364 research outputs found

    Stripping #The Dress: the importance of contextual information on inter-individual differences in colour perception.

    Get PDF
    In 2015, a picture of a Dress (henceforth the Dress) triggered popular and scientific interest; some reported seeing the Dress in white and gold (W&G) and others in blue and black (B&B). We aimed to describe the phenomenon and investigate the role of contextualization. Few days after the Dress had appeared on the Internet, we projected it to 240 students on two large screens in the classroom. Participants reported seeing the Dress in B&B (48%), W&G (38%), or blue and brown (B&Br; 7%). Amongst numerous socio-demographic variables, we only observed that W&G viewers were most likely to have always seen the Dress as W&G. In the laboratory, we tested how much contextual information is necessary for the phenomenon to occur. Fifty-seven participants selected colours most precisely matching predominant colours of parts or the full Dress. We presented, in this order, small squares (a), vertical strips (b), and the full Dress (c). We found that (1) B&B, B&Br, and W&G viewers had selected colours differing in lightness and chroma levels for contextualized images only (b, c conditions) and hue for fully contextualized condition only (c) and (2) B&B viewers selected colours most closely matching displayed colours of the Dress. Thus, the Dress phenomenon emerges due to inter-individual differences in subjectively perceived lightness, chroma, and hue, at least when all aspects of the picture need to be integrated. Our results support the previous conclusions that contextual information is key to colour perception; it should be important to understand how this actually happens

    Evidence for a shared etiological mechanism of psychotic symptoms and obsessive-compulsive symptoms in patients with psychotic disorders and their siblings

    Get PDF
    The prevalence of obsessive-compulsive disorder in subjects with psychotic disorder is much higher than in the general population. The higher than chance co-occurrence has also been demonstrated at the level of subclinical expression of both phenotypes. Both extended phenotypes have been shown to cluster in families. However, little is known about the origins of their elevated co-occurrence. In the present study, evidence for a shared etiological mechanism was investigated in 3 samples with decreasing levels of familial psychosis liability: 987 patients, 973 of their unaffected siblings and 566 healthy controls. The association between the obsessive-compulsive phenotype and the psychosis phenotype c.q. psychosis liability was investigated. First, the association was assessed between (subclinical) obsessive-compulsive symptoms and psychosis liability. Second, in a cross-sib cross-trait analysis, it was examined whether (subclinical) obsessive-compulsive symptoms in the patient were associated with (subclinical) psychotic symptoms in the related unaffected sibling. Evidence was found for both associations, which is compatible with a partially shared etiological pathway underlying obsessive-compulsive and psychotic disorder. This is the first study that used a cross-sib cross-trait design in patients and unaffected siblings, thus circumventing confounding by disease-related factors present in clinical samples

    The COMPASS Experiment at CERN

    Get PDF
    The COMPASS experiment makes use of the CERN SPS high-intensitymuon and hadron beams for the investigation of the nucleon spin structure and the spectroscopy of hadrons. One or more outgoing particles are detected in coincidence with the incoming muon or hadron. A large polarized target inside a superconducting solenoid is used for the measurements with the muon beam. Outgoing particles are detected by a two-stage, large angle and large momentum range spectrometer. The setup is built using several types of tracking detectors, according to the expected incident rate, required space resolution and the solid angle to be covered. Particle identification is achieved using a RICH counter and both hadron and electromagnetic calorimeters. The setup has been successfully operated from 2002 onwards using a muon beam. Data with a hadron beam were also collected in 2004. This article describes the main features and performances of the spectrometer in 2004; a short summary of the 2006 upgrade is also given.Comment: 84 papes, 74 figure

    Impact of infection on proteome-wide glycosylation revealed by distinct signatures for bacterial and viral pathogens

    Get PDF
    Mechanisms of infection and pathogenesis have predominantly been studied based on differential gene or protein expression. Less is known about posttranslational modifications, which are essential for protein functional diversity. We applied an innovative glycoproteomics method to study the systemic proteome-wide glycosylation in response to infection. The protein site-specific glycosylation was characterized in plasma derived from well-defined controls and patients. We found 3862 unique features, of which we identified 463 distinct intact glycopeptides, that could be mapped to more than 30 different proteins. Statistical analyses were used to derive a glycopeptide signature that enabled significant differentiation between patients with a bacterial or viral infection. Furthermore, supported by a machine learning algorithm, we demonstrated the ability to identify the causative pathogens based on the distinctive host blood plasma glycopeptide signatures. These results illustrate that glycoproteomics holds enormous potential as an innovative approach to improve the interpretation of relevant biological changes in response to infection

    Circulating Apoptotic Progenitor Cells in Patients with Congestive Heart Failure

    Get PDF
    Background: Circulating CD34+ endothelial progenitor cells (EPCs) are capable of differentiating into mature endothelial cells to assist in angiogenesis and vasculogenesis. We sought to quantify the numbers of apoptotic progenitors in patients with congestive heart failure. Methods and Results: Peripheral blood mononuclear cells were isolated by Ficoll density-gradient from 58 patients with various degrees of heart failure and 23 matched controls. Apoptosis in progenitor CD34+ cells was assessed using the Annexin V-PE/PI detection kit, and FACS analysis was performed with triple staining for CD34, annexin-V and propidium iodide. The percentage of early and late apoptotic progenitor cells was determined in the subject groups and was correlated with clinical characteristics. While there was no significant difference in total CD34 positive cells or early apoptotic progenitors between control subjects and CHF patients (p = 0.42) or between severe and mild/moderate CHF groups (p = 0.544), there was an elevated number of late apoptotic progenitors in the severe CHF group compared with the mild/moderate CHF group (p = 0.03). Late apoptotic progenitors were significantly increased in CHF patients as compared to matched controls. There was also an inverse correlation between late apoptotic progenitors and ejection fraction (r = 20.252, p = 0.028) as well as a positive association with NYHA class (r = 0.223, p = 0.046). Conclusion: Severe heart failure patients exhibited higher numbers of late apoptotic progenitors, and this was positivel

