30 research outputs found

    Electroweak measurements in electron–positron collisions at w-boson-pair energies at lep

    Get PDF
    Contains fulltext : 121524.pdf (preprint version ) (Open Access

    Search for Charged Higgs bosons: Combined Results Using LEP Data

    Get PDF
    The four LEP collaborations, ALEPH, DELPHI, L3 and OPAL, have searched for pair-produced charged Higgs bosons in the framework of Two Higgs Doublet Models (2HDMs). The data of the four experiments are statistically combined. The results are interpreted within the 2HDM for Type I and Type II benchmark scenarios. No statistically significant excess has been observed when compared to the Standard Model background prediction, and the combined LEP data exclude large regions of the model parameter space. Charged Higgs bosons with mass below 80 GeV/c^2 (Type II scenario) or 72.5 GeV/c^2 (Type I scenario, for pseudo-scalar masses above 12 GeV/c^2) are excluded at the 95% confidence level

    Precision measurement of the ratio of the Lambda(0)(b) to (B)over-bar(0) lifetimes

    No full text
    The LHCb measurement of the lifetime ratio of the Lambda(0)(b) baryon to the (B) over bar (0) meson is updated using data corresponding to an integrated luminosity of 3.0 fb(-1) collected using 7 and 8 TeV centre-of-mass energy pp collisions at the LHC. The decay modes used are Lambda(0)(b) -> J/psi pK(-) and (B) over bar (0) -> J/psi pi K-+(-), where the pi K-+(-) mass is consistent with that of the (K) over bar*(0)(892) meson. The lifetime ratio is determined with unprecedented precision to be 0.974 +/- 0.006 +/- 0.004, where the first uncertainty is statistical and the second systematic. This result is in agreement with original theoretical predictions based on the heavy quark expansion. Using the current world average of the (B) over bar (0) lifetime, the Lambda(0)(b) lifetime is found to be 1.479 +/- 0.009 +/- 0.010 ps. (C) 2014 The Authors. Published by Elsevier B.V

    LHCb detector performance

    No full text
    The LHCb detector is a forward spectrometer at the Large Hadron Collider (LHC) at CERN. The experiment is designed for precision measurements of CP violation and rare decays of beauty and charm hadrons. In this paper the performance of the various LHCb sub-detectors and the trigger system are described, using data taken from 2010 to 2012. It is shown that the design criteria of the experiment have been met. The excellent performance of the detector has allowed the LHCb collaboration to publish a wide range of physics results, demonstrating LHCb's unique role, both as a heavy flavour experiment and as a general purpose detector in the forward region

    Evidence for the decay X(3872) -> psi(2S)gamma

    No full text
    Evidence for the decay mode X(3872) -> psi(2S)gamma in B+ -> X(3872)K+ decays is found with a significance of 4.4 standard deviations. The analysis is based on a data sample of proton proton collisions, corresponding to an integrated luminosity of 3 fb(-1), collected with the LHCb detector, at centre-of-mass energies of 7 and 8 TeV. The ratio of the branching fraction of the X(3872) -> psi(2S)gamma decay to that of the X(3872) -> J/psi gamma decay is measured to be B(X(3872) -> psi(2S)gamma)/B(X(3872) -> J/psi gamma) = 2.46 +/- 0.64 +/- 0.29, where the first uncertainty is statistical and the second is systematic. The measured value does not support a pure D (D) over bar* molecular interpretation of the X(3872) state. (C) 2014 CERN for the benefit of the LHCb Collaboration. Published by Elsevier B.V

    First measurement of time-dependent CP violation in Bs0K+K B_s^0\to K^+K^- decays

    No full text
    Direct and mixing-induced CP-violating asymmetries in B-s(0) -> K+K- decays are measured for the first time using a data sample of p p collisions, corresponding to an integrated luminosity of 1.0 fb(-1), collected with the LHCb detector at a centre-of-mass energy of 7 TeV. The results are C-KK = 0.14 +/- 0.11 +/- 0.03 and S-KK = 0.30 +/- 0.12 +/- 0.04, where the first uncertainties are statistical and the second systematic. The corresponding quantities are also determined for B-0 -> pi(+)pi(-) decays to be C-pi pi = -0.38 +/- 0.15 +/- 0.02 and S-pi pi = -0.71 +/- 0.13 +/- 0.02, in good agreement with existing measurements

