450 research outputs found

    Towards personalised contrast injection: Artificial-intelligence-derived body composition and liver enhancement in computed tomography

    Get PDF
    In contrast-enhanced computed tomography, total body weight adapted contrast injection protocols have proven successful in achieving a homogeneous enhancement of vascular structures and liver parenchyma. However, because solid organs have greater perfusion than adipose tissue, the lean body weight (fat-free mass) rather than the total body weight is theorised to cause even more homogeneous enhancement. We included 102 consecutive patients who underwent a multiphase abdominal computed tomography between March 2016 and October 2019. Patients received contrast media (300 mgI/mL) according to bodyweight categories. Using regions of interest, we measured the Hounsfield unit (HU) increase in liver attenuation from unenhanced to contrast-enhanced computed tomography. Furthermore, subjective image quality was graded using a four-point Likert scale. An artificial intelligence algorithm automatically segmented and determined the body compositions and calculated the percentages of lean body weight. The hepatic enhancements were adjusted for iodine dose and iodine dose per total body weight, as well as percentage lean body weight. The associations between enhancement and total body weight, body mass index, and lean body weight were analysed using linear regression. Patients had a median age of 68 years (IQR: 58–74), a total body weight of 81 kg (IQR: 73 – 90), a body mass index of 26 kg/m2 (SD: ±4.2), and a lean body weight percentage of 50% (IQR: 36 – 55). Mean liver enhancements in the portal venous phase were 61 ± 12 HU (≤ 70 kg), 53 ± 10 HU (70 – 90 kg), and 53 ± 7 HU (≥ 90 kg). The majority (93%) of scans were rated as good or excellent. Regression analysis showed significant correlations between liver enhancement corrected for injected total iodine and total body weight (r = 0.53; p < 0.001) and between liver enhancement corrected for lean body weight and the percentage of lean body weight (r = 0.73; p < 0.001). Most benefits from personalising iodine injection using %LBW additive to total body weight would be achieved in patients under 90 kg. Liver enhancement is more strongly associated with the percentage of lean body weight than with the total body weight or body mass index. The observed variation in liver enhancement might be reduced by a personalised injection based on the artificial-intelligence-determined percentage of lean body weight

    Value of multiparametric magnetic resonance imaging for local staging of invasive urinary bladder tumours.

    Get PDF
    Background: Initial tumour staging in bladder cancer mainly relies on the histo-pathological outcome of the transurethral bladder tumour resection (TURBT) and imaging by means of a CT-scan (CT-intravenous urography; CT-IVU). The reported risk of understaging varies from 24-50%. To further improve the the evaluation of depth of invasion of the bladder tumour the application of magnetic resonance imaging (MRI) may be useful. To substantiate the additional value of this imaging modality the present observational study was designed. Study design: This is a prospective observational study to analyse bladder tumour staging with multiparametric magnetic resonance imaging (mpMRI) in patients with a known bladder tumour, who are planned for radical cystectomy. Study population: Patients with an invasive bladder cancer who are planned for radical cystectomy. Intervention: Patients were accrued during their visit to the outpatient department of urology. They underwent routine cystoscopy, laboratory tests (including serum Creatinin) and CT-IVU investigations and subsequently a mpMRI. Main study parameters/endpoints: To demonstrate the value of mpMRI in the initial staging of bladder tumours using radiological bladder tumour stage (T-stage) based on mpMRI and pathological bladder tumour stage based on ‘whole-mount’ histo-pathology after radical cystectomy. Results: Thirty-seven participants with known bladder tumours underwent mpMRI and subsequent cystectomy. After mpMRI 10 participants were diagnosed with non-muscle-invasive bladder cancer (NMIBC) and 27 participants with muscle-invasive bladder cancer (MIBC). In the ‘whole-mount’ pathology results 12 participants had NMIBC and 25 participants had MIBC. We found a sensitivity and specificity of 0.88 en 0.58 respectively, for the evaluation of MIBC. The positive and negative predictive value were 81% and 70% respectively. The diagnostic accuracy of mpMRI to differentiate between NMIBC and MIBC was 78%. Conclusions: We found a sensitivity of 88% and a specificity of 58% for mpMRI to discriminate NMIBC from MIBC

