339 research outputs found

    Mayday SeaSight: Combined Analysis of Deep Sequencing and Microarray Data

    Get PDF
    Recently emerged deep sequencing technologies offer new high-throughput methods to quantify gene expression, epigenetic modifications and DNA-protein binding. From a computational point of view, the data is very different from that produced by the already established microarray technology, providing a new perspective on the samples under study and complementing microarray gene expression data. Software offering the integrated analysis of data from different technologies is of growing importance as new data emerge in systems biology studies. Mayday is an extensible platform for visual data exploration and interactive analysis and provides many methods for dissecting complex transcriptome datasets. We present Mayday SeaSight, an extension that allows to integrate data from different platforms such as deep sequencing and microarrays. It offers methods for computing expression values from mapped reads and raw microarray data, background correction and normalization and linking microarray probes to genomic coordinates. It is now possible to use Mayday's wealth of methods to analyze sequencing data and to combine data from different technologies in one analysis

    Convalescent Pulmonary Dysfunction Following Hantavirus Pulmonary Syndrome in Panama and the United States

    Get PDF
    The objective of this study was to document persistent pulmonary symptoms and pulmonary function abnormalities in adults surviving hantavirus pulmonary syndrome (HPS). Acute infection by most hantaviruses result in mortality rates of 25–35%, while in Panama the mortality rate of 10% is contrasted by an unusually high incidence. In all types of HPS, the viral prodrome, cardiopulmonary phase due to massive pulmonary capillary leak syndrome, and spontaneous diuresis are followed by a convalescent phase with exertional dyspnea for 3–4 weeks, but the frequency of persistent symptoms is not known. In this observational study of a convenience sample, 14 survivors of HPS caused by Choclo virus infection in Panama and 9 survivors of HPS caused by Sin Nombre virus infection in New Mexico completed a questionnaire and pulmonary function tests up to 8 years after infection. In both groups, exertional dyspnea persisted for 1–2 years after acute infection in 43% (Panama) and 77% (New Mexico) of survivors surveyed. Reduction in midexpiratory flows (FEF25–75%), increased residual volume (RV), and reduced diffusion capacity (DLCO/VA) also were common in both populations; but the severity of reduced expiratory flow did not correlate with exertional dyspnea. Symptoms referable to previous hantavirus infection had resolved within 3 years of acute infection in most but not all patients in the Panama group. Temporary exertional dyspnea and reduced expiratory flow are common in early convalescence after HPS but resolves in almost all patients

    Biomechanical evaluation of fixation of comminuted olecranon fractures: one-third tubular versus locking compression plating

    Get PDF
    New concepts in plate fixation have led to an evolution in plate design for olecranon fractures. The purpose of this study was to compare the stiffness and strength of locking compression plate (LCP) fixation to one-third tubular plate fixation in a cadaveric comminuted olecranon fracture model with a standardised osteotomy. Five matched pairs of cadaveric elbows were randomly assigned for fixation by either a contoured LCP combined with an intramedullary screw and unicortical locking screws or a one-third tubular plate combined with bicortical screws. Construct stiffness was measured by subjecting the specimens to cyclic loading while measuring gapping at the osteotomy site. Construct strength was measured by subjecting specimens to ramp load until failure. There was no significant difference in fixation stiffness and strength between the two fixation methods. All failures consisted of failure of the bone and not of the hardware. Contoured LCP and intramedullary screw fixation can be used as an alternative treatment method for comminuted olecranon fractures as its stiffness and strength were not significantly different from a conventional plating techniqu

    The distal fascicle of the anterior inferior tibiofibular ligament as a cause of tibiotalar impingement syndrome: a current concepts review

    Get PDF
    Impingement syndromes of the ankle involve either osseous or soft tissue impingement and can be anterior, anterolateral, or posterior. Ankle impingement syndromes are painful conditions caused by the friction of joint tissues, which are both the cause and the effect of altered joint biomechanics. The distal fascicle of the anterior inferior tibiofibular ligament (AITFL) is possible cause of anterior impingement. The objective of this article was to review the literature concerning the anatomy, pathogenesis, symptoms and treatment of the AITFL impingement and finally to formulate treatment recommendations. The AITFL starts from the distal tibia, 5 mm in average above the articular surface, and descends obliquely between the adjacent margins of the tibia and fibula, anterior to the syndesmosis to the anterior aspect of the lateral malleolus. The incidence of the accessory fascicle differs very widely in the several studies. The presence of the distal fascicle of the AITFL and also the contact with the anterolateral talus is probably a normal finding. It may become pathological, due to anatomical variations and/or anterolateral instability of the ankle resulting from an anterior talofibular ligament injury. When observed during an ankle arthroscopy, the surgeon should look for the criteria described to decide whether it is pathological and considering resection of the distal fascicle. The presence of the AITFL and the contact with the talus is a normal finding. An impingement of the AITFL can result from an anatomical variant or anteroposterior instability of the ankle. The diagnosis of ligamentous impingement in the anterior aspect of the ankle should be considered in patients who have chronic ankle pain in the anterolateral aspect of the ankle after an inversion injury and have a stable ankle, normal plain radiographs, and isolated point tenderness on the anterolateral aspect of the talar dome and in the anteroinferior tibiofibular ligament. The impingement syndrome can be treated arthroscopically

