146 research outputs found

    An integrated space physics instrument (ISPI) for Solar Probe

    Full text link
    Instruments for the Solar Probe mission must be designed not only to address the unique scientific measurement requirements, but must be compatible with the modest resource dollars as well as tight constraints on mass and power. Another unique aspect of the Solar Probe mission is its constraint on telemetry and the fact that the prime science is conducted in a single flyby. The instrument system must be optimized to take advantage of the telemetry and observing time available. JPL, together with industry and university partners, is designing an Integrated Space Physics Instrument (ISPI) which will measure magnetic fields, plasma waves, thermal plasma, energetic particles, dust, and perform EUV/visible and coronal imaging for the Solar Probe mission. ISPI uses a new architecture and incorporates technology which not only eliminates unnecessary duplication of function, but allows sensors to share data and optimize science. The current ISPI design goal (for a flight package) is a 5 kilogram/10 watt payload. © 1997 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/87393/2/131_1.pd

    Rosina - Rosetta Orbiter Spectrometer for Ion and Neutral Analysis

    Get PDF
    The Rosetta Orbiter Spectrometer for Ion and Neutral Analysis (ROSINA) will answer important questions posed by the mission's main objectives. After Giotto, this will be the first time the volatile part of a comet will be analyzed in situ. This is a very important investigation, as comets, in contrast to meteorites, have maintained most of the volatiles of the solar nebula. To accomplish the very demanding objectives through all the different phases of the comet's activity, ROSINA has unprecedented capabilities including very wide mass range (1 to >300 amu), very high mass resolution (m/Δ m > 3000, i.e. the ability to resolve CO from N2 and 13C from 12CH), very wide dynamic range and high sensitivity, as well as the ability to determine cometary gas velocities, and temperature. ROSINA consists of two mass spectrometers for neutrals and primary ions with complementary capabilities and a pressure sensor. To ensure that absolute gas densities can be determined, each mass spectrometer carries a reservoir of a calibrated gas mixture allowing in-flight calibration. Furthermore, identical flight-spares of all three sensors will serve for detailed analysis of all relevant parameters, in particular the sensitivities for complex organic molecules and their fragmentation patterns in our electron bombardment ion source

    Validation of a Persian version of the OIDP index

    Get PDF
    BACKGROUND: Measuring the impacts of oral conditions on quality of life is an important part of oral health needs assessment. For this purpose a variety of oral health-related quality of life instruments have been developed. To use a scale in a new context or with a different groups of people, it is necessary to re-establish its psychometric properties. The objectives of this study are to develop and test the reliability and validity of the Persian version of Oral Impacts on Daily Performances (OIDP) index. METHODS: The Persian version of OIDP index was developed through a linguistic translation exercise. The psychometric properties of the Persian version of OIDP were evaluated in terms of face, content, construct and criterion validity in addition to internal and test-retest reliability. A convenience sample of 285 working adults aged 20–50 living in Mashad was recruited (91% response rate) to evaluate the Persian version. RESULTS: The Persian version of OIDP had excellent validity and reliability charactersitics. Weighted Kappa was 0.91. Cronbachs alpha coefficient was 0.79. The index showed significant associations with self-rated oral and general health status, as well as perceived dental treatment needs, satisfaction with mouth and prevalence of pain in mouth (P < 0.001). 64.9% of subjects had an oral impact on their daily performances. The most prevalent performance affected was eating, followed by major work or role and sleeping. CONCLUSION: The Persian version of OIDP index is a valid and reliable measure for use in 20 to 50 year old working Iranians

    Neural networks and dynamical systems

    Get PDF
    AbstractModels for the identification and control of nonlinear dynamical systems using neural networks were introduced by Narendra and Parthasarathy in 1990, and methods for the adjustment of model parameters were also suggested. Simulation results of simple nonlinear systems were presented to demonstrate the feasibility of the schemes proposed. The concepts introduced at that time are investigated in this paper in greater detail. In particular, a number of questions that arise when the methods are applied to more complex systems are addressed. These include nonlinear systems of higher order as well as multivariable systems. The effect of using simpler models for both identification and control are discussed, and a new controller structure containing a linear part in addition to a multilayer neural network is introduced

    Effects of Transport Inhibitors on the Cellular Uptake of Carboxylated Polystyrene Nanoparticles in Different Cell Lines