    Increasing metformin concentrations and its excretion in both rat and porcine ex vivo normothermic kidney perfusion model

    Get PDF
    INTRODUCTION: Metformin can accumulate and cause lactic acidosis in patients with renal insufficiency. Metformin is known to inhibit mitochondria, while renal secretion of the drug by proximal tubules indirectly requires energy. We investigated whether addition of metformin before or during ex vivo isolated normothermic machine perfusion (NMP) of porcine and rat kidneys affects its elimination.RESEARCH DESIGN AND METHODS: First, Lewis rats were pretreated with metformin or saline the day before nephrectomy. Subsequently, NMP of the kidney was performed for 90 min. Metformin was added to the perfusion fluid in one of three different concentrations (none, 30 mg/L or 300 mg/L). Second, metformin was added in increasing doses to the perfusion fluid during 4 hours of NMP of porcine kidneys. Metformin concentration was determined in the perfusion fluid and urine by liquid chromatography-tandem mass spectrometry.RESULTS: Metformin clearance was approximately 4-5 times higher than creatinine clearance in both models, underscoring secretion of the drug. Metformin clearance at the end of NMP in rat kidneys perfused with 30 mg/L was lower than in metformin pretreated rats without the addition of metformin during perfusion (both p≤0.05), but kidneys perfused with 300 mg/L trended toward lower metformin clearance (p=0.06). Creatinine clearance was not different between treatment groups. During NMP of porcine kidneys, metformin clearance peaked at 90 min of NMP (18.2±13.7 mL/min/100 g). Thereafter, metformin clearance declined, while creatinine clearance remained stable. This observation can be explained by saturation of metformin transporters with a Michaelis-Menten constant (95% CI) of 23.0 (10.0 to 52.3) mg/L.CONCLUSIONS: Metformin was secreted during NMP of both rat and porcine kidneys. Excretion of metformin decreased under increasing concentrations of metformin, which might be explained by saturation of metformin transporters rather than a self-inhibitory effect. It remains unknown whether a self-inhibitory effect contributes to metformin accumulation in humans with longer exposure times.</p

    Diagnosing pancreatic neuroendocrine tumors in patients with multiple endocrine neoplasia type 1 in daily practice

    Get PDF
    Background: In multiple endocrine neoplasia type 1 (MEN1), pancreatic neuroendocrine tumors (PanNETs) have a high prevalence and represent the main cause of death. This study aimed to assess the diagnostic accuracy of the currently used conventional pancreatic imaging techniques and the added value of fine needle aspirations (FNAs). Methods: Patients who had at least one imaging study were included from the population-based MEN1 database of the DutchMEN Study Group from 1990 to 2017. Magnetic resonance imaging (MRI), computed tomography (CT), endoscopic ultrasonography (EUS), FNA, and surgical resection specimens were obtained. The first MRI, CT, or EUS was considered as the index test. For a comparison of the diagnostic accuracy of MRI versus CT, patients with their index test taken between 2010 and 2017 were included. The reference standard consisted of surgical histopathology or radiological follow-up. ResultsA total of 413 patients (92.8% of the database) underwent 3,477 imaging studies. The number of imaging studies per patient increased, and a preference for MRI was observed in the last decade. Overall diagnostic accuracy was good with a positive (PPV) and negative predictive value (NPV) of 88.9% (95% confidence interval, 76.0-95.6) and 92.8% (89.4-95.1), respectively, for PanNET in the pancreatic head and 92.0% (85.3-96.0) and 85.3% (80.5-89.1), respectively, in the body/tail. For MRI, PPV and NPV for pancreatic head tumors were 100% (76.1-100) and 87.1% (76.3-93.6) and for CT, 60.0% (22.9-88.4) and 70.4% (51.3-84.3), respectively. For body/tail tumors, PPV and NPV were 91.3% (72.0-98.8) and 87.0% (75.3-93.9), respectively, for MRI and 100% (74.9-100) and 77.8% (54.3-91.5), respectively, for CT. Pathology confirmed a PanNET in 106 out of 110 (96.4%) resection specimens. FNA was performed on 34 lesions in 33 patients and was considered PanNET in 24 [all confirmed PanNET by histology (10) or follow-up (14)], normal/cyst/unrepresentative in 6 (all confirmed PanNET by follow-up), and adenocarcinoma in 4 (2 confirmed and 2 PanNET). Three patients, all older than 60 years, had a final diagnosis of pancreatic adenocarcinoma. Conclusion: As the accuracy for diagnosing MEN1-related PanNET of MRI was higher than that of CT, MRI should be the preferred (non-invasive) imaging modality for PanNET screening/surveillance. The high diagnostic accuracy of pancreatic imaging and the sporadic occurrence of pancreatic adenocarcinoma question the need for routine (EUS-guided) FNA

