64 research outputs found

    Presbiphonia as a cause of glotic insufficiency

    Get PDF
    Introduction and objective: The aging of the voice has become a frequent cause of consultation in the otolaryngologist's daily practice, due to the progressive aging of the population and societies of industrialized countries. With this review, we intend to update the clinical and pathological changes of the larynx that lead to presbyphonia, addressing the most relevant aspects about its causes, clinical manifestations and therapeutic measures. Materials and methods: descriptive and narrative literature review, result of the bibliographic search in the database PubMed with the descriptors strategies [(presbyphonia OR aging voice disorders) AND vocal atrophy]. Revisions, clinical trials and general articles in both english and spanish were selected for the past 10 years. Clinical cases, articles of glottic insufficiency or dysphonia due to other causes were excluded. Results: The systematic review offered 34 articles, of which, 17 met the inclusion criteria. The results should be interpreted with optimism, despite its variability; the presbyphonia is a growing diagnosis, with a greater rise among otorhinolaryngologists dedicated to laryngology. Conclusions: We perform a review on the most relevant aspects regarding the clinical, endoscopic and anatomical findings that occur in presbyphonia. We present the different forms of treatment proposed so far to minimize glottic insufficiency and improve vocal competence in aged people.Introducción y objetivo: El envejecimiento de la voz se ha convertido en una causa frecuente de consulta en la práctica diaria del otorrinolaringólogo, debido entre otras causas al envejecimiento progresivo de la población y sociedades de los países industrializados. Con este trabajo de revisión pretendemos una puesta al día en relación a los cambios clínicos y patológicos de la laringe que conllevan a la presbifonía, abordando los aspectos más relevantes sobre sus causas, manifestaciones clínicas y medidas terapéuticas. Materiales y métodos: trabajo descriptivo, resultado de la búsqueda bibliográfica en la base de datos PubMed con las estrategias de búsqueda [(presbyphonia OR aging voice disorders) AND vocal atrophy]. Se seleccionaron revisiones, ensayos clínicos y artículos en inglés y español de los últimos 10 años. Se excluyeron casos clínicos, artículos de insuficiencia glótica o disfonía por otras causas. Resultados: La revisión sistemática ofreció 34 artículos, de los cuales, 17 cumplieron los criterios de inclusión. Los resultados deben interpretarse con optimismo, a pesar de su variabilidad la presbifonía es un diagnóstico en crecimiento, con mayor auge entre otorrinolaringólogos dedicados a laringología. Conclusiones: Realizamos una revisión sobre los aspectos más relevantes en relación a los hallazgos clínicos, endoscópicos y anatómicos que ocurren en la presbifonía. Presentamos las diferentes formas de tratamiento propuestas hasta ahora para minimizar la insuficiencia glótica y mejorar la competencia vocal en personas envejecidas

    Randomized-controlled trial of the DIALIVE liver dialysis device vs. standard of care in patients with acute-on-chronic liver failure

    Get PDF
    BACKGROUND AND AIMS: Acute on chronic liver failure (ACLF) is characterized by severe systemic inflammation, multi-organ failure and high mortality rates. Its treatment is an urgent unmet need. DIALIVE is a novel liver dialysis device that aims to exchange d ysfunctional albumin and remove damage- and pathogen-associated molecular patterns. This first-in-man randomized, controlled clinical trial was performed with the primary aim of assessing its safety in ACLF patients with secondary aims to evaluate its clinical effects, device performance and effect on pathophysiologically-relevant biomarkers. METHODS: 32 alcoholic cirrhosis patients with ACLF were included. Patients were treated with DIALIVE for up to 5-days and end points were assessed at Day-10. Safety was assessed in all patients (n=32). The secondary aims were assessed in a pre-specified subgroup that had at least 3-treatment sessions with DIALIVE (n=30). RESULTS: There were no significant differences in 28-day mortality or occurrence of serious adverse events between the groups. Significant reduction in the severity of endotoxemia and improvement in albumin function was observed in DIALIVE group, which translated into a significant reduction in the CLIF-C (Chronic Liver Failure consortium) organ failure (p=0.018) and CLIF-C ACLF scores (p=0.042) at Day-10. Time to resolution of ACLF was significantly faster in DIALIVE group (p=0.036). Biomarkers of systemic inflammation such as IL-8 (p=0.006), cell death [cytokeratin-18: M30 (p=0.005) and M65 (p=0.029)], endothelial function [asymmetric dimethylarginine (p=0.002)] and, ligands for toll-like receptor 4 (p=0.030) and inflammasome (p=0.002) improved significantly in DIALIVE group. CONCLUSIONS: These data indicate that DIALIVE appears to be safe and impacts positively on prognostic scores and pathophysiologically relevant biomarkers in patients with ACLF. Larger, adequately powered studies are warranted to further confirm its safety and efficacy. LAY SUMMARY: This is the first-in-man clinical trial which tested DIALIVE, a novel liver dialysis device for the treatment of liver cirrhosis and acute on chronic liver failure, a condition associated with severe inflammation, organ failures and a high risk of death. The study met the primary end point confirming DIALIVE system to be safe. Additionally, it reduced inflammation with improved clinical parameters. It did not, however, reduce mortality in this small study and requires further larger clinical trials to re-confirm its safety and evaluate efficacy. CLINICAL TRIAL NUMBER: NCT03065699

