5,832 research outputs found
First study of radiation hardness of lead tungstate crystals at low temperatures
The electromagnetic calorimeter of PANDA at the FAIR facility will rely on an
operation of lead tungstate (PWO) scintillation crystals at temperatures near
-25 deg.C to provide sufficient resolution for photons in the energy range from
8 GeV down to 10 MeV. Radiation hardness of PWO crystals was studied at the
IHEP (Protvino) irradiation facility in the temperature range from room
temperature down to -25 deg.C. These studies have indicated a significantly
different behaviour in the time evolution of the damaging processes well below
room temperature. Different signal loss levels at the same dose rate, but at
different temperatures were observed. The effect of a deep suppression of the
crystal recovery process at temperatures below
0 deg.C has been seen.Comment: 10 pages 7 figure
Technical Design Report for the PANDA Solenoid and Dipole Spectrometer Magnets
This document is the Technical Design Report covering the two large
spectrometer magnets of the PANDA detector set-up. It shows the conceptual
design of the magnets and their anticipated performance. It precedes the tender
and procurement of the magnets and, hence, is subject to possible modifications
arising during this process.Comment: 10 pages, 14MB, accepted by FAIR STI in May 2009, editors: Inti
Lehmann (chair), Andrea Bersani, Yuri Lobanov, Jost Luehning, Jerzy Smyrski,
Technical Coordiantor: Lars Schmitt, Bernd Lewandowski (deputy),
Spokespersons: Ulrich Wiedner, Paola Gianotti (deputy
Expected Accuracy in a Measurement of the CKM Angle Using a Dalitz Plot Analysis of \boldmath B^0 \to \rho \pi Decays in the BTeV Project
A precise measurement of the angle in the CKM triangle is very
important for a complete test of Standard Model. A theoretically clean method
to extract is provided by B decays. Monte Carlo
simulations to obtain the BTeV reconstruction efficiency and to estimate the
signal to background ratio for these decays were performed. Finally the
time-dependent Dalitz plot analysis, using the isospin amplitude formalism for
tree and penguin contributions, was carried out. It was shown that in one year
of data taking BTeV could achieve an accuracy on better than
5.Comment: 26 pages, 11 figures. To be submitted to Phys.Atom.Nuc
Feasibility studies of time-like proton electromagnetic form factors at PANDA at FAIR
Simulation results for future measurements of electromagnetic proton form
factors at \PANDA (FAIR) within the PandaRoot software framework are reported.
The statistical precision with which the proton form factors can be determined
is estimated. The signal channel is studied on the basis
of two different but consistent procedures. The suppression of the main
background channel, , is studied.
Furthermore, the background versus signal efficiency, statistical and
systematical uncertainties on the extracted proton form factors are evaluated
using two different procedures. The results are consistent with those of a
previous simulation study using an older, simplified framework. However, a
slightly better precision is achieved in the PandaRoot study in a large range
of momentum transfer, assuming the nominal beam conditions and detector
performance
Precise measurement of the W-boson mass with the CDF II detector
We have measured the W-boson mass MW using data corresponding to 2.2/fb of
integrated luminosity collected in proton-antiproton collisions at 1.96 TeV
with the CDF II detector at the Fermilab Tevatron collider. Samples consisting
of 470126 W->enu candidates and 624708 W->munu candidates yield the measurement
MW = 80387 +- 12 (stat) +- 15 (syst) = 80387 +- 19 MeV. This is the most
precise measurement of the W-boson mass to date and significantly exceeds the
precision of all previous measurements combined
- …