5,250 research outputs found

    Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring

    Get PDF
    IEEE 802.15.4/ZigBee wireless sensor networks (WSNs) are a promising alternative to cabled systems for patient monitoring in hospitals. Some areas where monitoring systems based on WSNs can be successfuly used are ambulatory, waiting and triage rooms, post-op, and emergency rooms. The low power and small size ZigBee devices have the ability to form self-configuring networks that can extend themselves through a hospital wing or floor. Using spatially distributed networks, it is possible to cover an extended area and serve several patients. However, the low data rate protocols provided by IEEE 802.15.4 poses several challenges, mainly because its protocols were primarily designed to operate in low traffic load scenarios but some vital signs sensors generate a large volume of data. This work presents an experimental evaluation of the performance of multi-hop ZigBee networks comprised of several nodes that carry the traffic of wearable electrocardiogram (ECG) sensors. The results indicate that star networks can relay 100% of the traffic generated by at least 12 ECG nodes. In tree topologies, the increase of the network traffic load reduces the performance but even these networks can reliably relay the traffic of a considerable number of ECG nodes.Fundação para a Ciência e a Tecnologia (FCT)Grupo AMI – Assistência Médica Integral (Casa de Saúde Guimarães, SA

    FREE-FORM TOOLS DESIGN AND FABRICATION FOR FLANK SUPER ABRASIVE MACHINING (FSAM) NON DEVELOPABLE SURFACES

    Get PDF
    Manufacturing improvements are becoming a real need in industry. In order to satisfy these industrial requirements, they should be targeted in two different directions: new manufacturing processes and surface optimization through algorithms. On the one hand, Super Abrasive Machining (SAM) is presented as a new manufacturing process combining benefits from milling and grinding technologies. On the other hand, there is a tendency to manufacture non developable surfaces by flank milling and to achieve final dimensional and roughness requirements, by calculating mathematically-optimized tool trajectories. This work presents a design and manufacturing of a free form tool to be used for the manufacturing of a complex surface through Flank SAM (FSAM). Based on the tool requirements, it will cover the following stages: tool geometry design, tool core manufacturing, and electroplating for final abrasive tool generation

    Thermal Bremsstrahlung photons probing the nuclear caloric curve

    Get PDF
    Hard-photon (Eγ>_{\gamma}> 30 MeV) emission from second-chance nucleon-nucleon Bremsstrahlung collisions in intermediate energy heavy-ion reactions is studied employing a realistic thermal model. Photon spectra and yields measured in several nucleus-nucleus reactions are consistent with an emission from hot nuclear systems with temperatures TT\approx 4 - 7 MeV. The corresponding caloric curve in the region of excitation energies ϵ\epsilon^\star\approx 3{\it A} - 8{\it A} MeV shows lower values of TT than those expected for a Fermi fluid.Comment: 13 pages, 3 figures. To appear in Physics Letters

    Genome-Wide Methylation Profiling in the Thalamus of Scrapie Sheep

    Get PDF
    Scrapie is a neurodegenerative disorder belonging to the group of transmissible spongiform encephalopathy (TSE). Scrapie occurs in sheep and goats, which are considered good natural animal models of these TSE. Changes in DNA methylation occur in the central nervous system (CNS) of patients suffering from prion-like neurodegenerative diseases, such as Alzheimer''s disease. Nevertheless, potential DNA methylation alterations have not yet been investigated in the CNS of any prion disease model or naturally infected cases, neither in humans nor in animals. Genome-wide DNA methylation patterns were studied in the thalamus obtained from sheep naturally infected with scrapie at a clinical stage (n = 4) and from controls (n = 4) by performing a whole-genome bisulfite sequencing (WGBS) analysis. Ewes carried the scrapie-susceptible ARQ/ARQ PRNP genotype and were sacrificed at a similar age (4–6 years). Although the average genomic methylation levels were similar between the control and the scrapie animals, we identified 8, 907 significant differentially methylated regions (DMRs) and 39 promoters (DMPs). Gene Ontology analysis revealed that hypomethylated DMRs were enriched in genes involved in transmembrane transport and cell adhesion, whereas hypermethylated DMRs were related to intracellular signal transduction genes. Moreover, genes highly expressed in specific types of CNS cells and those previously described to be differentially expressed in scrapie brains contained DMRs. Finally, a quantitative PCR (qPCR) validation indicated differences in the expression of five genes (PCDH19, SNCG, WDR45B, PEX1, and CABIN1) that matched the methylation changes observed in the genomic study. Altogether, these results suggest a potential regulatory role of DNA methylation in prion neuropathology. Copyright © 2022 Hernaiz, Sanz, Sentre, Ranera, Lopez-Pérez, Zaragoza, Badiola, Filali, Bolea, Toivonen and Martín-Burriel