    Surgical treatment for colorectal cancer: Analysis of the influence of an enhanced recovery programme on long-term oncological outcomes-a study protocol for a prospective, multicentre, observational cohort study

    Full text link
    Introduction The evidence currently available from enhanced recovery after surgery (ERAS) programmes concerns their benefits in the immediate postoperative period, but there is still very little evidence as to whether their correct implementation benefits patients in the long term. The working hypothesis here is that, due to the lower response to surgical aggression and lower rates of postoperative complications, ERAS protocols can reduce colorectal cancer-related mortality. The main objective of this study is to analyse the impact of an ERAS programme for colorectal cancer on 5-year survival. As secondary objectives, we propose to analyse the weight of each of the predefined items in the oncological results as well as the quality of life. Methods and analysis A multicentre prospective cohort study was conducted in patients older than 18 years of age who are scheduled to undergo surgery for colorectal cancer. The study involved 12 hospitals with an implemented enhanced recovery protocol according to the guidelines published by the Spanish National Health Service. The intervention group includes patients with a minimum implementation level of 70%, and the control group includes those who fail to reach this level. Compliance will be studied using 18 key performance indicators, and the results will be analysed using cancer survival indicators, including overall survival, cancer-specific survival and relapse-free survival. The time to recurrence, perioperative morbidity and mortality, hospital stay and quality of life will also be studied, the latter using the validated EuroQol Five questionnaire. The propensity index method will be used to create comparable treatment and control groups, and a multivariate regression will be used to study each variable. The Kaplan-Meier estimator will be used to estimate survival and the log-rank test to make comparisons. A p value of less than 0.05 (two-tailed) will be considered to be significant. Ethics and dissemination Ethical approval for this study was obtained from the Aragon Ethical Committee (C.P.-C.I. PI20/086) on 4 March 2020. The findings of this study will be submitted to peer-reviewed journals (BMJ Open, JAMA Surgery, Annals of Surgery, British Journal of Surgery). Abstracts will be submitted to relevant national and international meetings.The present research study was awarded a Ministerio de Ciencia e Innovación health research project grant (PI19/00291) from the Carlos III Institute of the Spanish National Health Service as part of the 2019 call for Strategic Action in Health

    Using Interpretable Machine Learning to Identify Baseline Predictive Factors of Remission and Drug Durability in Crohn’s Disease Patients on Ustekinumab

    Get PDF
    Ustekinumab has shown efficacy in Crohn's Disease (CD) patients. To identify patient profiles of those who benefit the most from this treatment would help to position this drug in the therapeutic paradigm of CD and generate hypotheses for future trials. The objective of this analysis was to determine whether baseline patient characteristics are predictive of remission and the drug durability of ustekinumab, and whether its positioning with respect to prior use of biologics has a significant effect after correcting for disease severity and phenotype at baseline using interpretable machine learning. Patients' data from SUSTAIN, a retrospective multicenter single-arm cohort study, were used. Disease phenotype, baseline laboratory data, and prior treatment characteristics were documented. Clinical remission was defined as the Harvey Bradshaw Index <= 4 and was tracked longitudinally. Drug durability was defined as the time until a patient discontinued treatment. A total of 439 participants from 60 centers were included and a total of 20 baseline covariates considered. Less exposure to previous biologics had a positive effect on remission, even after controlling for baseline disease severity using a non-linear, additive, multivariable model. Additionally, age, body mass index, and fecal calprotectin at baseline were found to be statistically significant as independent negative risk factors for both remission and drug survival, with further risk factors identified for remission

    Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries

    Get PDF
    Abstract Background Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres. Methods This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries. Results In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia. Conclusion This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries

