623 research outputs found

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Quantum Vacuum Experiments Using High Intensity Lasers

    Full text link
    The quantum vacuum constitutes a fascinating medium of study, in particular since near-future laser facilities will be able to probe the nonlinear nature of this vacuum. There has been a large number of proposed tests of the low-energy, high intensity regime of quantum electrodynamics (QED) where the nonlinear aspects of the electromagnetic vacuum comes into play, and we will here give a short description of some of these. Such studies can shed light, not only on the validity of QED, but also on certain aspects of nonperturbative effects, and thus also give insights for quantum field theories in general.Comment: 9 pages, 8 figur

    High-performance shape-engineerable thermoelectric painting

    Get PDF
    Output power of thermoelectric generators depends on device engineering minimizing heat loss as well as inherent material properties. However, the device engineering has been largely neglected due to the limited flat or angular shape of devices. Considering that the surface of most heat sources where these planar devices are attached is curved, a considerable amount of heat loss is inevitable. To address this issue, here, we present the shape-engineerable thermoelectric painting, geometrically compatible to surfaces of any shape. We prepared Bi2Te3-based inorganic paints using the molecular Sb2Te3 chalcogenidometalate as a sintering aid for thermoelectric particles, with ZT values of 0.67 for n-type and 1.21 for p-type painted materials that compete the bulk values. Devices directly brush-painted onto curved surfaces produced the high output power of 4.0 mW cm(-2). This approach paves the way to designing materials and devices that can be easily transferred to other applications.ope

    High temperature thermoreflectance imaging and transient Harman characterization of thermoelectric energy conversion devices

    Get PDF
    Advances in thin film growth technology have enabled the selective engineering of material properties to improve the thermoelectric figure of merit and thus the efficiency of energy conversion devices. Precise characterization at the operational temperature of novel thermoelectric materials is crucial to evaluate their performance and optimize their behavior. However, measurements on thin film devices are subject to complications from the growth substrate, non-ideal contacts, and other thermal and electrical parasitic effects. In this manuscript, we determine the cross-plane thermoelectric material properties in a single measurement of a 25 mu m InGaAs thin film with embedded ErAs (0.2%) nanoparticles using the bipolar transient Harman method in conjunction with thermoreflectance thermal imaging at temperatures up to 550K. This approach eliminates discrepancies and potential device degradation from the multiple measurements necessary to obtain individual material parameters. In addition, we present a strategy for optimizing device geometry to mitigate the effect of both electrical and thermal parasitics during the measurement. Finite element method simulations are utilized to analyze non-uniform current and temperature distributions over the device area as well as the three dimensional current path for accurate extraction of material properties from the thermal images. Results are compared with independent in-plane and 3 omega measurements of thermoelectric material properties for the same material composition and are found to match reasonably well; the obtained figure of merit matches within 15% at room and elevated temperatures. (C) 2014 AIP Publishing LLC

    Identification and Filtering of Uncharacteristic Noise in the CMS Hadron Calorimeter

    Get PDF
    VertaisarvioitupeerReviewe

    Performance of CMS hadron calorimeter timing and synchronization using test beam, cosmic ray, and LHC beam data

    Get PDF
    This paper discusses the design and performance of the time measurement technique and of the synchronization systems of the CMS hadron calorimeter. Time measurement performance results are presented from test beam data taken in the years 2004 and 2006. For hadronic showers of energy greater than 100 GeV, the timing resolution is measured to be about 1.2 ns. Time synchronization and out-of-time background rejection results are presented from the Cosmic Run At Four Tesla and LHC beam runs taken in the Autumn of 2008. The inter-channel synchronization is measured to be within ±2 ns

    One-dimensional steady-state structures at relativistic interaction of laser radiation with overdense plasma for finite electron temperature

    Full text link
    One-dimensional steady-state plasma-field structures in overdense plasma are studied assuming that the electron temperature is uniform over plasma bulk and the ions are stationary. It is shown that there may exist solutions for electron distributions with cavitation regions in plasma under the action of ponderomotive forceComment: 6 pages, 4 figure

    Characterization of focal field formed by a large numerical aperture paraboloidal mirror and generation of ultra-high intensity (10 22 W/cm 2 )

    Full text link
    We describe a method to measure the aberrations of a high numerical aperture off-axis paraboloid and correct for the aberrations using adaptive optics. It is then shown that the characterized aberrations can be used to accurately calculate the electromagnetic field at the focus using the Stratton–Chu vector diffraction theory. Using this methodology, an intensity of 7×10 21 W/cm 2 was demonstrated by focusing a 45-TW laser beam with an f /0.6, 90 ∘ off-axis paraboloid after correcting the aberrations of the paraboloid and the low-energy reference beam. The intensity can be further increased to 1×10 22 W/cm 2 by including in the correction algorithm the wavefront difference between the reference beam and the high-energy beam.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/47049/1/340_2005_Article_1803.pd
    corecore