1,056 research outputs found

    Gas Explosions in Partially Filled, Large Twin Enclosures Connected with an Open Door and Having Variable Vent Sizes on Both Compartments

    Get PDF
    Accidental gas explosions are a recognised hazard in process industries but they are also common in residential buildings. Whilst process plants have specifically designed vent reliefs to limit the enclosure damage, in homes a similar effect is achieved due to the presence of doors and windows whose failure often protects the building. There are empirically based correlations for predicting overpressure and for vent sizing, however these are limited in application to simple enclosures. In practice, enclosures have interconnected spaces which would potentially increase the flame acceleration considerably. In this paper we present the results of full scale natural gas layer tests in a twin chamber, which consisted of two 22 m3 enclosures connected by an open doorway. Layered natural gas/air mixtures of 8, 10 and 12% by volume, were ignited at the rear of one of the chambers. Explosion relief was provided by vent openings of 2.48, 1.49 or 0.74 m2 on the far walls of both chambers. With tests with equal large vents on each of the chambers, the dominant influence was the external explosion. The maximum overpressure was produced by tests involving a 12% natural gas concentration. The use of a smaller vent in the adjoining enclosure had a significant effect on the maximum overpressure and the mechanism of the explosion development. However, altering the size from 1.49 m2 to 0.74 m2 had little overall effect. This was largely due to the greater generation of turbulence and the venting process which predominantly occurred via the doorway and through the ignition-chamber vent opening. The use of a smaller vent in the ignition enclosure also altered the manner in which the explosion developed. A venting driven ‘jetting’ expanding flame, propagated into the adjoining enclosure and towards the far vent opening, generating the dominant pressure peak in these type of tests

    Use of complementary and alternative medicine by those with a chronic disease and the general population - results of a national population based survey

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The use of complementary and alternative medicine (CAM) is becoming more common, but population-based descriptions of its patterns of use are lacking. This study aimed to determine the prevalence of CAM use in the general population and for those with asthma, diabetes, epilepsy and migraine.</p> <p>Methods</p> <p>Data from cycles 1.1, 2.1 and 3.1 of the Canadian Community Health Survey (CCHS) were used for the study. The CCHS is a national cross-sectional survey administered to 400,055 Canadians aged ≥12 between 2001-2005. Self-reported information about professionally diagnosed health conditions was elicited. CCHS surveys use a multistage stratified cluster design to randomly select a representative sample of Canadian household residents. Descriptive data on the utilization of CAM services was calculated and logistic regression was used to determine what sociodemographic factors predict CAM use.</p> <p>Results</p> <p>Weighted estimates show that 12.4% (95% Confidence Interval (CI): 12.2-12.5) of Canadians visited a CAM practitioner in the year they were surveyed; this rate was significantly higher for those with asthma 15.1% (95% CI: 14.5-15.7) and migraine 19.0% (95% CI: 18.4-19.6), and significantly lower for those with diabetes 8.0% (95% CI: 7.4-8.6) while the rate in those with epilepsy (10.3%, 95% CI: 8.4-12.2) was not significantly different from the general population.</p> <p>Conclusion</p> <p>A large proportion of Canadians use CAM services. Physicians should be aware that their patients may be accessing other services and should be prepared to ask and answer questions about the risks and benefits of CAM services in conjunction with standard medical care.</p

    Transmission of MDR and XDR Tuberculosis in Shanghai, China

    Get PDF
    Background: Multidrug-resistant (MDR) and extensively drug-resistant (XDR) tuberculosis (TB) are global health problems. We sought to determine the characteristics, prevalence, and relative frequency of transmission of MDR and XDR TB in Shanghai, one of the largest cities in Asia. Methods: TB is diagnosed in district TB hospitals in Shanghai, China. Drug susceptibility testing for first-line drugs was performed for all culture positive TB cases, and tests for second-line drugs were performed for MDR cases. VNTR-7 and VNTR-16 were used to genotype the strains, and prior treatment history and treatment outcomes were determined for each patient. Results: There were 4,379 culture positive TB cases diagnosed with drug susceptibility test results available during March 2004 through November 2007. 247 (5.6%) were infected with a MDR strain of M. tuberculosis and 11 (6.3%) of the 175 MDR patients whose isolate was tested for susceptibility to second-line drugs, were XDR. More than half of the patients with MDR and XDR were newly diagnosed and had no prior history of TB treatment. Nearly 57 % of the patients with MDR were successfully treated. Discussion: Transmission of MDR and XDR strains is a serious problem in Shanghai. While a history of prior anti-TB treatment indicates which individuals may have acquired MDR or XDR TB, it does not accurately predict which TB patients have disease caused by transmission of MDR and XDR strains. Therefore, universal drug susceptibility testing i

