84 research outputs found

    Open Courseware vs. Open Source Software - A Critical Comparison

    Get PDF
    The Massachusetts Institute of Technology (MIT) recently announced its OpenCourseWare project, which will make all its courseware available on the Internet free of charge. This paper compares the OpenCourseWare project to the open source approach of software development. It contrasts and evaluates the nature of the products, the motives of the producers and users, the consequences on the market environment and the contribution to the scientific progress. Besides exploring the specific MIT case, another motivation of the paper is to stimulate the academic discussion about new regimes for dealing with digital courseware

    Blood lead levels in 2018/2019 compared to 1987/1988 in the German population-based KORA study

    Get PDF
    INTRODUCTION: Lead exposure remains of continuing concern due to its known and suspected impacts on human health and has been designated as a priority substance for investigation in human biomonitoring studies by the EU. The aims of this study were to measure blood lead levels (BLL) in a population based cohort of middle-aged individuals without major current exposures to lead, and to compare these to historical blood lead levels obtained thirty years earlier. METHODS: The population-based KORA study from 1984 to 2001 included inhabitants of the Augsburg Region, Germany. During 2018 to 2019, a subsample of these participants (KORA-Fit) was invited for interview regarding demographic and lifestyle factors, physical examination and blood withdrawal. Blood samples were stored at -80C prior to measurement of BLL via graphite furnace atomic absorption spectroscopy (GF-AAS). Descriptive and multivariable analyses were performed. RESULTS: BLLs were measured in 3033 eligible persons aged 54 to 73, establishing a geometric mean (GM) BLL of 24.8 μg/l in 2018/19. Of these, 555 (18%) had BLL above proposed 95th percentile reference values of the German Environment Agency. Only small differences were found in BLL stratified by sociodemographic categories, however regular smokers had higher GM BLL (26.1 μg/l) compared to never smokers (23.7 μg/l), and an increasing BLL with increased wine consumption was noted. For 556 individuals, BLLs (GM: 54.0 μg/l) reduced by 35% in men and 50% in women compared to levels in 1987/88 with only 1.4% of individuals having an unchanged or increased BLL. DISCUSSION: KORA-Fit provided contemporary normative data for BLL in a Western European population without major current sources of lead exposure. Mean BLLs have fallen since the 1980s using historical BLL data which is likely linked to the ban of leaded gasoline. Nevertheless, BLLs in this population remain elevated at levels associated with morbidity and mortality

    Reference values of impulse oscillometric lung function indices in adults of advanced age.

    Get PDF
    Impulse oscillometry (IOS) is a non-demanding lung function test. Its diagnostic use may be particularly useful in patients of advanced age with physical or mental limitations unable to perform spirometry. Only few reference equations are available for Caucasians, none of them covering the old age. Here, we provide reference equations up to advanced age and compare them with currently available equations. IOS was performed in a population-based sample of 1990 subjects, aged 45-91 years, from KORA cohorts (Augsburg, Germany). From those, 397 never-smoking, lung healthy subjects with normal spirometry were identified and sex-specific quantile regression models with age, height and body weight as predictors for respiratory system impedance, resistance, reactance, and other parameters of IOS applied. Women (n = 243) showed higher resistance values than men (n = 154), while reactance at low frequencies (up to 20 Hz) was lower (p<0.05). A significant age dependency was observed for the difference between resistance values at 5 Hz and 20 Hz (R5-R20), the integrated area of low-frequency reactance (AX), and resonant frequency (Fres) in both sexes whereas reactance at 5 Hz (X5) was age dependent only in females. In the healthy subjects (n = 397), mean differences between observed values and predictions for resistance (5 Hz and 20 Hz) and reactance (5 Hz) ranged between -1% and 5% when using the present model. In contrast, differences based on the currently applied equations (Vogel & Smidt 1994) ranged between -34% and 76%. Regarding our equations the indices were beyond the limits of normal in 8.1% to 18.6% of the entire KORA cohort (n = 1990), and in 0.7% to 9.4% with the currently applied equations. Our study provides up-to-date reference equations for IOS in Caucasians aged 45 to 85 years. We suggest the use of the present equations particularly in advanced age in order to detect airway dysfunction

    The performance of irradiated CMS silicon mirco-strip detector modules

    Get PDF
    The central tracking system of the Compact Muon Solenoid (CMS) experiment will be entirely buil in silicon technology. The majority of the CMS tracker consists of silicon micro-strip detectors which have to be operated in the harsh environment of the Large Hadron Collider (LHC) over a period of ten years. The expected equivalent fluences range from a low of 0.7 x 10^14 n_1MeV/cm^2 at the outermost layers of the tracker, to a high of 1.6 x 10^14 n_1MeV/cm^2 at the layers closest to the interaction region. In this paper, results from studies of irradiatied CMS silicon detector modules are presented

    Reception Test of Petals for the End Cap TEC+ of the CMS Silicon Strip Tracker

    Get PDF
    The silicon strip tracker of the CMS experiment has been completed and was inserted into the CMS detector in late 2007. The largest sub system of the tracker are its end caps, comprising two large end caps (TEC) each containing 3200 silicon strip modules. To ease construction, the end caps feature a modular design: groups of about 20 silicon modules are placed on sub-assemblies called petals and these self-contained elements are then mounted onto the TEC support structures. Each end cap consists of 144 such petals, which were built and fully qualified by several institutes across Europe. Fro