    A Drastic Shift in Lipid Adducts in Colon Cancer Detected by MALDI-IMS Exposes Alterations in Specific K+ Channels

    Get PDF
    Even though colorectal cancer (CRC) is one of the most preventable cancers, it is one of the deadliest, and recent data show that the incidence in people <50 years has unexpectedly increased. While new techniques for CRC molecular classification are emerging, no molecular feature is as yet firmly associated with prognosis. Imaging mass spectrometry (IMS) lipidomic analyses have demonstrated the specificity of the lipid fingerprint in differentiating pathological from healthy tissues. During IMS lipidomic analysis, the formation of ionic adducts is common. Of particular interest is the [Na+]/[K+] adduct ratio, which already functions as a biomarker for homeostatic alterations. Herein, we show a drastic shift of the [Na+]/[K+] adduct ratio in adenomatous colon mucosa compared to healthy mucosa, suggesting a robust increase in K+ levels. Interrogating public databases, a strong association was found between poor diagnosis and voltage-gated potassium channel subunit beta-2 (KCNAB2) overexpression. We found this overexpression in three CRC molecular subtypes defined by the CRC Subtyping Consortium, making KCNAB2 an interesting pharmacological target. Consistently, its pharmacological inhibition resulted in a dramatic halt in commercial CRC cell proliferation. Identification of potential pharmacologic targets using lipid adduct information emphasizes the great potential of IMS lipidomic techniques in the clinical field.This study was supported in part by the Institute of Health Carlos III (CP12/03338 and PI16/02200), Basque Government (IT1162-19), and the EC (European Regional Development Fund, ERDF, CP12/03338). A.M.B. and J.B-E. hold predoctoral fellowships of the Govern Balear (Direcció General d’Innovació i Recerca, FPI/2160/2018 and FPI/1787/2015, respectively), co-funded by the ESF (European Social Fund). K.P.-R. contract was supported by the Govern Balear (Servei d’Ocupació de les IIles Balears and Garantia Juvenil, JQ-SP 18/17), co-funded by the ESF. G.B.-C. and D.H.L.’s contracts were supported by the Institute of Health Carlos III, co-funded by ERDF (Miguel Servet II program, CPII17/00005 and PI16/02200, respectively). We are grateful to SGiker Lipidomic Service (UPV/EHU, MICINN, GV/EG, ESF) for the expert advice and technical and human support in MALDI-IMS analysis. The publication fee in this Open Access journal is fully supported by the Liberi Call of the IdISBa

    Structural and compositional properties of brown dwarf disks: the case of 2MASS J04442713+2512164

    Get PDF
    In order to improve our understanding of substellar formation, we have performed a compositional and structural study of a brown dwarf disk. We present the result of photometric, spectroscopic and imaging observations of 2MASS J04442713+2512164, a young brown dwarf (M7.25) member of the Taurus association. Our dataset, combined with results from the literature, provides a complete coverage of the spectral energy distribution from the optical to the millimeter including the first photometric measurement of a brown dwarf disk at 3.7mm, and allows us to perform a detailed analysis of the disk properties. The target was known to have a disk. High resolution optical spectroscopy shows that it is intensely accreting, and powers a jet and an outflow. The disk structure is similar to that observed for more massive TTauri stars. Spectral decomposition models of Spitzer/IRS spectra suggest that the mid-infrared emission from the optically thin disk layers is dominated by grains with intermediate sizes (1.5micron). Crystalline silicates are significantly more abondant in the outer part and/or deeper layers of the disk, implying very efficient mixing and/or additional annealing processes. Sub-millimeter and millimeter data indicate that most of the disk mass is in large grains (>1mm)Comment: 17 pages, 10 figures, 7 tables, accepted for A&