    Get PDF
    Nanotechnology is expected to play a vital role in the rapidly developing field of nanomedicine, creating innovative solutions and therapies for currently untreatable diseases, and providing new tools for various biomedical applications, such as drug delivery and gene therapy. In order to optimize the efficacy of nanoparticle (NP) delivery to cells, it is necessary to understand the mechanisms by which NPs are internalized by cells, as this will likely determine their ultimate sub-cellular fate and localisation. Here we have used pharmacological inhibitors of some of the major endocytic pathways to investigate nanoparticle uptake mechanisms in a range of representative human cell lines, including HeLa (cervical cancer), A549 (lung carcinoma) and 1321N1 (brain astrocytoma). Chlorpromazine and genistein were used to inhibit clathrin and caveolin mediated endocytosis, respectively. Cytochalasin A and nocodazole were used to inhibit, respectively, the polymerisation of actin and microtubule cytoskeleton. Uptake experiments were performed systematically across the different cell lines, using carboxylated polystyrene NPs of 40 nm and 200 nm diameters, as model NPs of sizes comparable to typical endocytic cargoes. The results clearly indicated that, in all cases and cell types, NPs entered cells via active energy dependent processes. NP uptake in HeLa and 1321N1 cells was strongly affected by actin depolymerisation, while A549 cells showed a stronger inhibition of NP uptake (in comparison to the other cell types) after microtubule disruption and treatment with genistein. A strong reduction of NP uptake was observed after chlorpromazine treatment only in the case of 1321N1 cells. These outcomes suggested that the same NP might exploit different uptake mechanisms to enter different cell types

    OSIRIS – The scientific camera system onboard Rosetta

    Get PDF
    The Optical, Spectroscopic, and Infrared Remote Imaging System OSIRIS is the scientific camera system onboard the Rosetta spacecraft (Figure 1). The advanced high performance imaging system will be pivotal for the success of the Rosetta mission. OSIRIS will detect 67P/Churyumov-Gerasimenko from a distance of more than 106 km, characterise the comet shape and volume, its rotational state and find a suitable landing spot for Philae, the Rosetta lander. OSIRIS will observe the nucleus, its activity and surroundings down to a scale of ~2 cm px−1. The observations will begin well before the onset of cometary activity and will extend over months until the comet reaches perihelion. During the rendezvous episode of the Rosetta mission, OSIRIS will provide key information about the nature of cometary nuclei and reveal the physics of cometary activity that leads to the gas and dust coma. OSIRIS comprises a high resolution Narrow Angle Camera (NAC) unit and a Wide Angle Camera (WAC) unit accompanied by three electronics boxes. The NAC is designed to obtain high resolution images of the surface of comet 7P/Churyumov-Gerasimenko through 12 discrete filters over the wavelength range 250–1000 nm at an angular resolution of 18.6 μrad px−1. The WAC is optimised to provide images of the near-nucleus environment in 14 discrete filters at an angular resolution of 101 μrad px−1. The two units use identical shutter, filter wheel, front door, and detector systems. They are operated by a common Data Processing Unit. The OSIRIS instrument has a total mass of 35 kg and is provided by institutes from six European countrie

    The genomic landscape of balanced cytogenetic abnormalities associated with human congenital anomalies

    Get PDF
    Despite the clinical significance of balanced chromosomal abnormalities (BCAs), their characterization has largely been restricted to cytogenetic resolution. We explored the landscape of BCAs at nucleotide resolution in 273 subjects with a spectrum of congenital anomalies. Whole-genome sequencing revised 93% of karyotypes and demonstrated complexity that was cryptic to karyotyping in 21% of BCAs, highlighting the limitations of conventional cytogenetic approaches. At least 33.9% of BCAs resulted in gene disruption that likely contributed to the developmental phenotype, 5.2% were associated with pathogenic genomic imbalances, and 7.3% disrupted topologically associated domains (TADs) encompassing known syndromic loci. Remarkably, BCA breakpoints in eight subjects altered a single TAD encompassing MEF2C, a known driver of 5q14.3 microdeletion syndrome, resulting in decreased MEF2C expression. We propose that sequence-level resolution dramatically improves prediction of clinical outcomes for balanced rearrangements and provides insight into new pathogenic mechanisms, such as altered regulation due to changes in chromosome topology
    corecore