4,587 research outputs found

    The REFER (REFer for EchocaRdiogram) protocol: a prospective validation of a clinical decision rule, NT-proBNP, or their combination, in the diagnosis of heart failure in primary care. Rationale and design.

    Get PDF
    BACKGROUND: Heart failure is a major cause of mortality and morbidity. As mortality rates are high, it is important that patients seen by general practitioners with symptoms suggestive of heart failure are identified quickly and treated appropriately. Identifying patients with heart failure or deciding which patients need further tests is a challenge. All patients with suspected heart failure should be diagnosed using objective tests such as echocardiography, but it is expensive, often delayed, and limited by the significant skill shortage of trained echocardiographers. Alternative approaches for diagnosing heart failure are currently limited. Clinical decision tools that combine clinical signs, symptoms or patient characteristics are designed to be used to support clinical decision-making and validated according to strict methodological procedures. The REFER Study aims to determine the accuracy and cost-effectiveness of our previously derived novel, simple clinical decision rule, a natriuretic peptide assay, or their combination, in the triage for referral for echocardiography of symptomatic adult patients who present in general practice with symptoms suggestive of heart failure. METHODS/DESIGN: This is a prospective, Phase II observational, diagnostic validation study of a clinical decision rule, natriuretic peptides or their combination, for diagnosing heart failure in primary care. Consecutive adult primary care patients 55 years of age or over presenting to their general practitioner with a chief complaint of recent new onset shortness of breath, lethargy or peripheral ankle oedema of over 48 hours duration, with no obvious recurrent, acute or self-limiting cause will be enrolled. Our reference standard is based upon a three step expert specialist consensus using echocardiography and clinical variables and tests. DISCUSSION: Our clinical decision rule offers a potential solution to the diagnostic challenge of providing a timely and accurate diagnosis of heart failure in primary care. Study results will provide an evidence-base from which to develop heart failure care pathway recommendations and may be useful in standardising care. If demonstrated to be effective, the clinical decision rule will be of interest to researchers, policy makers and general practitioners worldwide. TRIAL REGISTRATION: ISRCTN17635379.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are

    Primary care REFerral for EchocaRdiogram (REFER) in heart failure: a diagnostic accuracy study.

    Get PDF
    BACKGROUND: Symptoms of breathlessness, fatigue, and ankle swelling are common in general practice but deciding which patients are likely to have heart failure is challenging. AIM: To evaluate the performance of a clinical decision rule (CDR), with or without N-Terminal pro-B type natriuretic peptide (NT-proBNP) assay, for identifying heart failure. DESIGN AND SETTING: Prospective, observational, diagnostic validation study of patients aged >55 years, presenting with shortness of breath, lethargy, or ankle oedema, from 28 general practices in England. METHOD: The outcome was test performance of the CDR and natriuretic peptide test in determining a diagnosis of heart failure. The reference standard was an expert consensus panel of three cardiologists. RESULTS: Three hundred and four participants were recruited, with 104 (34.2%; 95% confidence interval [CI] = 28.9 to 39.8) having a confirmed diagnosis of heart failure. The CDR+NT-proBNP had a sensitivity of 90.4% (95% CI = 83.0 to 95.3) and specificity 45.5% (95% CI = 38.5 to 52.7). NT-proBNP level alone with a cut-off <400 pg/ml had sensitivity 76.9% (95% CI = 67.6 to 84.6) and specificity 91.5% (95% CI = 86.7 to 95.0). At the lower cut-off of NT-proBNP <125 pg/ml, sensitivity was 94.2% (95% CI = 87.9 to 97.9) and specificity 49.0% (95% CI = 41.9 to 56.1). CONCLUSION: At the low threshold of NT-proBNP <125 pg/ml, natriuretic peptide testing alone was better than a validated CDR+NT-proBNP in determining which patients presenting with symptoms went on to have a diagnosis of heart failure. The higher NT-proBNP threshold of 400 pg/ml may mean more than one in five patients with heart failure are not appropriately referred. Guideline natriuretic peptide thresholds may need to be revised

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Shades of empire: police photography in German South-West Africa

    Get PDF
    This article looks at a photographic album produced by the German police in colonial Namibia just before World War I. Late 19th- and early 20th-century police photography has often been interpreted as a form of visual production that epitomized power and regimes of surveillance imposed by the state apparatuses on the poor, the criminal and the Other. On the other hand police and prison institutions became favored sites where photography could be put at the service of the emergent sciences of the human body—physiognomy, anthropometry and anthropology. While the conjuncture of institutionalized colonial state power and the production of scientific knowledge remain important for this Namibian case study, the article explores a slightly different set of questions. Echoing recent scholarship on visuality and materiality the photographic album is treated as an archival object and visual narrative that was at the same time constituted by and constitutive of material and discursive practices within early 20th-century police and prison institutions in the German colony. By shifting attention away from image content and visual codification alone toward the question of visual practice the article traces the ways in which the photo album, with its ambivalent, unstable and uncontained narrative, became historically active and meaningful. Therein the photographs were less informed by an abstract theory of anthropological and racial classification but rather entrenched with historically contingent processes of colonial state constitution, socioeconomic and racial stratification, and the institutional integration of photography as a medium and a technology into colonial policing. The photo album provides a textured sense of how fragmented and contested these processes remained throughout the German colonial period, but also how photography could offer a means of transcending the limits and frailties brought by the realities on the ground.International Bibliography of Social Science

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for the standard model Higgs boson in the H to ZZ to 2l 2nu channel in pp collisions at sqrt(s) = 7 TeV

    Get PDF
    A search for the standard model Higgs boson in the H to ZZ to 2l 2nu decay channel, where l = e or mu, in pp collisions at a center-of-mass energy of 7 TeV is presented. The data were collected at the LHC, with the CMS detector, and correspond to an integrated luminosity of 4.6 inverse femtobarns. No significant excess is observed above the background expectation, and upper limits are set on the Higgs boson production cross section. The presence of the standard model Higgs boson with a mass in the 270-440 GeV range is excluded at 95% confidence level.Comment: Submitted to JHE

    Combined search for the quarks of a sequential fourth generation

    Get PDF
    Results are presented from a search for a fourth generation of quarks produced singly or in pairs in a data set corresponding to an integrated luminosity of 5 inverse femtobarns recorded by the CMS experiment at the LHC in 2011. A novel strategy has been developed for a combined search for quarks of the up and down type in decay channels with at least one isolated muon or electron. Limits on the mass of the fourth-generation quarks and the relevant Cabibbo-Kobayashi-Maskawa matrix elements are derived in the context of a simple extension of the standard model with a sequential fourth generation of fermions. The existence of mass-degenerate fourth-generation quarks with masses below 685 GeV is excluded at 95% confidence level for minimal off-diagonal mixing between the third- and the fourth-generation quarks. With a mass difference of 25 GeV between the quark masses, the obtained limit on the masses of the fourth-generation quarks shifts by about +/- 20 GeV. These results significantly reduce the allowed parameter space for a fourth generation of fermions.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore