237 research outputs found

    Recent Results on the Performance of the CMS Tracker Readout System

    Get PDF
    The CMS Silicon Tracker comprises a complicated set of hardware and software components that have been thoroughly tested at CERN before final integration of the Tracker. A vertical slice of the full readout chain has been operated under near-final conditions. In the absence of the tracker front-end modules, simulated events have been created within the FED (Front End Driver) and used to test the readout reliability and efficiency of the final DAQ (Data Acquisition). The data are sent over the S-Link 64 bit links to the FRL(Fast Readout Link) modules at rates in excess of 200 MBytes/s per FED depending on setup and conditions. The current tracker DAQ is fully based on the CMS communication and acquisition tool XDAQ. This paper discusses setup and results of a vertical slice of the full Tracker final readout system comprising 2 full crates of FEDs, 30 in total, read out through 1 full crate of final FRL modules. This test is to complement previous tests done at Imperial College[3] taking them to the next level in order to prove that a complete crate of FRLs using the final DAQ system, including all subcomponents of the final system both software and hardware with the exception of the detector modules themselves, is capable of sustained readout at the desired rates and occupancy of the CMS Tracker. Simulated data are created with varying hit occupancy (1-10%) and Poisson distributed trigger rates (<200KHz) and the resulting behaviour of the system is recorded. Data illustrating the performance of the system and data readout are presented

    Mass hierarchy discrimination with atmospheric neutrinos in large volume ice/water Cherenkov detectors

    Full text link
    Large mass ice/water Cherenkov experiments, optimized to detect low energy (1-20 GeV) atmospheric neutrinos, have the potential to discriminate between normal and inverted neutrino mass hierarchies. The sensitivity depends on several model and detector parameters, such as the neutrino flux profile and normalization, the Earth density profile, the oscillation parameter uncertainties, and the detector effective mass and resolution. A proper evaluation of the mass hierarchy discrimination power requires a robust statistical approach. In this work, the Toy Monte Carlo, based on an extended unbinned likelihood ratio test statistic, was used. The effect of each model and detector parameter, as well as the required detector exposure, was then studied. While uncertainties on the Earth density and atmospheric neutrino flux profiles were found to have a minor impact on the mass hierarchy discrimination, the flux normalization, as well as some of the oscillation parameter (\Delta m^2_{31}, \theta_{13}, \theta_{23}, and \delta_{CP}) uncertainties and correlations resulted critical. Finally, the minimum required detector exposure, the optimization of the low energy threshold, and the detector resolutions were also investigated.Comment: 23 pages, 16 figure

    The Antares Collaboration : Contributions to the 34th International Cosmic Ray Conference (ICRC 2015, The Hague)

    Get PDF
    The ANTARES detector, completed in 2008, is the largest neutrino telescope in the Northern hemisphere. Located at a depth of 2.5 km in the Mediterranean Sea, 40 km off the Toulon shore, its main goal is the search for astrophysical high energy neutrinos. In this paper we collect the 21 contributions of the ANTARES collaboration to the 34th International Cosmic Ray Conference (ICRC 2015). The scientific output is very rich and the contributions included in these proceedings cover the main physics results, ranging from steady point sources, diffuse searches, multi-messenger analyses to exotic physics

    Performance of the First ANTARES Detector Line

    Get PDF
    In this paper we report on the data recorded with the first Antares detector line. The line was deployed on the 14th of February 2006 and was connected to the readout two weeks later. Environmental data for one and a half years of running are shown. Measurements of atmospheric muons from data taken from selected runs during the first six months of operation are presented. Performance figures in terms of time residuals and angular resolution are given. Finally the angular distribution of atmospheric muons is presented and from this the depth profile of the muon intensity is derived.Comment: 14 pages, 9 figure

    Measurement of Atmospheric Neutrino Oscillations with the ANTARES Neutrino Telescope

    Get PDF
    The data taken with the ANTARES neutrino telescope from 2007 to 2010, a total live time of 863 days, are used to measure the oscillation parameters of atmospheric neutrinos. Muon tracks are reconstructed with energies as low as 20 GeV. Neutrino oscillations will cause a suppression of vertical upgoing muon neutrinos of such energies crossing the Earth. The parameters determining the oscillation of atmospheric neutrinos are extracted by fitting the event rate as a function of the ratio of the estimated neutrino energy and reconstructed flight path through the Earth. Measurement contours of the oscillation parameters in a two-flavour approximation are derived. Assuming maximum mixing, a mass difference of Δm322=(3.1±0.9)⋅10−3\Delta m_{32}^2=(3.1\pm 0.9)\cdot 10^{-3} eV2^2 is obtained, in good agreement with the world average value.Comment: 9 pages, 5 figure

    The ANTARES Optical Beacon System

    Get PDF
    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented.Comment: 21 pages, 18 figures, submitted to Nucl. Instr. and Meth. Phys. Res.

