722 research outputs found
Cavitation of Electrons Bubbles in Liquid Helium Below saturation Pressure
We have used a Hartree-type electron-helium potential together with a density
functional description of liquid He and He to study the explosion of
electron bubbles submitted to a negative pressure. The critical pressure at
which bubbles explode has been determined as a function of temperature. It has
been found that this critical pressure is very close to the pressure at which
liquid helium becomes globally unstable in the presence of electrons. It is
shown that at high temperatures the capillary model overestimates the critical
pressures. We have checked that a commonly used and rather simple
electron-helium interaction yields results very similar to those obtained using
the more accurate Hartree-type interaction. We have estimated that the
crossover temperature for thermal to quantum nucleation of electron bubbles is
very low, of the order of 6 mK for He.Comment: 22 pages, 9 figure
Interpretation of evidence in data by untrained medical students: a scenario-based study
<p>Abstract</p> <p>Background</p> <p>To determine which approach to assessment of evidence in data - statistical tests or likelihood ratios - comes closest to the interpretation of evidence by untrained medical students.</p> <p>Methods</p> <p>Empirical study of medical students (N = 842), untrained in statistical inference or in the interpretation of diagnostic tests. They were asked to interpret a hypothetical diagnostic test, presented in four versions that differed in the distributions of test scores in diseased and non-diseased populations. Each student received only one version. The intuitive application of the statistical test approach would lead to rejecting the null hypothesis of no disease in version A, and to accepting the null in version B. Application of the likelihood ratio approach led to opposite conclusions - against the disease in A, and in favour of disease in B. Version C tested the importance of the p-value (A: 0.04 versus C: 0.08) and version D the importance of the likelihood ratio (C: 1/4 versus D: 1/8).</p> <p>Results</p> <p>In version A, 7.5% concluded that the result was in favour of disease (compatible with p value), 43.6% ruled against the disease (compatible with likelihood ratio), and 48.9% were undecided. In version B, 69.0% were in favour of disease (compatible with likelihood ratio), 4.5% against (compatible with p value), and 26.5% undecided. Increasing the p value from 0.04 to 0.08 did not change the results. The change in the likelihood ratio from 1/4 to 1/8 increased the proportion of non-committed responses.</p> <p>Conclusions</p> <p>Most untrained medical students appear to interpret evidence from data in a manner that is compatible with the use of likelihood ratios.</p
Effectiveness of bisphosphonates on nonvertebral and hip fractures in the first year of therapy: The risedronate and alendronate (REAL) cohort study
INTRODUCTION: Randomized clinical trials have shown that risedronate and alendronate reduce fractures among women with osteoporosis. The aim of this observational study was to observe, in clinical practice, the incidence of hip and nonvertebral fractures among women in the year following initiation of once-a-week dosing of either risedronate or alendronate. METHODS: Using records of health service utilization from July 2002 through September 2004, we created two cohorts: women (ages 65 and over) receiving risedronate (nâ=â12,215) or alendronate (nâ=â21,615). Cox proportional hazard modeling was used to compare the annual incidence of nonvertebral fractures and of hip fractures between cohorts, adjusting for potential differences in risk factors for fractures. RESULTS: There were 507 nonvertebral fractures and 109 hip fractures. Through one year of therapy, the incidence of nonvertebral fractures in the risedronate cohort (2.0%) was 18% lower (95% CI 2% â 32%) than in the alendronate cohort (2.3%). The incidence of hip fractures in the risedronate cohort (0.4%) was 43% lower (95% CI 13% â 63%) than in the alendronate cohort (0.6%). These results were consistent across a number of sensitivity analyses. CONCLUSION: Patients receiving risedronate have lower rates of hip and nonvertebral fractures during their first year of therapy than patients receiving alendronate
Women and postfertilization effects of birth control: consistency of beliefs, intentions and reported use
BACKGROUND: This study assesses the consistency of responses among women regarding their beliefs about the mechanisms of actions of birth control methods, beliefs about when human life begins, the intention to use or not use birth control methods that they believe may act after fertilization or implantation, and their reported use of specific methods. METHODS: A questionnaire was administered in family practice and obstetrics and gynecology clinics in Salt Lake City, Utah, and Tulsa, Oklahoma. Participants included women ages 18â50 presenting for any reason and women under age 18 presenting for family planning or pregnancy care. Analyses were based on key questions addressing beliefs about whether specific birth control methods may act after fertilization, beliefs about when human life begins, intention to use a method that may act after fertilization, and reported use of specific methods. The questionnaire contained no information about the mechanism of action of any method of birth control. Responses were considered inconsistent if actual use contradicted intentions, if one intention contradicted another, or if intentions contradicted beliefs. RESULTS: Of all respondents, 38% gave consistent responses about intention to not use or to stop use of any birth control method that