    Measurement of CP violation and constraints on the CKM angle gamma in B-+/- -> DK +/- with D -> K-s(0)pi(+)pi(-) decays

    No full text
    A model-dependent amplitude analysis of B-+/- -> DK +/- with D -> K-s(0)pi(+)pi(-) decays is performed using proton proton collision data, corresponding to an integrated luminosity of 1 fb(-1), recorded by LHCb at a centre-of-mass energy of 7 TeV in 2011. Values of the CP violation observables x +/- and y +/-, which are sensitive to the CKM angle gamma, are measured to be x- = +0.027 +/- 0.0441(-0.008)(+0.010) +/- 0.001, y- = +0.013 +/- 0.0481(-0.007)(+0.009) +/- 0.003, x+ = -0.084 +/- 0.045 +/- 0.009 +/- 0.005, y+ = -0.032 +/- 0.048(-0.009)(+0.010) +/- 0.008, where the first uncertainty is statistical, the second systematic and the third arises from the uncertainty of the D -> K-S(0)pi(+)pi(-) amplitude model. The value of gamma is determined to be (84(-42)(+49))degrees including all sources of uncertainty. Neutral D meson mixing is found to have negligible effect. (C) 2014 The Authors. Published by Elsevier B.V

    Precision luminosity measurements at LHCb

    No full text
    Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy root s. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for root s = 2.76, 7 and 8TeV (proton-proton collisions) and for root s(NN) = 5TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at root s = 8TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider

    Determination of gamma and-2 beta(s) from charmless two-body decays of beauty mesons

    No full text
    Using the latest LHCb measurements of time-dependent CP violation in the B-s(0) -> K+K- decay, a U-spin relation between the decay amplitudes of B-s(0) -> K+K- and B-0 -> p(+)p(-) decay processes allows constraints to be placed on the angle gamma of the unitarity triangle and on the B-s(0) mixing phase -2 beta(s). Results from an extended approach, which uses additional inputs on B-0 -> pi(0)pi(0) and B+ -> pi(+)pi(0) decays from other experiments and exploits isospin symmetry, are also presented. The dependence of the results on the maximum allowed amount of U-spin breaking is studied. At 68% probability, the value gamma =( 63.5(-6.7)(+7.2))degrees modulo 180 degrees is determined. In an alternative analysis, the value -2 beta(s)= - 0.12(-0.16)(+ 0.14) rad is found. In both measurements, the uncertainties due to U-spin breaking effects up to 50% are included. (C) 2014 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/3.0/)

    Effective lifetime measurements in the B-s(0) -> K+K-, B-0 -> K+pi(-) and B-s(0) -> pi K-+(-) decays

    No full text
    Measurements of the effective lifetimes in the B-s(0) -> K+K-, B-0 -> K+pi(-) and B-s(0) -> pi K-+(-) decays are presented using 1.0 fb(-1)of pp collision data collected at a centre-of-mass energy of 7 TeV by the LHCb experiment. The analysis uses a data-driven approach to correct for the decay time acceptance. The measured effective lifetimes are tau(Bs0 -> K+K-) = 1.407 +/- 0.016 (stat) +/- 0.007 (syst) ps, tau(Bs0 -> K+pi-) = 1.524 +/- 0.011 (stat) +/- 0.004 (syst) ps, tau(Bs0 ->pi+K-) = 1.60 +/- 0.06 (stat) +/- 0.01 (syst) ps. This is the most precise determination to date of the effective lifetime in the B-s(0) -> K+K- decay and provides constraints on contributions from physics beyond the Standard Model to the B-s(0) mixing phase and the width difference Delta Gamma(s). (C) 2014 The Authors. Published by Elsevier B.V
    corecore