke extract enhances fibronectin release from fibroblasts

    Get PDF
    COPD induced following biomass smoke exposure has been reported to be associated with a more fibrotic phenotype than cigarette smoke induced COPD. This study aimed to investigate if biomass smoke induced extracellular matrix (ECM) protein production from primary human lung fibroblasts in vitro. Primary human lung fibroblasts (n = 5-10) were stimulated in vitro for up to 72 hours with increasing concentrations of biomass smoke extract (BME) or cigarette smoke extract (CSE) prior to being assessed for deposition of ECM proteins, cytokine release, and activation of intracellular signalling molecules. Deposition of the ECM proteins perlecan and fibronectin was upregulated by both CSE (p,0.05) and BME (p,0.05). The release of the neutrophilic chemokine IL-8 was also enhanced by BME. ERK1/2 phosphorylation was significantly upregulated by BME (p,0.05). Chemical inhibition of ERK signalling molecules partially attenuated these effects (p,0.05). Stimulation with endotoxin had no effect. This study demonstrated that BME had similar effects to CSE in vitro and had the capacity to directly induce fibrosis by upregulating production of ECM proteins. The mechanisms by which both biomass and cigarette smoke exposure cause lung damage may be similar. Copyright: © 2013 Krimmer et a

    Once only principle: Benefits, barriers & next steps

    Get PDF
    The Once-Once Principle (OOP) suggests that citizens and businesses should have the right to supply information only once to a public administration. It would then be the responsibility of public administration offices to take all necessary actions in order to internally share this data by respecting the relevant data protection rules. The overall aim is to reduce administrative burden. The implementation of the OOP is high on the political agenda of many countries including the Member States of the European Union. The aim of this panel is to enable an open discussion between the panelists and the audience in order to exchange good practices and also identify and prioritize benefits and barriers as well as possible next steps towards widely implementing the once only principle in public service provisioning

    Backward Compatibility Effects in Younger and Older Adults

    Get PDF
    In many dual-task situations, responses to the second of two tasks are slowed when the time between tasks is short. The response-selection bottleneck model of dual-task performance accounts for this phenomenon by assuming that central processing of the second task is blocked by a bottleneck until central processing of Task 1 is complete. This assumption could be called into question if it could be demonstrated that the response to Task 2 affected the central processing of Task 1, a backward response compatibility effect. Such effects are well-established in younger adults. Backward compatibility effects in older (as well as younger) adults were explored in two experiments. The first experiment found clear backward response compatibility effects for younger adults but no evidence of them for older adults. The second experiment explored backward stimulus compatibility and found similar effects in both younger and older adults. Evidence possibly consistent with some pre-bottleneck processing of Task 2 central stages also was found in the second experiment in both age groups. For younger adults, the results provide further evidence falsifying the claim of an immutable response selection bottleneck. For older adults, the evidence suggested that Task 2 affects Task 1 when there is stimulus compatibility but not when there is response compatibility

    Comparison of two analysis methods for nuclear reaction measurements of 12C +12C interactions at 95 MeV/u for hadrontherapy

    Get PDF
    During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than (±\pm3% and±\pm1 mm). Therefore, measurements are performed to determine the double differential cross section for different reactions. In this paper, the analysis of data from 12C +12C reactions at 95 MeV/u are presented. The emitted particles are detected with \DeltaEthin-\DeltaEthick-E telescopes made of a stack of two silicon detectors and a CsI crystal. Two different methods are used to identify the particles. One is based on graphical cuts onto the \DeltaE-E maps, the second is based on the so-called KaliVeda method using a functional description of \DeltaE versus E. The results of the two methods will be presented in this paper as well as the comparison between both

    Instrumentation pour le suivi en ligne des traitements par hadronthérapie

    Get PDF
    National audienceInstrumentation for on-line monitoring of hadrontherapy treatments Localization of the dose deposited in the patient is a key point for the hadrontherapy cancer treatment. Different modalities of on-line control are explored, motivating acquisition systems and detectors developments, such as a Compton gamma camera, a proton trajectometer and a beam hodoscope

    A portable 3D Imaging FMCW MIMO Radar Demonstrator with a 24x24 Antenna Array for Medium Range Applications

    Full text link
    © 2018 IEEE. Personal use of this material is permitted. Permissíon from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertisíng or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.[EN] Multiple-input multiple-output (MIMO) radars have been shown to improve target detection for surveillance applications thanks to their proven high-performance properties. In this paper, the design, implementation, and results of a complete 3-D imaging frequency-modulated continuous-wave MIMO radar demonstrator are presented. The radar sensor working frequency range spans between 16 and 17 GHz, and the proposed solution is based on a 24-transmitter and 24-receiver MIMO radar architecture, implemented by timedivision multiplexing of the transmit signals. A modular approach based on conventional low-cost printed circuit boards is used for the transmit and receive systems. Using digital beamforming algorithms and radar processing techniques on the received signals, a high-resolution 3-D sensing of the range, azimuth, and elevation can be calculated. With the current antenna configuration, an angular resolution of 2.9° can be reached. Furthermore, by taking advantage of the 1-GHz bandwidth of the system, a range resolution of 0.5 m is achieved. The radio-frequency front-end, digital system and radar signal processing units are here presented. The medium-range surveillance potential and the high-resolution capabilities of the MIMO radar are proved with results in the form of radar images captured from the field measurements.Ganis, A.; Miralles-Navarro, E.; Schoenlinner, B.; Prechtel, U.; Meusling, A.; Heller, C.; Spreng, T.... (2018). A portable 3D Imaging FMCW MIMO Radar Demonstrator with a 24x24 Antenna Array for Medium Range Applications. IEEE Transactions on Geoscience and Remote Sensing. 56(1):298-312. https://doi.org/10.1109/TGRS.2017.2746739S29831256

    The helicity amplitudes A1/2_{1/2} and A3/2_{3/2} for the D13(1520)_{13}(1520) resonance obtained from the γ⃗p⃗→pπ0\vec{\gamma} \vec{p} \to p \pi^0 reaction}

    Full text link
    The helicity dependence of the γ⃗p⃗→pπ0\vec{\gamma} \vec{p} \to p \pi^0 reaction has been measured for the first time in the photon energy range from 550 to 790 MeV. The experiment, performed at the Mainz microtron MAMI, used a 4π\pi-detector system, a circularly polarized, tagged photon beam, and a longitudinally polarized frozen-spin target. These data are predominantly sensitive to the D13(1520)D_{13}(1520) resonance and are used to determine its parameters.Comment: 5 pages, 4 figure

    First measurement of the Gerasimov-Drell-Hearn integral for Hydrogen from 200 to 800 MeV

    Full text link
    A direct measurement of the helicity dependence of the total photoabsorption cross section on the proton was carried out at MAMI (Mainz) in the energy range 200 < E_gamma < 800 MeV. The experiment used a 4π\pi detection system, a circularly polarized tagged photon beam and a frozen spin target. The contributions to the Gerasimov-Drell-Hearn sum rule and to the forward spin polarizability Îł0\gamma_0 determined from the data are 226 \pm 5 (stat)\pm 12(sys) \mu b and -187 \pm 8 (stat)\pm 10(sys)10^{-6} fm^4, respectively, for 200 < E_\gamma < 800 MeV.Comment: 6 pages, 3 figures, 3 table
    • 

    corecore