299 research outputs found

    Solid state high power RF system for superconducting cavities

    Get PDF
    Solid State High Power RF System is proposed for XFEL and ILC. It includes individual RF power supply for each SC cavity and common control system. Each RF power supply includes Solid State Generator, circulator and Q-tuner. Triggering, synchronization, output power and phase of each Solid State Generator are controlled from the common control system through fiber-optic lines. Main parameters of Solid State Generator are: frequency 1.3 GHz, peak power 128 kW, pulse length 1.4 msec, repetition rate 10 Hz, average power 1.8 kW, CW power 2.5 kW. Advantages of Solid State High Power RF System are: simple triggering, synchronization, output power and phase adjustment for all cavities separately, operation both in pulse and in CW modes, unlimited lifetime, no high voltage, no oil-tank, compactness.Предложен твердотельный вариант СВЧ-системы питания для проектов XFEL и ILC, включающий индивидуальный источник питания для каждого СП-резонатора и общую систему управления. Каждый источник питания содержит твердотельный генератор, циркулятор и систему подстройки добротности. Переключение, синхронизация, выходная мощность и фаза каждого твердотельного генератора контролируются общей системой управления по средствам оптоволоконного кабеля. Основные параметры твердотельного генератора: частота 1,3 ГГц, пиковая мощность 128 кВт, длина импульса 1,4 мс, частота повторения 10 Гц, средняя мощность 1,8 кВт, непрерывная мощность 2,5 кВт. Преимущества твердотельной СВЧ-системы питания: простые переключение и синхронизация, раздельная подстройка выходной мощности и фазы для каждого резонатора, возможность работы как в импульсном, так и в непрерывном режиме, неограниченный срок службы, отсутствие высокого напряжения и масляного бака, компактность.Запропоновано твердотільний варіант НВЧ-системи живлення для проектів XFEL і ІLC, що включає індивідуальне джерело живлення для кожного НП-резонатора і загальну систему керування. Кожне джерело живлення містить твердотільний генератор, циркулятор і систему підстроювання добротності. Перемикання, синхронізація, вихідна потужність і фаза кожного твердотільного генератора контролюються загальною системою керування по засобах оптоволоконного кабеля. Основні параметри твердотільного генератора: частота 1,3 ГГц, пікова потужність 128 кВт, довжина імпульсу 1,4 мс, частота повторення 10 Гц, середня потужність 1,8 кВт, безперервна потужність 2,5 кВт. Переваги твердотільної НВЧ-системи живлення: прості перемикання і синхронізація, роздільне підстроювання вихідної потужності і фази для кожного резонатора, можливість роботи як в імпульсному, так і у безперервному режимі, необмежений термін служби, відсутність високої напруги і масляного бака, компактність

    Model-independent search for CP violation in D0→K−K+π−π+ and D0→π−π+π+π− decays

    Get PDF
    A search for CP violation in the phase-space structures of D0 and View the MathML source decays to the final states K−K+π−π+ and π−π+π+π− is presented. The search is carried out with a data set corresponding to an integrated luminosity of 1.0 fb−1 collected in 2011 by the LHCb experiment in pp collisions at a centre-of-mass energy of 7 TeV. For the K−K+π−π+ final state, the four-body phase space is divided into 32 bins, each bin with approximately 1800 decays. The p-value under the hypothesis of no CP violation is 9.1%, and in no bin is a CP asymmetry greater than 6.5% observed. The phase space of the π−π+π+π− final state is partitioned into 128 bins, each bin with approximately 2500 decays. The p-value under the hypothesis of no CP violation is 41%, and in no bin is a CP asymmetry greater than 5.5% observed. All results are consistent with the hypothesis of no CP violation at the current sensitivity

    Search for the lepton-flavor-violating decays Bs0→e±μ∓ and B0→e±μ∓

    Get PDF
    A search for the lepton-flavor-violating decays Bs0→e±μ∓ and B0→e±μ∓ is performed with a data sample, corresponding to an integrated luminosity of 1.0  fb-1 of pp collisions at √s=7  TeV, collected by the LHCb experiment. The observed number of Bs0→e±μ∓ and B0→e±μ∓ candidates is consistent with background expectations. Upper limits on the branching fractions of both decays are determined to be B(Bs0→e±μ∓)101  TeV/c2 and MLQ(B0→e±μ∓)>126  TeV/c2 at 95% C.L., and are a factor of 2 higher than the previous bounds