    Dynamic and wear study of an extremely bidisperse magnetorheological fluid

    Get PDF
    Acceso a la versión publicada en Smart Mater. Struct. 24(12) 127001 (http://iopscience.iop.org/0964-1726/24/12/127001)"This is an author-created, un-copyedited version of an article accepted for publication/published in Smart Materials and Structures. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/0964-1726/24/12/127001."In this work the friction and wear properties of five magnetorheologicalfluids (MRFs)with varying compositions are investigated. Considering that many of the proposed applications for these fluids involve lubricated contact between mobile metal –metal or polymer– metal parts, the relationship between MR response and wear behavior appears to be of fundamental importance. One of the fluids(MR#1)contains only the iron microparticles and base oil; the second and third ones(MR#2 and MR#3) contain an anti-wear additive as well. The fourth one(MR#4)is a well known commercial MRF. Finally, MR#5 is stabilized by dispersing the iron particles in a magnetite ferrofluid. The MR response of the latter fluid is better(higher yield stress and post-yield viscosity)than that of the others. More importantly, it remains(and even improves)after the wear test: the pressure applied in the four-ball apparatus produces a compaction of the magnetite layer around the iron microparticles. Additionally, the friction coefficient is larger, which seems paradoxical in principle, but can be explained by considering the stability of MR#5 in comparison to the other four MRs, which appear to undergo partial phase separation during the test. In fact, electron and optical microscope observations confirm a milder wear effect of MR#5, with almost complete absence of scars from the steel test spheres and homogeneous and shallow grooves on them. Comparatively, MR#2, MR#3 and, particularly, MR#1 produce a much more significant wear.MINECO Ramón y Cajal Programme (RYC-2014-16901)MINECO FIS 2013-07666-C3-1-RCEI Biotic BS27.2015Junta de Andalucía, PE2012-FQM-069

    Vault changes after cyclopentolate instillation in eyes with posterior chamber phakic intraocular lens

    Get PDF
    Posterior chamber phakic intraocular lens (pIOL) implantation is a common option for correcting moderate-to-high ocular refractive defects. Because this pIOL is implanted on ciliary sulcus, the distance between the back surface of the pIOL and the anterior surface of the crystalline lens, that it is known as vault, should be measured in different conditions to ensure the technique's safety. Cyclopentolate is a drug that dilates the pupil and relaxes accommodation (cycloplegia). It is often used for different ocular examinations and for other medical purposes. However, there is no evidence of the effect of this drug on vault. This study quantified central vault changes associated with cyclopentolate instillation. We measured the vault under normal conditions (pre-cycloplegic instillation) and after instilling cyclopentolate on 39 eyes of 39 patients with implanted pIOL. Our results suggest that cyclopentolate instillation may induce changes to vault in eyes with implanted pIOL. These changes seem safe and are mainly associated with vault under normal conditions, but also with anterior chamber depth, pupillary diameter and pIOL size.- European Fund for Regional Development (FEDER) through the COMPETE Program and the Portuguese Foundation for Science and Technology (FCT) provided financial support in the framework of projects PTDC/SAU-BEB/098391/2008, PTDC/SAU-BEB/098392/2008 and the Strategic Project PEST-C/FIS/UI607/2011

    Search for coherent charged pion production in neutrino-carbon interactions

    Get PDF
    We report the result from a search for charged-current coherent pion production induced by muon neutrinos with a mean energy of 1.3 GeV. The data are collected with a fully active scintillator detector in the K2K long-baseline neutrino oscillation experiment. No evidence for coherent pion production is observed and an upper limit of 0.60×1020.60 \times 10^{-2} is set on the cross section ratio of coherent pion production to the total charged-current interaction at 90% confidence level. This is the first experimental limit for coherent charged pion production in the energy region of a few GeV.Comment: 5 pages, 4 figure

    The Circumgalactic Medium in Massive Halos

    Full text link
    This chapter presents a review of the current state of knowledge on the cool (T ~ 1e4 K) halo gas content around massive galaxies at z ~ 0.2-2. Over the last decade, significant progress has been made in characterizing the cool circumgalactic gas in massive halos of Mh ~ 1e12-1e14 Msun at intermediate redshifts using absorption spectroscopy. Systematic studies of halo gas around massive galaxies beyond the nearby universe are made possible by large spectroscopic samples of galaxies and quasars in public archives. In addition to accurate and precise constraints for the incidence of cool gas in massive halos, detailed characterizations of gas kinematics and chemical compositions around massive quiescent galaxies at z ~ 0.5 have also been obtained. Combining all available measurements shows that infalling clouds from external sources are likely the primary source of cool gas detected at d >~ 100 kpc from massive quiescent galaxies. The origin of the gas closer in is currently less certain, but SNe Ia driven winds appear to contribute significantly to cool gas found at d < 100 kpc. In contrast, cool gas observed at d <~ 200 kpc from luminous quasars appears to be intimately connected to quasar activities on parsec scales. The observed strong correlation between cool gas covering fraction in quasar host halos and quasar bolometric luminosity remains a puzzle. Combining absorption-line studies with spatially-resolved emission measurements of both gas and galaxies is the necessary next step to address remaining questions.Comment: 29 pages, 7 figures, invited review to appear in "Gas Accretion onto Galaxies", Astrophysics and Space Science Library, eds. A. Fox & R. Dave, to be published by Springe
    corecore