    Acoustic and optical variations during rapid downward motion episodes in the deep north-western Mediterranean Sea

    Get PDF
    An Acoustic Doppler Current Profiler (ADCP) was moored at the deep-sea site of the ANTARES neutrino telescope near Toulon, France, thus providing a unique opportunity to compare high-resolution acoustic and optical observations between 70 and 170 m above the sea bed at 2475 m. The ADCP measured downward vertical currents of magnitudes up to 0.03 m s-1 in late winter and early spring 2006. In the same period, observations were made of enhanced levels of acoustic reflection, interpreted as suspended particles including zooplankton, by a factor of about 10 and of horizontal currents reaching 0.35 m s-1. These observations coincided with high light levels detected by the telescope, interpreted as increased bioluminescence. During winter 2006 deep dense-water formation occurred in the Ligurian subbasin, thus providing a possible explanation for these observations. However, the 10-20 days quasi-periodic episodes of high levels of acoustic reflection, light and large vertical currents continuing into the summer are not direct evidence of this process. It is hypothesized that the main process allowing for suspended material to be moved vertically later in the year is local advection, linked with topographic boundary current instabilities along the rim of the 'Northern Current'.Comment: 30 pages, 7 figure

    The ANTARES Telescope Neutrino Alert System

    Get PDF
    The ANTARES telescope has the capability to detect neutrinos produced in astrophysical transient sources. Potential sources include gamma-ray bursts, core collapse supernovae, and flaring active galactic nuclei. To enhance the sensitivity of ANTARES to such sources, a new detection method based on coincident observations of neutrinos and optical signals has been developed. A fast online muon track reconstruction is used to trigger a network of small automatic optical telescopes. Such alerts are generated for special events, such as two or more neutrinos, coincident in time and direction, or single neutrinos of very high energy.Comment: 17 pages, 9 figures submitted to Astroparticle Physic

    An improved method for measuring muon energy using the truncated mean of dE/dx

    Full text link
    The measurement of muon energy is critical for many analyses in large Cherenkov detectors, particularly those that involve separating extraterrestrial neutrinos from the atmospheric neutrino background. Muon energy has traditionally been determined by measuring the specific energy loss (dE/dx) along the muon's path and relating the dE/dx to the muon energy. Because high-energy muons (E_mu > 1 TeV) lose energy randomly, the spread in dE/dx values is quite large, leading to a typical energy resolution of 0.29 in log10(E_mu) for a muon observed over a 1 km path length in the IceCube detector. In this paper, we present an improved method that uses a truncated mean and other techniques to determine the muon energy. The muon track is divided into separate segments with individual dE/dx values. The elimination of segments with the highest dE/dx results in an overall dE/dx that is more closely correlated to the muon energy. This method results in an energy resolution of 0.22 in log10(E_mu), which gives a 26% improvement. This technique is applicable to any large water or ice detector and potentially to large scintillator or liquid argon detectors.Comment: 12 pages, 16 figure

    Discrimination against HIV-Infected People and the Spread of HIV: Some Evidence from France

    Get PDF
    BACKGROUND: Many people living with HIV/AIDS (PLWHA) suffer from stigma and discrimination. There is an ongoing debate, however, about whether stigma, fear and discrimination actually fuel the persisting spread of HIV, or slow it down by reducing contacts between the whole population and high-risk minorities. To contribute to this debate, we analysed the relationship between perceived discrimination and unsafe sex in a large sample of French PLWHAs. METHODOLOGY/PRINCIPAL FINDINGS: In 2003, we conducted a national cross-sectional survey among a random sample of HIV-infected patients. The analysis was restricted to sexually active respondents (N = 2,136). Unsafe sex was defined as sexual intercourse without a condom with a seronegative/unknown serostatus partner during the prior 12 months. Separate analyses were performed for each transmission group (injecting drug use (IDU), homosexual contact, heterosexual contact). Overall, 24% of respondents reported experiences of discrimination in their close social environment (relatives, friends and colleagues) and 18% reported unsafe sex during the previous 12 months. Both prevalences were higher in the IDU group (32% for perceived discrimination, 23% for unsafe sex). In multivariate analyses, experience of discrimination in the close social environment was associated with an increase in unsafe sex for both PLWHAs infected through IDU and heterosexual contact (OR = 1.65 and 1.80 respectively). CONCLUSIONS: Our study clearly confirms a relationship between discrimination and unsafe sex among PLWHAs infected through either IDU or heterosexual contact. This relationship was especially strong in the heterosexual group that has become the main vector of HIV transmission in France, and who is the more likely of sexual mixing with the general population. These results seriously question the hypothesis that HIV-stigma has no effect or could even reduce the infection spread of HIV
    • 

    corecore