    Patient safety in remote primary care encounters: multimethod qualitative study combining Safety I and Safety II analysis

    Get PDF
    Abstract Background Triage and clinical consultations increasingly occur remotely. We aimed to learn why safety incidents occur in remote encounters and how to prevent them. Setting and sample UK primary care. 95 safety incidents (complaints, settled indemnity claims and reports) involving remote interactions. Separately, 12 general practices followed 2021–2023. Methods Multimethod qualitative study. We explored causes of real safety incidents retrospectively (‘Safety I’ analysis). In a prospective longitudinal study, we used interviews and ethnographic observation to produce individual, organisational and system-level explanations for why safety and near-miss incidents (rarely) occurred and why they did not occur more often (‘Safety II’ analysis). Data were analysed thematically. An interpretive synthesis of why safety incidents occur, and why they do not occur more often, was refined following member checking with safety experts and lived experience experts. Results Safety incidents were characterised by inappropriate modality, poor rapport building, inadequate information gathering, limited clinical assessment, inappropriate pathway (eg, wrong algorithm) and inadequate attention to social circumstances. These resulted in missed, inaccurate or delayed diagnoses, underestimation of severity or urgency, delayed referral, incorrect or delayed treatment, poor safety netting and inadequate follow-up. Patients with complex pre-existing conditions, cardiac or abdominal emergencies, vague or generalised symptoms, safeguarding issues, failure to respond to previous treatment or difficulty communicating seemed especially vulnerable. General practices were facing resource constraints, understaffing and high demand. Triage and care pathways were complex, hard to navigate and involved multiple staff. In this context, patient safety often depended on individual staff taking initiative, speaking up or personalising solutions. Conclusion While safety incidents are extremely rare in remote primary care, deaths and serious harms have resulted. We offer suggestions for patient, staff and system-level mitigations

    X-shooter, the new wide band intermediate resolution spectrograph at the ESO Very Large Telescope

    Get PDF
    X-shooter is the first 2nd generation instrument of the ESO Very Large Telescope(VLT). It is a very efficient, single-target, intermediate-resolution spectrograph that was installed at the Cassegrain focus of UT2 in 2009. The instrument covers, in a single exposure, the spectral range from 300 to 2500 nm. It is designed to maximize the sensitivity in this spectral range through dichroic splitting in three arms with optimized optics, coatings, dispersive elements and detectors. It operates at intermediate spectral resolution (R~4,000 - 17,000, depending on wavelength and slit width) with fixed echelle spectral format (prism cross-dispersers) in the three arms. It includes a 1.8"x4" Integral Field Unit as an alternative to the 11" long slits. A dedicated data reduction package delivers fully calibrated two-dimensional and extracted spectra over the full wavelength range. We describe the main characteristics of the instrument and present its performance as measured during commissioning, science verification and the first months of science operations.Comment: accepted for publication in A&

    Emotional design and human-robot interaction

    Get PDF
    Recent years have shown an increase in the importance of emotions applied to the Design field - Emotional Design. In this sense, the emotional design aims to elicit (e.g., pleasure) or prevent (e.g., displeasure) determined emotions, during human product interaction. That is, the emotional design regulates the emotional interaction between the individual and the product (e.g., robot). Robot design has been a growing area whereby robots are interacting directly with humans in which emotions are essential in the interaction. Therefore, this paper aims, through a non-systematic literature review, to explore the application of emotional design, particularly on Human-Robot Interaction. Robot design features (e.g., appearance, expressing emotions and spatial distance) that affect emotional design are introduced. The chapter ends with a discussion and a conclusion.info:eu-repo/semantics/acceptedVersio

    The Next Generation of Axion Helioscopes: The International Axion Observatory (IAXO)

    Get PDF
    The International Axion Observatory (IAXO) is a proposed 4th-generation axion helioscope with the primary physics research goal to search for solar axions via their Primakoff conversion into photons of 1 \u2013 10 keV energies in a strong magnetic field. IAXO will achieve a sensitivity to the axion-photon coupling ga\u3b3 down to a few 710 1212 GeV 121 for a wide range of axion masses up to 3c 0.25 eV. This is an improvement over the currently best (3rd generation) axion helioscope, the CERN Axion Solar Telescope (CAST), of about 5 orders of magnitude in signal strength, corresponding to a factor 3c 20 in the axion photon coupling. IAXO's sensitivity relies on the construction of a large superconducting 8-coil toroidal magnet of 20 m length optimized for axion research. Each of the eight 60 cm diameter magnet bores is equipped with x-ray optics focusing the signal photons into 3c 0.2 cm2 spots that are imaged by very low background x-ray detectors. The magnet will be built into a structure with elevation and azimuth drives that will allow solar tracking for 12 hours each day. This contribution is a summary of our papers [1], [2] and [3] and we refer to these for further details
    corecore