    25th annual computational neuroscience meeting: CNS-2016

    Get PDF
    The same neuron may play different functional roles in the neural circuits to which it belongs. For example, neurons in the Tritonia pedal ganglia may participate in variable phases of the swim motor rhythms [1]. While such neuronal functional variability is likely to play a major role the delivery of the functionality of neural systems, it is difficult to study it in most nervous systems. We work on the pyloric rhythm network of the crustacean stomatogastric ganglion (STG) [2]. Typically network models of the STG treat neurons of the same functional type as a single model neuron (e.g. PD neurons), assuming the same conductance parameters for these neurons and implying their synchronous firing [3, 4]. However, simultaneous recording of PD neurons shows differences between the timings of spikes of these neurons. This may indicate functional variability of these neurons. Here we modelled separately the two PD neurons of the STG in a multi-neuron model of the pyloric network. Our neuron models comply with known correlations between conductance parameters of ionic currents. Our results reproduce the experimental finding of increasing spike time distance between spikes originating from the two model PD neurons during their synchronised burst phase. The PD neuron with the larger calcium conductance generates its spikes before the other PD neuron. Larger potassium conductance values in the follower neuron imply longer delays between spikes, see Fig. 17.Neuromodulators change the conductance parameters of neurons and maintain the ratios of these parameters [5]. Our results show that such changes may shift the individual contribution of two PD neurons to the PD-phase of the pyloric rhythm altering their functionality within this rhythm. Our work paves the way towards an accessible experimental and computational framework for the analysis of the mechanisms and impact of functional variability of neurons within the neural circuits to which they belong

    Omecamtiv mecarbil in chronic heart failure with reduced ejection fraction, GALACTIC‐HF: baseline characteristics and comparison with contemporary clinical trials

    Get PDF
    Aims: The safety and efficacy of the novel selective cardiac myosin activator, omecamtiv mecarbil, in patients with heart failure with reduced ejection fraction (HFrEF) is tested in the Global Approach to Lowering Adverse Cardiac outcomes Through Improving Contractility in Heart Failure (GALACTIC‐HF) trial. Here we describe the baseline characteristics of participants in GALACTIC‐HF and how these compare with other contemporary trials. Methods and Results: Adults with established HFrEF, New York Heart Association functional class (NYHA) ≥ II, EF ≤35%, elevated natriuretic peptides and either current hospitalization for HF or history of hospitalization/ emergency department visit for HF within a year were randomized to either placebo or omecamtiv mecarbil (pharmacokinetic‐guided dosing: 25, 37.5 or 50 mg bid). 8256 patients [male (79%), non‐white (22%), mean age 65 years] were enrolled with a mean EF 27%, ischemic etiology in 54%, NYHA II 53% and III/IV 47%, and median NT‐proBNP 1971 pg/mL. HF therapies at baseline were among the most effectively employed in contemporary HF trials. GALACTIC‐HF randomized patients representative of recent HF registries and trials with substantial numbers of patients also having characteristics understudied in previous trials including more from North America (n = 1386), enrolled as inpatients (n = 2084), systolic blood pressure &lt; 100 mmHg (n = 1127), estimated glomerular filtration rate &lt; 30 mL/min/1.73 m2 (n = 528), and treated with sacubitril‐valsartan at baseline (n = 1594). Conclusions: GALACTIC‐HF enrolled a well‐treated, high‐risk population from both inpatient and outpatient settings, which will provide a definitive evaluation of the efficacy and safety of this novel therapy, as well as informing its potential future implementation

    Observation of gravitational waves from the coalescence of a 2.5−4.5 M⊙ compact object and a neutron star

    Get PDF

    Ultralight vector dark matter search using data from the KAGRA O3GK run

    Get PDF
    Among the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for U(1)B−L gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the U(1)B−L gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM

    Search for gravitational-lensing signatures in the full third observing run of the LIGO-Virgo network

    Get PDF
    Gravitational lensing by massive objects along the line of sight to the source causes distortions of gravitational wave-signals; such distortions may reveal information about fundamental physics, cosmology and astrophysics. In this work, we have extended the search for lensing signatures to all binary black hole events from the third observing run of the LIGO--Virgo network. We search for repeated signals from strong lensing by 1) performing targeted searches for subthreshold signals, 2) calculating the degree of overlap amongst the intrinsic parameters and sky location of pairs of signals, 3) comparing the similarities of the spectrograms amongst pairs of signals, and 4) performing dual-signal Bayesian analysis that takes into account selection effects and astrophysical knowledge. We also search for distortions to the gravitational waveform caused by 1) frequency-independent phase shifts in strongly lensed images, and 2) frequency-dependent modulation of the amplitude and phase due to point masses. None of these searches yields significant evidence for lensing. Finally, we use the non-detection of gravitational-wave lensing to constrain the lensing rate based on the latest merger-rate estimates and the fraction of dark matter composed of compact objects
    corecore