25 research outputs found

    The 13th Data Release of the Sloan Digital Sky Survey: First Spectroscopic Data from the SDSS-IV Survey Mapping Nearby Galaxies at Apache Point Observatory

    Get PDF
    The fourth generation of the Sloan Digital Sky Survey (SDSS-IV) began observations in July 2014. It pursues three core programs: APOGEE-2,MaNGA, and eBOSS. In addition, eBOSS contains two major subprograms: TDSS and SPIDERS. This paper describes the first data release from SDSS-IV, Data Release 13 (DR13), which contains new data, reanalysis of existing data sets and, like all SDSS data releases, is inclusive of previously released data. DR13 makes publicly available 1390 spatially resolved integral field unit observations of nearby galaxies from MaNGA,the first data released from this survey. It includes new observations from eBOSS, completing SEQUELS. In addition to targeting galaxies and quasars, SEQUELS also targeted variability-selected objects from TDSS and X-ray selected objects from SPIDERS. DR13 includes new reductions ofthe SDSS-III BOSS data, improving the spectrophotometric calibration and redshift classification. DR13 releases new reductions of the APOGEE-1data from SDSS-III, with abundances of elements not previously included and improved stellar parameters for dwarf stars and cooler stars. For the SDSS imaging data, DR13 provides new, more robust and precise photometric calibrations. Several value-added catalogs are being released in tandem with DR13, in particular target catalogs relevant for eBOSS, TDSS, and SPIDERS, and an updated red-clump catalog for APOGEE.This paper describes the location and format of the data now publicly available, as well as providing references to the important technical papers that describe the targeting, observing, and data reduction. The SDSS website, http://www.sdss.org, provides links to the data, tutorials and examples of data access, and extensive documentation of the reduction and analysis procedures. DR13 is the first of a scheduled set that will contain new data and analyses from the planned ~6-year operations of SDSS-IV.PostprintPeer reviewe

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    Stimulation crosstalk between cochlear and vestibular spaces during cochlear electrical stimulation

    No full text
    Abstract: ObjectivesPossible beneficial "crosstalk" during cochlear implant stimulation on otolith end organs has been hypothesized. The aim of this case-control study is to analyze the effect of electrical cochlear stimulation on the vestibule (otolith end-organ), when using a cochleo-vestibular implant, comparing vestibular stimulation (VI) and cochlear stimulation (CI).MethodsFour patients with bilateral vestibulopathy were included. A double electrode array research implant was implanted in all cases. Dynamic Gait Index (DGI), VOR gain measured by using vestibular head impulse test (vHIT), acoustic cervical myogenic responses (cVEMP) recordings, and electrical cVEMP were used in all cases. Trans-impedance Matrix (TIM) analysis was used to evaluate the current flow from the cochlea to the vestibule.ResultsWhile patients did not have any clinical vestibular improvement with the CI stimulation alone, gait metrics of the patients revealed improvement when the vestibular electrode was stimulated. The average improvement in the DGI was 38% when the vestibular implant was activated, returning to the normal range in all cases. Our findings suggest that any current flow from the cochlear space to the otolith organs was insufficient for effective cross-stimulation. The functional results correlated with the data obtained in TIM analysis, confirming that there is no current flow from the cochlea to the vestibule.ConclusionThe only way to produce effective electrical otolith end-organ stimulation, demonstrated with this research implant, is by direct electrical stimulation of the otolith end organs. No effective cross-stimulation was found from cochlear electrode stimulation.Level of Evidence4 Laryngoscope, 2023 We analyze in this research the possible beneficial "crosstalk" during cochlear implant stimulation on otolith end organs has been hypothesized. The aim of this study is to analyze the effect of electrical cochlear stimulation on the vestibule (otolith end organ), when using a cochleo-vestibular implant.imag

    A Comparative Study on Speech in Noise Understanding with a Direct Acoustic Cochlear Implant in Subjects with Severe to Profound Mixed Hearing Loss

    No full text
    The aim of this study was to investigate the efficacy of a direct acoustic cochlear implant (DACI) for speech understanding in noise in patients suffering from severe to profound mixed hearing loss (MHL) due to various etiologies compared to the preoperative best-aided condition. The study was performed at five tertiary referral centers in Europe (Belgium, Germany, Poland and Spain). Nineteen adult subjects with severe to profound MHL due to (advanced) otosclerosis, ear canal fibrosis, chronic otitis media, tympanosclerosis or previous cholesteatoma were implanted with a DACI (Codacs™ Investigational Device) combined with a conventional stapes prosthesis. Unaided and aided speech reception scores in quiet and in noise, preoperative and postoperative air and bone conduction thresholds and aided and unaided sound field thresholds were measured prospectively during the study. Subjective benefit analysis was determined through the Abbreviated Profile of Hearing Aid Benefit questionnaire. Quality of life was measured by the Health Utilities Index. All subjects were fitted preoperatively with hearing aids and/or a bone conduction implant on a headband before DACI implantation. This allows direct comparison between different hearing rehabilitation solutions. The mean speech reception threshold in noise improved significantly by 7.9 dB signal-to-noise ratio (SNR) after activation of the DACI compared to the preoperative best-aided condition. For all 19 subjects, a mean postoperative aided speech reception threshold of 2.6 dB SNR (standard deviation: 8.3 dB) was measured. On average, no significant shift in the bone conduction thresholds was noted 4-5 months after implantation. A mean sound field threshold improvement of 46 and 16 dB was measured compared to the preoperative unaided and best-aided condition, respectively. Speech perception tests in quiet showed a mean improvement of the word recognition scores by 65 and 48% at 65 dB SPL compared to the preoperative unaided and best-aided condition, respectively. In summary, DACI provides an effective improvement of the speech perception in noise compared to the best-aided condition in subjects suffering from severe to profound MHL.status: publishe

    The Pierre Auger Observatory: Contributions to the 33rd International Cosmic Ray Conference (ICRC 2013)

    No full text
    Contributions of the Pierre Auger Collaboration to the 33rd International Cosmic Ray Conference, Rio de Janeiro, Brazil, July 201

    Interpretation of the depths of maximum of extensive air showers measured by the Pierre Auger Observatory

    No full text
    corecore