134 research outputs found

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Health and health belief factors associated with screening and help-seeking behaviours for breast cancer symptoms: a systematic review and meta-analysis of the European evidence

    Get PDF
    Purpose: The aim of this systematic review was to identify health or health belief factors associated with mammography attendance or with self-initiated medical help-seeking for breast cancer symptoms among women in Europe. Methods: Five databases were searched for articles published between 2005 and 2018. Meta-analyses were conducted for 13 factors related to screening attendance and two factors associated with help-seeking behaviour. Where there were too few studies to include in the meta-analysis a narrative synthesis was undertaken. Results: Sixty-five studies were included. Never having had cervical screening (d=-0.72, p<0.001) and higher perceived barriers to mammography (d=-0.40, p<0.001) were associated with lower levels of screening attendance. Possessing health insurance (d=0.49, p<0.001), greater perceived benefits (d=0.31, p<0.001) and motivation (d=0.36, p=0.003) towards screening, and higher perceived seriousness (d=0.24, p=0.019) and susceptibility (d=0.20, p=0.024) towards breast cancer were associated with a higher level of screening attendance. Presenting with a non-lump symptom was associated with a longer time to presentation (d=0.32, p<0.001). The narrative synthesis revealed that previous benign breast disease was associated with a higher level of screening attendance but with a longer time to presentation. Conclusions: The review identified key similarities in factors associated with screening and help-seeking behaviours which offer scope for combined interventions aimed at women that target both behaviours. Furthermore, the review highlighted that fewer studies have focused on help-seeking behaviour, despite two thirds of breast cancer cases being self-detected. Future research should further examine predictors of help-seeking behaviour including a focus on modifiable factors, such as BMI, and physical activity

    Performance and Operation of the CMS Electromagnetic Calorimeter

    Get PDF
    The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented

    Calibration of the CMS Drift Tube Chambers and Measurement of the Drift Velocity with Cosmic Rays

    Get PDF
    Peer reviewe

    CMS Data Processing Workflows during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    The CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3-4 microns RMS in the barrel and 3-14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance

    Aligning the CMS Muon Chambers with the Muon Alignment System during an Extended Cosmic Ray Run

    Get PDF
    Peer reviewe

    Effectiveness of a multidimensional approach for prevention of ventilator-associated pneumonia in 11 adult intensive care units from 10 cities of Turkey: Findings of the International Nosocomial Infection Control Consortium (INICC)

    Get PDF
    Purpose: To evaluate the impact of the International Nosocomial Infection Control Consortium (INICC) multidimensional approach on the reduction of ventilator-associated pneumonia (VAP) in adult patients hospitalized in 11 intensive care units (ICUs), from 10 hospitals, members of the INICC, in 10 cities of Turkey. Methods: A prospective active before-after surveillance study was conducted to determine the effect of the INICC multidimensional approach in the VAP rate. The study was divided into two phases. In phase 1, active prospective surveillance of VAP was conducted using the definitions of the Centers for Disease Control and Prevention National Health Safety Network, and the INICC methods. In phase 2, we implemented the multidimensional approach for VAP. The INICC multidimensional approach included the following measures: (1) bundle of infection control interventions, (2) education, (3) outcome surveillance, (4) process surveillance, (5) feedback of VAP rates, and (6) performance feedback of infection control practices. We compared the rates of VAP obtained in each phase. A time series analysis was performed to assess the impact of our approach. Results: In phase 1, we recorded 2,376 mechanical ventilator (MV)-days, and in phase 2, after implementing the multidimensional approach, we recorded 28,181 MV-days. The rate of VAP was 31.14 per 1,000 MV-days during phase 1, and 16.82 per 1,000 MV-days during phase 2, amounting to a 46 % VAP rate reduction (RR, 0.54; 95 % CI, 0.42-0.7; P value, 0.0001.) Conclusions: The INICC multidimensional approach was associated with a significant reduction in the VAP rate in these adult ICUs of Turkey. Š 2013 Springer-Verlag Berlin Heidelberg

    Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPDuring autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Alignment of the CMS muon system with cosmic-ray and beam-halo muons

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS muon system has been aligned using cosmic-ray muons collected in 2008 and beam-halo muons from the 2008 LHC circulating beam tests. After alignment, the resolution of the most sensitive coordinate is 80 microns for the relative positions of superlayers in the same barrel chamber and 270 microns for the relative positions of endcap chambers in the same ring structure. The resolution on the position of the central barrel chambers relative to the tracker is comprised between two extreme estimates, 200 and 700 microns, provided by two complementary studies. With minor modifications, the alignment procedures can be applied using muons from LHC collisions, leading to additional significant improvements.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR(Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)
    • …
    corecore