88 research outputs found

    Constructing sonified haptic line graphs for the blind student: first steps

    Get PDF
    Line graphs stand as an established information visualisation and analysis technique taught at various levels of difficulty according to standard Mathematics curricula. It has been argued that blind individuals cannot use line graphs as a visualisation and analytic tool because they currently primarily exist in the visual medium. The research described in this paper aims at making line graphs accessible to blind students through auditory and haptic media. We describe (1) our design space for representing line graphs, (2) the technology we use to develop our prototypes and (3) the insights from our preliminary work

    Fixation-related Brain Potentials during Semantic Integration of Object–Scene Information

    Get PDF
    In vision science, a particularly controversial topic is whether and how quickly the semantic information about objects is available outside foveal vision. Here, we aimed at contributing to this debate by coregistering eye movements and EEG while participants viewed photographs of indoor scenes that contained a semantically consistent or inconsistent target object. Linear deconvolution modeling was used to analyze the ERPs evoked by scene onset as well as the fixation-related potentials (FRPs) elicited by the fixation on the target object (t) and by the preceding fixation (t − 1). Object–scene consistency did not influence the probability of immediate target fixation or the ERP evoked by scene onset, which suggests that object–scene semantics was not accessed immediately. However, during the subsequent scene exploration, inconsistent objects were prioritized over consistent objects in extrafoveal vision (i.e., looked at earlier) and were more effortful to process in foveal vision (i.e., looked at longer). In FRPs, we demonstrate a fixation-related N300/N400 effect, whereby inconsistent objects elicit a larger frontocentral negativity than consistent objects. In line with the behavioral findings, this effect was already seen in FRPs aligned to the pretarget fixation t − 1 and persisted throughout fixation t, indicating that the extraction of object semantics can already begin in extrafoveal vision. Taken together, the results emphasize the usefulness of combined EEG/eye movement recordings for understanding the mechanisms of object–scene integration during natural viewing

    Friction reduction and zero wear for 52100 bearing steel by high‐dose implantation of carbon

    Get PDF
    Ion implantation of carbon in the AISI 52100 bearing steel yields a distinct reduction in friction and wear. This improvement is strongly dependent on the implanted fluence. The coefficient of friction decreases from 0.6 to 0.2 for doses >1×1018 cm-2 (energy 100 keV) and a wear reduction to nearly ‘‘zero wear’’ was obtainable even under severe wear conditions. The counterpart (unimplanted AISI 52100 steel ball) shows a similar behavior, which demonstrates that the tribological system is totally changed. Mössbauer spectroscopy and x-ray diffraction revealed that hexagonal Âż-carbide is formed on implantation. On the other hand, Rutherford backscattering spectrometry shows that for high doses a large fraction of the implanted carbon is not contained in this carbide

    Comparison of magnetic resonance imaging and computed tomography for breast target volume delineation in prone and supine positions

    Get PDF
    Purpose To\ua0determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57\ua0(95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52\ua0(95% CI 0.48-0.56) for MRI supine, 0.56\ua0(95% CI 0.53-0.59) for CT prone and 0.55\ua0(95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41\ua0(95% CI 0.36-0.46) for supine and 0.38\ua0(0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images

    A co-registration investigation of inter-word spacing and parafoveal preview: Eye movements and fixation-related potentials

    Get PDF
    Participants’ eye movements (EMs) and EEG signal were simultaneously recorded to examine foveal and parafoveal processing during sentence reading. All the words in the sentence were manipulated for inter-word spacing (intact spaces vs. spaces replaced by a random letter) and parafoveal preview (identical preview vs. random letter string preview). We observed disruption for unspaced text and invalid preview conditions in both EMs and fixation-related potentials (FRPs). Unspaced and invalid preview conditions received longer reading times than spaced and valid preview conditions. In addition, the FRP data showed that unspaced previews disrupted reading in earlier time windows of analysis, compared to string preview conditions. Moreover, the effect of parafoveal preview was greater for spaced relative to unspaced conditions, in both EMs and FRPs. These findings replicate well-established preview effects, provide novel insight into the neural correlates of reading with and without inter-word spacing and suggest that spatial selection precedes lexical processing

    Covert Tracking: A Combined ERP and Fixational Eye Movement Study

    Get PDF
    Attention can be directed to particular spatial locations, or to objects that appear at anticipated points in time. While most work has focused on spatial or temporal attention in isolation, we investigated covert tracking of smoothly moving objects, which requires continuous coordination of both. We tested two propositions about the neural and cognitive basis of this operation: first that covert tracking is a right hemisphere function, and second that pre-motor components of the oculomotor system are responsible for driving covert spatial attention during tracking. We simultaneously recorded event related potentials (ERPs) and eye position while participants covertly tracked dots that moved leftward or rightward at 12 or 20°/s. ERPs were sensitive to the direction of target motion. Topographic development in the leftward motion was a mirror image of the rightward motion, suggesting that both hemispheres contribute equally to covert tracking. Small shifts in eye position were also lateralized according to the direction of target motion, implying covert activation of the oculomotor system. The data addresses two outstanding questions about the nature of visuospatial tracking. First, covert tracking is reliant upon a symmetrical frontoparietal attentional system, rather than being right lateralized. Second, this same system controls both pursuit eye movements and covert tracking

    Guidelines for management of ischaemic stroke and transient ischaemic attack 2008

    Get PDF
    This article represents the update of the European Stroke Initiative Recommendations for Stroke Management. These guidelines cover both ischaemic stroke and transient ischaemic attacks, which are now considered to be a single entity. The article covers referral and emergency management, Stroke Unit service, diagnostics, primary and secondary prevention, general stroke treatment, specific treatment including acute management, management of complications, and rehabilitation
    • 

    corecore