658 research outputs found

    Low specificity of determine HIV1/2 RDT using whole blood in south west Tanzania

    Get PDF
    Objective: To evaluate the diagnostic performance of two rapid detection tests (RDTs) for HIV 1/2 in plasma and in whole blood samples. Methods: More than 15,000 study subjects above the age of two years participated in two rounds of a cohort study to determine the prevalence of HIV. HIV testing was performed using the Determine HIV 1/2 test (Abbott) in the first (2006/2007) and the HIV 1/2 STAT-PAK Dipstick Assay (Chembio) in the second round (2007/2008) of the survey. Positive results were classified into faint and strong bands depending on the visual appearance of the test strip and confirmed by ELISA and Western blot. Results: The sensitivity and specificity of the Determine RDT were 100% (95% confidence interval = 86.8 to 100%) and 96.8% (95.9 to 97.6%) in whole blood and 100% (99.7 to 100%) and 97.9% (97.6 to 98.1%) in plasma respectively. Specificity was highly dependent on the tested sample type: when using whole blood, 67.1% of positive results were false positive, as opposed to 17.4% in plasma. Test strips with only faint positive bands were more often false positive than strips showing strong bands and were more common in whole blood than in plasma. Evaluation of the STAT-PAK RDT in plasma during the second year resulted in a sensitivity of 99.7% (99.1 to 99.9%) and a specificity of 99.3% (99.1 to 99.4%) with 6.9% of the positive results being false. Conclusions: Our study shows that the Determine HIV 1/2 strip test with its high sensitivity is an excellent tool to screen for HIV infection, but that – at least in our setting – it can not be recommended as a confirmatory test in VCT campaigns where whole blood is used

    Use of alcoholic beverages in VA medical centers

    Get PDF
    BACKGROUND: Benzodiazepines are the first-line choice for the treatment of alcohol withdrawal syndrome. However, several hospitals continue to provide alcoholic beverages through their formulary for the treatment of alcohol withdrawal. While there are data on the prevalence of this practice in academic medical centers, there are no data on the availability of alcoholic beverages at the formularies of the hospitals operated by the department of Veteran's Affairs. METHODS: In this study, we surveyed the Pharmacy managers at 112 Veterans' Affairs Medical Centers (VAMCs) to ascertain the availability of alcohol on the VAMC formularies, and presence or lack of a policy on the use of alcoholic beverages in their VA Medical Center. RESULTS: Of the pharmacy directors contacted, 81 responded. 8 did not allow their use, while 20 allowed their use. There was a lack of a consistent policy across the VA medical centers on availability and use of alcoholic beverages for the treatment of alcohol withdrawal syndrome. CONCLUSION: There is lack of uniform policy on the availability of alcoholic beverages across the VAMCs, which may create potential problems with difference in the standards of care

    Positive and negative well-being and objectively measured sedentary behaviour in older adults: evidence from three cohorts

    Get PDF
    Background: Sedentary behaviour is related to poorer health independently of time spent in moderate to vigorous physical activity. The aim of this study was to investigate whether wellbeing or symptoms of anxiety or depression predict sedentary behaviour in older adults. Method: Participants were drawn from the Lothian Birth Cohort 1936 (LBC1936) (n = 271), and the West of Scotland Twenty-07 1950s (n = 309) and 1930s (n = 118) cohorts. Sedentary outcomes, sedentary time, and number of sit-to-stand transitions, were measured with a three-dimensional accelerometer (activPAL activity monitor) worn for 7 days. In the Twenty-07 cohorts, symptoms of anxiety and depression were assessed in 2008 and sedentary outcomes were assessed ~ 8 years later in 2015 and 2016. In the LBC1936 cohort, wellbeing and symptoms of anxiety and depression were assessed concurrently with sedentary behaviour in 2015 and 2016. We tested for an association between wellbeing, anxiety or depression and the sedentary outcomes using multivariate regression analysis. Results: We observed no association between wellbeing or symptoms of anxiety and the sedentary outcomes. Symptoms of depression were positively associated with sedentary time in the LBC1936 and Twenty-07 1950s cohort, and negatively associated with number of sit-to-stand transitions in the LBC1936. Meta-analytic estimates of the association between depressive symptoms and sedentary time or number of sit-to-stand transitions, adjusted for age, sex, BMI, long-standing illness, and education, were β = 0.11 (95% CI = 0.03, 0.18) and β = − 0.11 (95% CI = − 0.19, −0.03) respectively. Conclusion: Our findings indicate that depressive symptoms are positively associated with sedentary behavior. Future studies should investigate the causal direction of this association

