388 research outputs found
Resonance Effects in the Nonadiabatic Nonlinear Quantum Dimer
The quantum nonlinear dimer consisting of an electron shuttling between the
two sites and in weak interaction with vibrations, is studied numerically under
the application of a DC electric field. A field-induced resonance phenomenon
between the vibrations and the electronic oscillations is found to influence
the electronic transport greatly. For initially delocalization of the electron,
the resonance has the effect of a dramatic increase in the transport. Nonlinear
frequency mixing is identified as the main mechanism that influences transport.
A characterization of the frequency spectrum is also presented.Comment: 7 pages, 6 figure
Tri-meson-mixing of -- and -- in the light-cone quark model
The radiative transition form factors of the pseudoscalar mesons {,
, } and the vector mesons {, , } are restudied
with -- and -- in tri-meson-mixing
pattern, which is described by tri-mixing matrices in the light-cone
constituent quark model. The experimental transition decay widths are better
reproduced with tri-meson-mixing than previous results in a two-mixing-angle
scenario of only two-meson - mixing and - mixing.Comment: 8 pages, 6 figures, final version to appear in EPJ
The Quest for Antiinflammatory and Immunomodulatory Strategies in Heart Failure
Intensive research over the last 3 decades has unequivocally demonstrated the relevance of inflammation in heart failure (HF). Despite our current and ever increasing knowledge about inflammation, the clinical success of antiinflammatory and immunomodulatory therapies in HF is still limited. This review outlines the complexity and diversity of inflammation, its reciprocal interaction with HF, and addresses future perspectives, calling for immunomodulatory therapies that are specific for factors that activate the immune system without the risk of nonspecific immune suppression
An integrative knowledge management framework to support ERP implementation for improved management decision making in industry
Young and Intermediate-age Distance Indicators
Distance measurements beyond geometrical and semi-geometrical methods, rely
mainly on standard candles. As the name suggests, these objects have known
luminosities by virtue of their intrinsic proprieties and play a major role in
our understanding of modern cosmology. The main caveats associated with
standard candles are their absolute calibration, contamination of the sample
from other sources and systematic uncertainties. The absolute calibration
mainly depends on their chemical composition and age. To understand the impact
of these effects on the distance scale, it is essential to develop methods
based on different sample of standard candles. Here we review the fundamental
properties of young and intermediate-age distance indicators such as Cepheids,
Mira variables and Red Clump stars and the recent developments in their
application as distance indicators.Comment: Review article, 63 pages (28 figures), Accepted for publication in
Space Science Reviews (Chapter 3 of a special collection resulting from the
May 2016 ISSI-BJ workshop on Astronomical Distance Determination in the Space
Age
Manifesto of computational social science
The increasing integration of technology into our lives has created unprecedented volumes of data on society's everyday behaviour. Such data opens up exciting new opportunities to work towards a quantitative understanding of our complex social systems, within the realms of a new discipline known as Computational Social Science. Against a background of financial crises, riots and international epidemics, the urgent need for a greater comprehension of the complexity of our interconnected global society and an ability to apply such insights in policy decisions is clear. This manifesto outlines the objectives of this new scientific direction, considering the challenges involved in it, and the extensive impact on science, technology and society that the success of this endeavour is likely to bring about.The publication of this work was partially supported by the European Union’s Seventh Framework Programme (FP7/2007–2013) under grant agreement No. 284709, a Coordination and Support Action in the Information and Communication Technologies activity area (‘FuturICT’ FET Flagship Pilot Project). We are grateful to the anonymous reviewers for the insightful comments.Publicad
Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory
The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data
Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET
The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR
On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection
A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)
The rapid atmospheric monitoring system of the Pierre Auger Observatory
The Pierre Auger Observatory is a facility built to detect air showers produced by cosmic rays above 10(17) eV. During clear nights with a low illuminated moon fraction, the UV fluorescence light produced by air showers is recorded by optical telescopes at the Observatory. To correct the observations for variations in atmospheric conditions, atmospheric monitoring is performed at regular intervals ranging from several minutes (for cloud identification) to several hours (for aerosol conditions) to several days (for vertical profiles of temperature, pressure, and humidity). In 2009, the monitoring program was upgraded to allow for additional targeted measurements of atmospheric conditions shortly after the detection of air showers of special interest, e. g., showers produced by very high-energy cosmic rays or showers with atypical longitudinal profiles. The former events are of particular importance for the determination of the energy scale of the Observatory, and the latter are characteristic of unusual air shower physics or exotic primary particle types. The purpose of targeted (or 'rapid') monitoring is to improve the resolution of the atmospheric measurements for such events. In this paper, we report on the implementation of the rapid monitoring program and its current status. The rapid monitoring data have been analyzed and applied to the reconstruction of air showers of high interest, and indicate that the air fluorescence measurements affected by clouds and aerosols are effectively corrected using measurements from the regular atmospheric monitoring program. We find that the rapid monitoring program has potential for supporting dedicated physics analyses beyond the standard event reconstruction
- …
