481 research outputs found

    Edoxaban vs. warfarin in patients with atrial fibrillation on amiodarone: a subgroup analysis of the ENGAGE AF-TIMI 48 trial

    Get PDF
    Background In the ENGAGE AF-TIMI 48 trial, the higher-dose edoxaban (HDE) regimen had a similar incidence of ischaemic stroke compared with warfarin, whereas a higher incidence was observed with the lower-dose regimen (LDE). Amiodarone increases edoxaban plasma levels via P-glycoprotein inhibition. The current pre-specified exploratory analysis was performed to determine the effect of amiodarone on the relative efficacy and safety profile of edoxaban. Methods and results At randomization, 2492 patients (11.8%) were receiving amiodarone. The primary efficacy endpoint of stroke or systemic embolic event was significantly lower with LDE compared with warfarin in amiodarone treated patients vs. patients not on amiodarone (hazard ratio [HR] 0.60, 95% confidence intervals [CIs] 0.36-0.99 and HR 1.20, 95% CI 1.03-1.40, respectively; P interaction <0.01). In patients randomized to HDE, no such interaction for efficacy was observed (HR 0.73, 95% CI 0.46-1.17 vs. HR 0.89, 95% CI 0.75-1.05, P interaction = 0.446). Major bleeding was similar in patients on LDE (HR 0.35, 95% CI 0.21-0.59 vs. HR 0.53, 95% CI 0.46-0.61, P interaction = 0.131) and HDE (HR 0.94, 95% CI 0.65-1.38 vs. HR 0.79, 95% CI 0.69-0.90, P interaction = 0.392) when compared with warfarin, independent of amiodarone use. Conclusions Patients randomized to the LDE treated with amiodarone at the time of randomization demonstrated a significant reduction in ischaemic events vs. warfarin when compared with those not on amiodarone, while preserving a favourable bleeding profile. In contrast, amiodarone had no effect on the relative efficacy and safety of HD

    Repetitive out of hospital cardiac arrests following pregnancy: A case report of an unfortunate presentation of mitral annular disjunction

    Get PDF
    Background Mitral annular disjunction (MAD) is an under-recognized cause of arrhythmic sudden cardiac death, especially in young women. The relation between MAD and the occurrence of arrhythmia during pregnancy has not yet been explored. We would like to stress the importance of careful echocardiographic examination and the vulnerable peripartum period. ................................................................................................................................................................................................... Case summary A 29-year-old woman survived an out of hospital cardiac arrest 4 months after delivery of her first child. The diagnosis was not clear and an implantable cardioverter-defibrillator (ICD) as secondary prevention was implanted. Her second pregnancy and delivery were uneventful. The 12-lead electrocardiogram demonstrated sinus rhythm with right bundle branch block, ventricular extra systoles (premature ventricular contractions), and a right superior axis, i.e. origin in the inferolateral basal left ventricle. Transthoracic 2D echocardiography showed myxomatous mitral valve disease with moderate mitral valve insufficiency with normal left and right heart dimensions and function. However, 4 weeks after delivery she experienced a sudden syncope at home. Implantable cardioverter-defibrillator reading revealed primary ventricular fibrillation, induced by a ventricular premature beat (VPB), terminated with a successful ICD shock. A frame-by-frame echocardiographic analysis of the mitral valve using biplane echocardiographic analysis allowed diagnosis of MAD with detachment of the root of the annulus from the posterolateral ventricular myocardium during systole. ................................................................................................................................................................................................... Conclusion Mitral annular disjunction is an under-recognized cause of arrhythmic sudden cardiac death. Biplane echocardiographic analysis of the mitral annulus can identify MAD and as such may help for risk stratification and sudden cardiac death prevention. Careful follow-up is necessary especially during pregnancy and the postpartum period

    International criteria for electrocardiographic interpretation in athletes: Consensus statement.

    Get PDF
    Sudden cardiac death (SCD) is the leading cause of mortality in athletes during sport. A variety of mostly hereditary, structural or electrical cardiac disorders are associated with SCD in young athletes, the majority of which can be identified or suggested by abnormalities on a resting 12-lead electrocardiogram (ECG). Whether used for diagnostic or screening purposes, physicians responsible for the cardiovascular care of athletes should be knowledgeable and competent in ECG interpretation in athletes. However, in most countries a shortage of physician expertise limits wider application of the ECG in the care of the athlete. A critical need exists for physician education in modern ECG interpretation that distinguishes normal physiological adaptations in athletes from distinctly abnormal findings suggestive of underlying pathology. Since the original 2010 European Society of Cardiology recommendations for ECG interpretation in athletes, ECG standards have evolved quickly, advanced by a growing body of scientific data and investigations that both examine proposed criteria sets and establish new evidence to guide refinements. On 26-27 February 2015, an international group of experts in sports cardiology, inherited cardiac disease, and sports medicine convened in Seattle, Washington (USA), to update contemporary standards for ECG interpretation in athletes. The objective of the meeting was to define and revise ECG interpretation standards based on new and emerging research and to develop a clear guide to the proper evaluation of ECG abnormalities in athletes. This statement represents an international consensus for ECG interpretation in athletes and provides expert opinion-based recommendations linking specific ECG abnormalities and the secondary evaluation for conditions associated with SCD

    Cardiovascular pre-participation screening of young competitive athletes for prevention of sudden death: proposal for a common European protocol: Consensus Statement of the Study Group of Sport Cardiology of the Working Group of Cardiac Rehabilitation and Exercise Physiology and the Working Group of Myocardial and Pericardial Diseases of the European Society of Cardiology

