13 research outputs found

    Thermal neutron background at Laboratorio Subterráneo de Canfranc (LSC)

    Get PDF
    The thermal neutron background at Laboratorio Subterráneo de Canfranc (LSC) has been determined using several He proportional counter detectors. Bare and Cd shielded counters were used in a series of long measurements. Pulse shape discrimination techniques were applied to discriminate between neutron and gamma signals as well as other intrinsic contributions. Montecarlo simulations allowed us to estimate the sensitivity of the detectors and calculate values for the background flux of thermal neutrons inside Hall-A of LSC. The obtained value is (3.5±0.8)×10 n/cms, and is within an order of magnitude compared to similar facilities.This work was supported partially by the Spanish Ministerio de Ciencia e Innovación and its Plan Nacional de I+D+i de Física de Partículas projects: FPA2016-76765-P and FPA2018-096717-B-C21. The authors want to acknowledge the help provided by the staff at LSC in the preparation and support for this work

    Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments

    Full text link
    One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C6_{6}D6_{6} liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from 197^{197}Au(nn,γ\gamma), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements

    Status report of the n_TOF facility after the 2nd CERN long shutdown period

    No full text
    Abstract During the second long shutdown period of the CERN accelerator complex (LS2, 2019-2021), several upgrade activities took place at the n_TOF facility. The most important have been the replacement of the spallation target with a next generation nitrogen-cooled lead target. Additionally, a new experimental area, at a very short distance from the target assembly (the NEAR Station) was established. In this paper, the core commissioning actions of the new installations are described. The improvement in the n_TOF infrastructure was accompanied by several detector development projects. All these upgrade actions are discussed, focusing mostly on the future perspectives of the n_TOF facility. Furthermore, some indicative current and future measurements are briefly reported

    Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments

    No full text
    One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n_TOF facility, the detectors of choice are the C6D6 liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n_TOF 20 m flight path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from 197Au(n, γ), including the saturated 4.9 eV resonance which is an important component of normalization for neutron cross section measurements.One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n_TOF facility, the detectors of choice are the C6_{6}D6_{6} liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from 197^{197}Au(nn,γ\gamma), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements

    Comprehensive analysis and insights gained from long-term experience of the Spanish DILI Registry

    Get PDF
    Altres ajuts: Fondo Europeo de Desarrollo Regional (FEDER); Agencia Española del Medicamento; Consejería de Salud de Andalucía.Background & Aims: Prospective drug-induced liver injury (DILI) registries are important sources of information on idiosyncratic DILI. We aimed to present a comprehensive analysis of 843 patients with DILI enrolled into the Spanish DILI Registry over a 20-year time period. Methods: Cases were identified, diagnosed and followed prospectively. Clinical features, drug information and outcome data were collected. Results: A total of 843 patients, with a mean age of 54 years (48% females), were enrolled up to 2018. Hepatocellular injury was associated with younger age (adjusted odds ratio [aOR] per year 0.983; 95% CI 0.974-0.991) and lower platelet count (aOR per unit 0.996; 95% CI 0.994-0.998). Anti-infectives were the most common causative drug class (40%). Liver-related mortality was more frequent in patients with hepatocellular damage aged ≥65 years (p = 0.0083) and in patients with underlying liver disease (p = 0.0221). Independent predictors of liver-related death/transplantation included nR-based hepatocellular injury, female sex, higher onset aspartate aminotransferase (AST) and bilirubin values. nR-based hepatocellular injury was not associated with 6-month overall mortality, for which comorbidity burden played a more important role. The prognostic capacity of Hy's law varied between causative agents. Empirical therapy (corticosteroids, ursodeoxycholic acid and MARS) was prescribed to 20% of patients. Drug-induced autoimmune hepatitis patients (26 cases) were mainly females (62%) with hepatocellular damage (92%), who more frequently received immunosuppressive therapy (58%). Conclusions: AST elevation at onset is a strong predictor of poor outcome and should be routinely assessed in DILI evaluation. Mortality is higher in older patients with hepatocellular damage and patients with underlying hepatic conditions. The Spanish DILI Registry is a valuable tool in the identification of causative drugs, clinical signatures and prognostic risk factors in DILI and can aid physicians in DILI characterisation and management. Lay summary: Clinical information on drug-induced liver injury (DILI) collected from enrolled patients in the Spanish DILI Registry can guide physicians in the decision-making process. We have found that older patients with hepatocellular type liver injury and patients with additional liver conditions are at a higher risk of mortality. The type of liver injury, patient sex and analytical values of aspartate aminotransferase and total bilirubin can also help predict clinical outcomes

    Safety of primary anastomosis following emergency left sided colorectal resection: an international, multi-centre prospective audit.