    Brain Abnormalities in Patients with Germline Variants in H3F3: Novel Imaging Findings and Neurologic Symptoms Beyond Somatic Variants and Brain Tumors

    Get PDF
    BACKGROUND AND PURPOSE: Pathogenic somatic variants affecting the genes Histone 3 Family 3A and 3B (H3F3) are extensively linked to the process of oncogenesis, in particular related to central nervous system tumors in children. Recently, H3F3 germline missense variants were described as the cause of a novel pediatric neurodevelopmental disorder. We aimed to investigate patterns of brain MR imaging of individuals carrying H3F3 germline variants. MATERIALS AND METHODS: In this retrospective study, we included individuals with proved H3F3 causative genetic variants and available brain MR imaging scans. Clinical and demographic data were retrieved from available medical records. Molecular genetic testing results were classified using the American College of Medical Genetics criteria for variant curation. Brain MR imaging abnormalities were analyzed according to their location, signal intensity, and associated clinical symptoms. Numeric variables were described according to their distribution, with median and interquartile range. RESULTS: Eighteen individuals (10 males, 56%) with H3F3 germline variants were included. Thirteen of 18 individuals (72%) presented with a small posterior fossa. Six individuals (33%) presented with reduced size and an internal rotational appearance of the heads of the caudate nuclei along with an enlarged and squared appearance of the frontal horns of the lateral ventricles. Five individuals (28%) presented with dysgenesis of the splenium of the corpus callosum. Cortical developmental abnormalities were noted in 8 individuals (44%), with dysgyria and hypoplastic temporal poles being the most frequent presentation. CONCLUSIONS: Imaging phenotypes in germline H3F3-affected individuals are related to brain features, including a small posterior fossa as well as dysgenesis of the corpus callosum, cortical developmental abnormalities, and deformity of lateral ventricles

    Zanamivir Conjugated to Poly-L-Glutamine is Much More Active Against Influenza Viruses in Mice and Ferrets Than the Drug Itself

    Get PDF
    Purpose: Previously, polymer-attached zanamivir had been found to inhibit influenza A viruses in vitro far better than did small-molecule zanamivir (1) itself. The aim of this study was to identify in vitro—using the plaque reduction assay—a highly potent 1-polymer conjugate, and subsequently test its antiviral efficacy in vivo. Methods: By examining the structure-activity relationship of 1-polymer conjugates in the plaque assay, we have determined that the most potent inhibitor against several representative influenza virus strains has a neutral high-molecular-weight backbone and a short alkyl linker. We have examined this optimal polymeric inhibitor for efficacy and immunogenicity in the mouse and ferret models of infection. Results: 1 attached to poly-L-glutamine is an effective therapeutic for established influenza infection in ferrets, reducing viral titers up to 30-fold for 6 days. There is also up to a 190-fold reduction in viral load when the drug is used as a combined prophylactic/therapeutic in mice. Additionally, we see no evidence that the drug conjugate stimulates an immune response in mice upon repeat administration. Conclusions: 1 attached to a neutral high-molecular-weight backbone through a short alkyl linker drastically reduced both in vitro and in vivo titers compared to those observed with 1 itself. Thus, further development of this polymeric zanamivir for the mitigation of influenza infection seems warranted.National Institutes of Health (U.S.) (Grant U01-AI074443

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO

    Search for new physics with same-sign isolated dilepton events with jets and missing transverse energy

    Get PDF
    A search for new physics is performed in events with two same-sign isolated leptons, hadronic jets, and missing transverse energy in the final state. The analysis is based on a data sample corresponding to an integrated luminosity of 4.98 inverse femtobarns produced in pp collisions at a center-of-mass energy of 7 TeV collected by the CMS experiment at the LHC. This constitutes a factor of 140 increase in integrated luminosity over previously published results. The observed yields agree with the standard model predictions and thus no evidence for new physics is found. The observations are used to set upper limits on possible new physics contributions and to constrain supersymmetric models. To facilitate the interpretation of the data in a broader range of new physics scenarios, information on the event selection, detector response, and efficiencies is provided.Comment: Published in Physical Review Letter
    corecore