    Measurement of the Bs0J/ψKS0B_s^0\to J/\psi K_S^0 branching fraction

    Get PDF
    The Bs0J/ψKS0B_s^0\to J/\psi K_S^0 branching fraction is measured in a data sample corresponding to 0.41fb1fb^{-1} of integrated luminosity collected with the LHCb detector at the LHC. This channel is sensitive to the penguin contributions affecting the sin2β\beta measurement from B0J/ψKS0B^0\to J/\psi K_S^0 The time-integrated branching fraction is measured to be BF(Bs0J/ψKS0)=(1.83±0.28)×105BF(B_s^0\to J/\psi K_S^0)=(1.83\pm0.28)\times10^{-5}. This is the most precise measurement to date

    Branching fraction and CP asymmetry of the decays B+→K0Sπ+ and B+→K0SK+

    Get PDF
    An analysis of B+ → K0 Sπ+ and B+ → K0 S K+ decays is performed with the LHCb experiment. The pp collision data used correspond to integrated luminosities of 1 fb−1 and 2 fb−1 collected at centre-ofmass energies of √ s = 7 TeV and √ s = 8 TeV, respectively. The ratio of branching fractions and the direct CP asymmetries are measured to be B(B+ → K0 S K+ )/B(B+ → K0 Sπ+ ) = 0.064 ± 0.009 (stat.) ± 0.004 (syst.), ACP(B+ → K0 Sπ+ ) = −0.022 ± 0.025 (stat.) ± 0.010 (syst.) and ACP(B+ → K0 S K+ ) = −0.21 ± 0.14 (stat.) ± 0.01 (syst.). The data sample taken at √ s = 7 TeV is used to search for B+ c → K0 S K+ decays and results in the upper limit ( fc · B(B+ c → K0 S K+ ))/( fu · B(B+ → K0 Sπ+ )) < 5.8 × 10−2 at 90% confidence level, where fc and fu denote the hadronisation fractions of a ¯b quark into a B+ c or a B+ meson, respectively

    Measurement of the CP-violating phase \phi s in Bs->J/\psi\pi+\pi- decays

    Get PDF
    Measurement of the mixing-induced CP-violating phase phi_s in Bs decays is of prime importance in probing new physics. Here 7421 +/- 105 signal events from the dominantly CP-odd final state J/\psi pi+ pi- are selected in 1/fb of pp collision data collected at sqrt{s} = 7 TeV with the LHCb detector. A time-dependent fit to the data yields a value of phi_s=-0.019^{+0.173+0.004}_{-0.174-0.003} rad, consistent with the Standard Model expectation. No evidence of direct CP violation is found.Comment: 15 pages, 10 figures; minor revisions on May 23, 201

    Absolute luminosity measurements with the LHCb detector at the LHC

    Get PDF
    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.Comment: 48 pages, 19 figures. Results unchanged, improved clarity of Table 6, 9 and 10 and corresponding explanation in the tex

    Measurement of the ratio of branching fractions BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma) and the direct CP asymmetry in B0 -> K*0 gamma

    Get PDF
    The ratio of branching fractions of the radiative B decays B0 -> K*0 gamma and Bs0 phi gamma has been measured using an integrated luminosity of 1.0 fb-1 of pp collision data collected by the LHCb experiment at a centre-of-mass energy of sqrt(s)=7 TeV. The value obtained is BR(B0 -> K*0 gamma)/BR(Bs0 -> phi gamma) = 1.23 +/- 0.06(stat.) +/- 0.04(syst.) +/- 0.10(fs/fd), where the first uncertainty is statistical, the second is the experimental systematic uncertainty and the third is associated with the ratio of fragmentation fractions fs/fd. Using the world average value for BR(B0 -> K*0 gamma), the branching fraction BR(Bs0 -> phi gamma) is measured to be (3.5 +/- 0.4) x 10^{-5}. The direct CP asymmetry in B0 -> K*0 gamma decays has also been measured with the same data and found to be A(CP)(B0 -> K*0 gamma) = (0.8 +/- 1.7(stat.) +/- 0.9(syst.))%. Both measurements are the most precise to date and are in agreement with the previous experimental results and theoretical expectations.Comment: 21 pages, 3 figues, 4 table

    Absolute luminosity measurements with the LHCb detector at the LHC

    Get PDF
    Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.Comment: 48 pages, 19 figures. Results unchanged, improved clarity of Table 6, 9 and 10 and corresponding explanation in the tex
    corecore