    Get PDF
    he 1996 American Heart Association consensus panel recommendations stated that pre-participation cardiovascular screening for young competitive athletes is justifiable and compelling on ethical, legal, and medical grounds. The present article represents the consensus statement of the Study Group on Sports Cardiology of the Working Group on Cardiac Rehabilitation and Exercise Physiology and the Working Group on Myocardial and Pericardial diseases of the European Society of Cardiology, which comprises cardiovascular specialists and other physicians from different European countries with extensive clinical experience with young competitive athletes, as well as with pathological substrates of sudden death. The document takes note of the 25-year Italian experience on systematic pre-participation screening of competitive athletes and focuses on relevant issues, mostly regarding the relative risk, causes, and prevalence of sudden death in athletes; the efficacy, feasibility, and cost-effectiveness of population-based pre-participation cardiovascular screening; the key role of 12-lead ECG for identification of cardiovascular diseases such as cardiomyopathies and channelopathies at risk of sudden death during sports; and the potential of preventing fatal events. The main purpose of the consensus document is to reinforce the principle of the need for pre-participation medical clearance of all young athletes involved in organized sports programmes, on the basis of (i) the proven efficacy of systematic screening by 12-lead ECG (in addition to history and physical examination) to identify hypertrophic cardiomyopathy-the leading cause of sports-related sudden death-and to prevent athletic field fatalities; (ii) the potential screening ability in detecting other lethal cardiovascular diseases presenting with ECG abnormalities. The consensus document recommends the implementation of a common European screening protocol essentially based on 12-lead ECG

    State of play and future direction with NOACs: An expert consensus.

    Get PDF
    Atrial fibrillation (AF) and venous thromboembolism (VTE) are cardiovascular conditions significant in contemporary practice. In both, the use of anticoagulation with vitamin K antagonists (VKAs) has been traditionally used to prevent adverse events. However, VKA therapy is associated with challenges relating to dose maintenance, the need to monitor anticoagulation, and bleeding risks. The non-vitamin K oral anticoagulants (NOACs) are becoming accepted as a clear alternative to VKA therapy for both AF and VTE management. The aim of this paper was to review contemporary evidence on the safety of NOACs in both conditions. A comprehensive literature review was conducted to explore key safety issues and expert consensus was achieved from eight professionals specialised in AF and VTE care. Consensus-based statements were formulated where available evidence was weak or contradictory. The expert statements in this paper form a key overview of the safety of NOACs compared with VKA therapy, and the comparative safety of different NOACs. It is apparent that a detailed patient work-up is required in order to identify and manage individual risk factors for bleeding and thrombosis prior to NOAC therapy. Additional measures, such as dose reductions, may also be used to maintain the safety of NOACs in practice

    Acute success and short-term follow-up of catheter ablation of isthmus-dependent atrial flutter; a comparison of 8 mm tip radiofrequency and cryothermy catheters

    Get PDF
    Objectives: To compare the acute success and short-term follow-up of ablation of atrial flutter using 8 mm tip radiofrequency (RF) and cryocatheters. Methods: Sixty-two patients with atrial flutter were randomized to RF or cryocatheter (cryo) ablation. Right atrial angiography was performed to assess the isthmus. End point was bidirectional isthmus block on multiple criteria. A pain score was used and the analgesics were recorded. Patients were followed for at least 3 months. Results: The acute success rate for RF was 83% vs 69% for cryo (NS). Procedure times were similar (mean 144±48 min for RF, vs 158±49 min for cryo). More applications were given with RF than with cryo (26±17 vs. 18±10, p<0.05). Fluoroscopy time was longer with RF (29±15 vs. 19±12 min, p<0.02). Peak CK, CK-MB and CK-MB mass were higher, also after 24 h in the cryo group. Troponin T did not differ. Repeated transient block during application (usually with cryoablation) seemed to predict failure. Cryothermy required significantly less analgesia (p<0.01), and no use of long sheaths (p<0.005). The isthmus tended to be longer in the failed procedures (p=0.117). This was similar for both groups, as was the distribution of anatomic variations. Recurrences and complaints in the successful patients were similar for both groups, with a very low recurrence of atrial flutter after initial success. Concl

    Radiation protection value to the operator from augmented reality smart glasses in interventional fluoroscopy procedures using phantoms

    Get PDF
    Introduction: Smart glasses can be adapted to display radiographic images to allow clinician’s gaze not to be directionally fixed or predetermined by computer monitor location. This study presents an analysis of eye lens dose during interventional fluoroscopy guided procedures, comparing fixed monitor positions against the use of smart glasses. Methods: Using a head phantom (simulating the clinician), thermoluminescent dosimeters and lead shielded glasses, the dose to the eye was measured for different head ‘rotations and tilts’ for: gaze directed towards the main scattering source (patient / primary beam) to represent potential gaze direction if smart glasses are used; gaze directed to a range of potential computer monitor positions. An anthropomorphic pelvis phantom was utilised to simulate the patient. Accumulated dose rates (µGy.sˉ¹) from five 10-second exposures at 75 kV 25.2 mAs were recorded. Results: An average DAP reading of 758.84 cGy.cm2 was measured during each 10 second exposure. Whilst wearing lead shielded glasses a 6.10 – fold reduction in dose rate to the lens is possible (p&lt;0.05). Influence of the direction of gaze by the clinician demonstrated a wide range of dose rate reduction from 3.13% (p=0.16) to 143.69% (p&lt;0.05) when the clinician’s gaze was towards the main scattering source. Increased dose rate to the clinician’s eyes was received despite wearing lead shielded glasses, as the angle of gaze moved 45º and 90º from 0º. Conclusion: If the clinician’s gaze is directed towards the main scattering source a potential exists for reducing eye lens dose compared with fixed location computer monitors. Introduction of lead lined smart glasses into interventional radiology may lead to improvements in patient care, reducing the need for the clinician to look away from the patient to observe a radiographic image
    • …
    corecore