    Integration of the End Cap TEC+ of the CMS Silicon Strip Tracker

    Get PDF
    The silicon strip tracker of the CMS experiment has been completed and inserted into the CMS detector in late 2007. The largest sub-system of the tracker is its end cap system, comprising two large end caps (TEC) each containing 3200 silicon strip modules. To ease construction, the end caps feature a modular design: groups of about 20 silicon modules are placed on sub-assemblies called petals and these self-contained elements are then mounted into the TEC support structures. Each end cap consists of 144 petals, and the insertion of these petals into the end cap structure is referred to as TEC integration. The two end caps were integrated independently in Aachen (TEC+) and at CERN (TEC--). This note deals with the integration of TEC+, describing procedures for end cap integration and for quality control during testing of integrated sections of the end cap and presenting results from the testing

    Framework and baseline examination of the German National Cohort (NAKO)

    Get PDF
    The German National Cohort (NAKO) is a multidisciplinary, population-based prospective cohort study that aims to investigate the causes of widespread diseases, identify risk factors and improve early detection and prevention of disease. Specifically, NAKO is designed to identify novel and better characterize established risk and protection factors for the development of cardiovascular diseases, cancer, diabetes, neurodegenerative and psychiatric diseases, musculoskeletal diseases, respiratory and infectious diseases in a random sample of the general population. Between 2014 and 2019, a total of 205,415 men and women aged 19–74 years were recruited and examined in 18 study centres in Germany. The baseline assessment included a face-to-face interview, self-administered questionnaires and a wide range of biomedical examinations. Biomaterials were collected from all participants including serum, EDTA plasma, buffy coats, RNA and erythrocytes, urine, saliva, nasal swabs and stool. In 56,971 participants, an intensified examination programme was implemented. Whole-body 3T magnetic resonance imaging was performed in 30,861 participants on dedicated scanners. NAKO collects follow-up information on incident diseases through a combination of active follow-up using self-report via written questionnaires at 2–3 year intervals and passive follow-up via record linkages. All study participants are invited for re-examinations at the study centres in 4–5 year intervals. Thereby, longitudinal information on changes in risk factor profiles and in vascular, cardiac, metabolic, neurocognitive, pulmonary and sensory function is collected. NAKO is a major resource for population-based epidemiology to identify new and tailored strategies for early detection, prediction, prevention and treatment of major diseases for the next 30 years. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10654-022-00890-5

    Excitonic channels from bio-inspired templated supramolecular assembly of J-aggregate nanowires

    Get PDF
    Supramolecular assemblies with controlled morphology are of paramount importance for energy transport in organic semiconductors. Despite considerable freedom in molecular design, the preparation of dyes that form one dimensional J-aggregates is challenging. Here, we demonstrate a simple and effective route to functionalize dendronized polymers (DPs) with J-aggregates to construct tubular DP/J-aggregate nanowires. When J-aggregates are adsorbed onto DPs anchored to glass substrates, they assemble into microcrystalline domains typical for J-aggregates adsorbed on functionalized surfaces. Differently, the complexation between the dendronized polymer and J-aggregates in solution leads to dense packing of J-aggregate strands on the periphery of the DPs. Using a layer-by-layer (LBL) technique, DPs loaded with J-aggregates can also be adsorbed onto a DP monolayer. In this case, the thin film absorption spectra are narrower and indicate higher ratios of J-aggregate to monomer and dimer absorption than bare J-aggregates deposited similarly. The demonstration of J-aggregate adsorption on filamentous polymeric templates is a promising step toward artificial 1D light harvesting antennas, with potential applications in opto-electronic devices

    Neuroimaging standards for research into small vessel disease and its contribution to ageing and neurodegeneration: A united approach

    Get PDF
    Item does not contain fulltextCerebral small vessel disease (SVD) is a common accompaniment of ageing. Features seen on neuroimaging include recent small subcortical infarcts, lacunes, white matter hyperintensities, perivascular spaces, microbleeds, and brain atrophy. SVD can present as a stroke or cognitive decline, or can have few or no symptoms. SVD frequently coexists with neurodegenerative disease, and can exacerbate cognitive deficits, physical disabilities, and other symptoms of neurodegeneration. Terminology and definitions for imaging the features of SVD vary widely, which is also true for protocols for image acquisition and image analysis. This lack of consistency hampers progress in identifying the contribution of SVD to the pathophysiology and clinical features of common neurodegenerative diseases. We are an international working group from the Centres of Excellence in Neurodegeneration. We completed a structured process to develop definitions and imaging standards for markers and consequences of SVD. We aimed to achieve the following: first, to provide a common advisory about terms and definitions for features visible on MRI; second, to suggest minimum standards for image acquisition and analysis; third, to agree on standards for scientific reporting of changes related to SVD on neuroimaging; and fourth, to review emerging imaging methods for detection and quantification of preclinical manifestations of SVD. Our findings and recommendations apply to research studies, and can be used in the clinical setting to standardise image interpretation, acquisition, and reporting. This Position Paper summarises the main outcomes of this international effort to provide the STandards for ReportIng Vascular changes on nEuroimaging (STRIVE)

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    • …
    corecore