acted after fertilization, while 4% gave inconsistent responses. The corresponding percentages for birth control methods that work after implantation were 64% consistent and 2% inconsistent. Of all respondents, 34% reported they believed that life begins at fertilization and would not use any birth control method that acts after fertilization (a consistent response), while 3% reported they believed that life begins at fertilization but would use a birth control method that acts after fertilization (inconsistent). For specific methods of birth control, less than 1% of women gave inconsistent responses. A majority of women (68% or greater) responded accurately about the mechanism of action of condoms, abstinence, sterilization, and abortion, but a substantial percentage of women (between 19% and 57%) were uncertain about the mechanisms of action of oral contraceptives, intrauterine devices (IUDs), Depo-Provera, or natural family planning. CONCLUSION: Women who believe that life begins at fertilization may not intend to use a birth control method that could have postfertilization effects. More research is needed to understand the relative importance of postfertilization effects for women in other populations, and in relation to other properties of and priorities for birth control methods. However, many women were uncertain about the mechanisms of action of specific methods. To respect the principles of informed consent, some women may need more education about what is known and not known about the mechanisms of action of birth control methods
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV
The performance of muon reconstruction, identification, and triggering in CMS
has been studied using 40 inverse picobarns of data collected in pp collisions
at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection
criteria covering a wide range of physics analysis needs have been examined.
For all considered selections, the efficiency to reconstruct and identify a
muon with a transverse momentum pT larger than a few GeV is above 95% over the
whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4,
while the probability to misidentify a hadron as a muon is well below 1%. The
efficiency to trigger on single muons with pT above a few GeV is higher than
90% over the full eta range, and typically substantially better. The overall
momentum scale is measured to a precision of 0.2% with muons from Z decays. The
transverse momentum resolution varies from 1% to 6% depending on pseudorapidity
for muons with pT below 100 GeV and, using cosmic rays, it is shown to be
better than 10% in the central region up to pT = 1 TeV. Observed distributions
of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO
Differences in persistence, safety and efficacy of generic and original branded once weekly bisphosphonates in patients with postmenopausal osteoporosis: 1-year results of a retrospective patient chart review analysis
X-ray emission from the Sombrero galaxy: discrete sources
We present a study of discrete X-ray sources in and around the
bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival
Chandra observations with a total exposure of ~200 ks. With a detection limit
of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30
kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler
et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS
observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray
binaries (LMXBs). We quantify the differential luminosity functions (LFs) for
both the detected GC and field LMXBs, whose power-low indices (~1.1 for the
GC-LF and ~1.6 for field-LF) are consistent with previous studies for
elliptical galaxies. With precise sky positions of the GCs without a detected
X-ray source, we further quantify, through a fluctuation analysis, the GC LF at
fainter luminosities down to 1E35 erg/s. The derived index rules out a
faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent
findings in several elliptical galaxies and the bulge of M31. On the other
hand, the 2-6 keV unresolved emission places a tight constraint on the field
LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101
sources in the halo of Sombrero. The presence of these sources cannot be
interpreted as galactic LMXBs whose spatial distribution empirically follows
the starlight. Their number is also higher than the expected number of cosmic
AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray
surveys. We suggest that either the cosmic X-ray background is unusually high
in the direction of Sombrero, or a distinct population of X-ray sources is
present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres
Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV
The azimuthal anisotropy of charged particles in PbPb collisions at
nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS
detector at the LHC over an extended transverse momentum (pt) range up to
approximately 60 GeV. The data cover both the low-pt region associated with
hydrodynamic flow phenomena and the high-pt region where the anisotropies may
reflect the path-length dependence of parton energy loss in the created medium.
The anisotropy parameter (v2) of the particles is extracted by correlating
charged tracks with respect to the event-plane reconstructed by using the
energy deposited in forward-angle calorimeters. For the six bins of collision
centrality studied, spanning the range of 0-60% most-central events, the
observed v2 values are found to first increase with pt, reaching a maximum
around pt = 3 GeV, and then to gradually decrease to almost zero, with the
decline persisting up to at least pt = 40 GeV over the full centrality range
measured.Comment: Replaced with published version. Added journal reference and DO
- âŚ