    Get PDF
    This is the peer reviewed version of the following article: group, T. E. S. o. C. c. (2018). "Safety of primary anastomosis following emergency left sided colorectal resection: an international, multi-centre prospective audit." Colorectal Disease 20(S6): 47-57., which has been published in final form at https://doi.org/10.1111/codi.1437. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived VersionsINTRODUCTION: Some evidence suggests that primary anastomosis following left sided colorectal resection in the emergency setting may be safe in selected patients, and confer favourable outcomes to permanent enterostomy. The aim of this study was to compare the major postoperative complication rate in patients undergoing end stoma vs primary anastomosis following emergency left sided colorectal resection. METHODS: A pre-planned analysis of the European Society of Coloproctology 2017 audit. Adult patients (> 16 years) who underwent emergency (unplanned, within 24 h of hospital admission) left sided colonic or rectal resection were included. The primary endpoint was the 30-day major complication rate (Clavien-Dindo grade 3 to 5). RESULTS: From 591 patients, 455 (77%) received an end stoma, 103 a primary anastomosis (17%) and 33 primary anastomosis with defunctioning stoma (6%). In multivariable models, anastomosis was associated with a similar major complication rate to end stoma (adjusted odds ratio for end stoma 1.52, 95%CI 0.83-2.79, P = 0.173). Although a defunctioning stoma was not associated with reduced anastomotic leak (12% defunctioned [4/33] vs 13% not defunctioned [13/97], adjusted odds ratio 2.19, 95%CI 0.43-11.02, P = 0.343), it was associated with less severe complications (75% [3/4] with defunctioning stoma, 86.7% anastomosis only [13/15]), a lower mortality rate (0% [0/4] vs 20% [3/15]), and fewer reoperations (50% [2/4] vs 73% [11/15]) when a leak did occur. CONCLUSIONS: Primary anastomosis in selected patients appears safe after left sided emergency colorectal resection. A defunctioning stoma might mitigate against risk of subsequent complications

    The impact of conversion on the risk of major complication following laparoscopic colonic surgery: an international, multicentre prospective audit.

    Get PDF
    This is the peer reviewed version of the following article: The and E. S. o. C. c. groups (2018). "The impact of conversion on the risk of major complication following laparoscopic colonic surgery: an international, multicentre prospective audit." Colorectal Disease 20(S6): 69-89., which has been published in final form at https://doi.org/10.1111/codi.14371. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versions.BACKGROUND: Laparoscopy has now been implemented as a standard of care for elective colonic resection around the world. During the adoption period, studies showed that conversion may be detrimental to patients, with poorer outcomes than both laparoscopic completed or planned open surgery. The primary aim of this study was to determine whether laparoscopic conversion was associated with a higher major complication rate than planned open surgery in contemporary, international practice. METHODS: Combined analysis of the European Society of Coloproctology 2017 and 2015 audits. Patients were included if they underwent elective resection of a colonic segment from the caecum to the rectosigmoid junction with primary anastomosis. The primary outcome measure was the 30-day major complication rate, defined as Clavien-Dindo grade III-V. RESULTS: Of 3980 patients, 64% (2561/3980) underwent laparoscopic surgery and a laparoscopic conversion rate of 14% (359/2561). The major complication rate was highest after open surgery (laparoscopic 7.4%, converted 9.7%, open 11.6%, P < 0.001). After case mix adjustment in a multilevel model, only planned open (and not laparoscopic converted) surgery was associated with increased major complications in comparison to laparoscopic surgery (OR 1.64, 1.27-2.11, P < 0.001). CONCLUSIONS: Appropriate laparoscopic conversion should not be considered a treatment failure in modern practice. Conversion does not appear to place patients at increased risk of complications vs planned open surgery, supporting broadening of selection criteria for attempted laparoscopy in elective colonic resection
    corecore