    Is tension band wiring technique the "gold standard" for the treatment of olecranon fractures? A long term functional outcome study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Tension band wiring (TBW) remains the most common operative technique for the internal fixation of olecranon fractures despite the potential occurrence of subjective complaints due to subcutaneous position of the hardware. Aim of this long term retrospective study was to evaluate the elbow function and the patient-rated outcome after TBW fixation of olecranon fractures.</p> <p>Methods</p> <p>We reviewed 62 patients (33 men and 29 women) with an average age of 48.6 years (range, 18–85 years) who underwent TBW osteosynthesis for isolated olecranon fractures. All patients were assessed both clinically with measurement of flexion-extension and pronation-supination arcs and radiologically with elbow X-Rays. Functional outcome was estimated using the Mayo Elbow Performance Score (MEPS), Visual Analogue Scale (VAS) subjective pain score and VAS patient satisfaction score. Follow up: 6–13 years (average 8.2 years).</p> <p>Results</p> <p>There was a higher prevalence of fractures among men until the 5th decade of life and among women in elderly (p = 0.032). Slip or simple fall onto the arm was the main mechanism of injury for 38 fractures (61.3%) while high energy trauma, such as fall from a height (> 2 m) or road accident, was reported in 24 fractures (38.7%). Hardware removal performed in 51 patients (82.3%) but 34 of them (66.6% of removals) were still complaining for mild pain during daily activities. The incidence of pin migration and loosening was not statistically decreased when penetration of the anterior ulnar cortex was accomplished (p = 0.304). Supination was more often affected than pronation (p = 0.027). According to MEPS, 53 patients (85.5%) had a good to excellent result, 6 (9.7%) fair and 3 (4.8%) poor result. The average satisfaction rating was 9.3 out of 10 (range, 6–10) with 31 patients (50%) to remain completely satisfied from the final result. Degenerative changes recorded in 30 elbows (48.4%). However, no correlation could be found between radiographic findings and MEPS (p = 0.073).</p> <p>Conclusion</p> <p>Tension band wiring fixation remains the "gold standard" for the treatment of displaced and minimally comminuted olecranon fractures. In long term, low levels of pain may be evident regardless of whether the metalware is removed and degenerative changes have been developed.</p

    Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV

    Get PDF
    The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of √s = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pT≄20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60≀pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2≀{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration

    Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector

    Get PDF
    The inclusive and dijet production cross-sections have been measured for jets containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The measurements use data corresponding to an integrated luminosity of 34 pb^-1. The b-jets are identified using either a lifetime-based method, where secondary decay vertices of b-hadrons in jets are reconstructed using information from the tracking detectors, or a muon-based method where the presence of a muon is used to identify semileptonic decays of b-hadrons inside jets. The inclusive b-jet cross-section is measured as a function of transverse momentum in the range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet cross-section is measured as a function of the dijet invariant mass in the range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets and the angular variable chi in two dijet mass regions. The results are compared with next-to-leading-order QCD predictions. Good agreement is observed between the measured cross-sections and the predictions obtained using POWHEG + Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet cross-section. However, it does not reproduce the measured inclusive cross-section well, particularly for central b-jets with large transverse momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final version published in European Physical Journal

    Glycine insertion makes yellow fluorescent protein sensitive to hydrostatic pressure

    Get PDF
    Fluorescent protein-based indicators for intracellular environment conditions such as pH and ion concentrations are commonly used to study the status and dynamics of living cells. Despite being an important factor in many biological processes, the development of an indicator for the physicochemical state of water, such as pressure, viscosity and temperature, however, has been neglected. We here found a novel mutation that dramatically enhances the pressure dependency of the yellow fluorescent protein (YFP) by inserting several glycines into it. The crystal structure of the mutant showed that the tyrosine near the chromophore flipped toward the outside of the ÎČ-can structure, resulting in the entry of a few water molecules near the chromophore. In response to changes in hydrostatic pressure, a spectrum shift and an intensity change of the fluorescence were observed. By measuring the fluorescence of the YFP mutant, we succeeded in measuring the intracellular pressure change in living cell. This study shows a new strategy of design to engineer fluorescent protein indicators to sense hydrostatic pressure

    Search for the neutral Higgs bosons of the minimal supersymmetric standard model in pp collisions at root s=7 TeV with the ATLAS detector

    Get PDF
    A search for neutral Higgs bosons of the Minimal Supersymmetric Standard Model (MSSM) is reported. The analysis is based on a sample of proton-proton collisions at a centre-of-mass energy of 7TeV recorded with the ATLAS detector at the Large Hadron Collider. The data were recorded in 2011 and correspond to an integrated luminosity of 4.7 fb-1 to 4.8 fb-1. Higgs boson decays into oppositely-charged muon or τ lepton pairs are considered for final states requiring either the presence or absence of b-jets. No statistically significant excess over the expected background is observed and exclusion limits at the 95% confidence level are derived. The exclusion limits are for the production cross-section of a generic neutral Higgs boson, φ, as a function of the Higgs boson mass and for h/A/H production in the MSSM as a function of the parameters mA and tan ÎČ in the mhmax scenario for mA in the range of 90GeV to 500 GeV. Copyright CERN

    Search for R-parity-violating supersymmetry in events with four or more leptons in sqrt(s) =7 TeV pp collisions with the ATLAS detector

    Get PDF
    A search for new phenomena in final states with four or more leptons (electrons or muons) is presented. The analysis is based on 4.7 fb−1 of s=7  TeV \sqrt{s}=7\;\mathrm{TeV} proton-proton collisions delivered by the Large Hadron Collider and recorded with the ATLAS detector. Observations are consistent with Standard Model expectations in two signal regions: one that requires moderate values of missing transverse momentum and another that requires large effective mass. The results are interpreted in a simplified model of R-parity-violating supersymmetry in which a 95% CL exclusion region is set for charged wino masses up to 540 GeV. In an R-parity-violating MSUGRA/CMSSM model, values of m 1/2 up to 820 GeV are excluded for 10 < tan ÎČ < 40
    • 

    corecore