    Comparison of eye tracking, electrooculography and an auditory brain-computer interface for binary communication: a case study with a participant in the locked-in state

    Get PDF
    Background In this study, we evaluated electrooculography (EOG), an eye tracker and an auditory brain-computer interface (BCI) as access methods to augmentative and alternative communication (AAC). The participant of the study has been in the locked-in state (LIS) for 6 years due to amyotrophic lateral sclerosis. He was able to communicate with slow residual eye movements, but had no means of partner independent communication. We discuss the usability of all tested access methods and the prospects of using BCIs as an assistive technology. Methods Within four days, we tested whether EOG, eye tracking and a BCI would allow the participant in LIS to make simple selections. We optimized the parameters in an iterative procedure for all systems. Results The participant was able to gain control over all three systems. Nonetheless, due to the level of proficiency previously achieved with his low-tech AAC method, he did not consider using any of the tested systems as an additional communication channel. However, he would consider using the BCI once control over his eye muscles would no longer be possible. He rated the ease of use of the BCI as the highest among the tested systems, because no precise eye movements were required; but also as the most tiring, due to the high level of attention needed to operate the BCI. Conclusions In this case study, the partner based communication was possible due to the good care provided and the proficiency achieved by the interlocutors. To ease the transition from a low-tech AAC method to a BCI once control over all muscles is lost, it must be simple to operate. For persons, who rely on AAC and are affected by a progressive neuromuscular disease, we argue that a complementary approach, combining BCIs and standard assistive technology, can prove valuable to achieve partner independent communication and ease the transition to a purely BCI based approach. Finally, we provide further evidence for the importance of a user-centered approach in the design of new assistive devices

    Dietary calcium and vitamin D intakes in childhood and throughout adulthood and mammographic density in a British birth cohort

    Get PDF
    We examined the role of dietary calcium and vitamin D intakes in childhood and throughout adulthood in relation to mammographic density using data from a nationally representative cohort of 1161 women followed up since their birth in 1946. Dietary intakes at the age of 4 years were determined by 24-h recalls and at the ages of 36, 43 and 53 years by 5-day food records. After adjusting for known risk factors and confounders, no evidence of a relationship between dietary calcium or vitamin D intakes and mammographic density approximately at the age of 50 years was found, except for a cross-sectional relationship between dietary calcium intake at the age of 53 years and breast density in women who were post-menopausal at the time of mammography, with those in the top fifth of the distribution of calcium intake having a 0.53 s.d. lower percent breast density than those in the lowest fifth (P-value <0.01 for linear trend)

    Measurement of Warfarin in the Oral Fluid of Patients Undergoing Anticoagulant Oral Therapy

    Get PDF
    BACKGROUND: Patients on warfarin therapy undergo invasive and expensive checks for the coagulability of their blood. No information on coagulation levels is currently available between two controls. METHODOLOGY: A method was developed to determine warfarin in oral fluid by HPLC and fluorimetric detection. The chromatographic separation was performed at room temperature on a C-18 reversed-phase column, 65% PBS and 35% methanol mobile phase, flow rate 0.7 mL/min, injection volume 25 µL, excitation wavelength 310 nm, emission wavelength 400 nm. FINDINGS: The method was free from interference and matrix effect, linear in the range 0.2-100 ng/mL, with a detection limit of 0.2 ng/mL. Its coefficient of variation was <3% for intra-day measurements and <5% for inter-day measurements. The average concentration of warfarin in the oral fluid of 50 patients was 2.5±1.6 ng/mL (range 0.8-7.6 ng/mL). Dosage was not correlated to INR (r = -0.03, p = 0.85) but positively correlated to warfarin concentration in the oral fluid (r = 0.39, p = 0.006). The correlation between warfarin concentration and pH in the oral fluid (r = 0.37, p = 0.009) confirmed the importance of pH in regulating the drug transfer from blood. A correlation between warfarin concentration in the oral fluid and INR was only found in samples with pH values ≥7.2 (r = 0.84, p = 0.004). CONCLUSIONS: Warfarin diffuses from blood to oral fluid. The method allows to measure its concentration in this matrix and to analyze correlations with INR and other parameters

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
    • …
    corecore