    Radiation dose reduction for CT assessment of urolithiasis using iterative reconstruction: A prospective intra-individual study

    Get PDF
    Objective: To assess the performance of hybrid (HIR) and model-based iterative reconstruction (MIR) in patients with urolithiasis at reduced-dose computed tomography (CT). Methods: Twenty patients scheduled for unenhanced abdominal CT for follow-up of urolithiasis were prospectively included. Routine dose acquisition was followed by three low-dose acquisitions at 40%, 60% and 80% reduced doses. All images were reconstructed with filtered back projection (FBP), HIR and MIR. Urolithiasis detection rates, gall bladder, appendix and rectosigmoid evaluation and overall subjective image quality were evaluated by two observers. Results: 74 stones were present in 17 patients. Half the stones were not detected on FBP at the lowest dose level, but this improved with MIR to a sensitivity of 100%. HIR resulted in a slight decrease in sensitivity at the lowest dose to 72%, but outperformed FBP. Evaluation of other structures with HIR at 40% and with MIR at 60% dose reductions was comparable to FBP at routine dose, but 80% dose reduction resulted in non-evaluable images. Conclusions: CT radiation dose for urolithiasis detection can be safely reduced by 40 (HIR)–60 (MIR) % without affecting assessment of urolithiasis, possible extra-urinary tract pathology or overall image quality. Key Points: • Iterative reconstruction can be used to substantially lower the radiation dose. • This allows for radiation reduction without affecting sensitivity of stone detection. • Possible extra-urinary tract pathology evaluation is feasible at 40–60% reduced dose

    Predicting overall survival and resection in patients with locally advanced pancreatic cancer treated with FOLFIRINOX:Development and internal validation of two nomograms

    Get PDF
    Background and Objectives Patients with locally advanced pancreatic cancer (LAPC) are increasingly treated with FOLFIRINOX, resulting in improved survival and resection of tumors that were initially unresectable. It remains unclear, however, which specific patients benefit from FOLFIRINOX. Two nomograms were developed predicting overall survival (OS) and resection at the start of FOLFIRINOX for LAPC. Methods From our multicenter, prospective LAPC registry in 14 Dutch hospitals, LAPC patients starting first-line FOLFIRINOX (April 2015-December 2017) were included. Stepwise backward selection according to the Akaike Information Criterion was used to identify independent baseline predictors for OS and resection. Two prognostic nomograms were generated. Results A total of 252 patients were included, with a median OS of 14 months. Thirty-two patients (13%) underwent resection, with a median OS of 23 months. Older age, female sex, Charlson Comorbidity Index 1, involvement of the superior mesenteric artery, celiac trunk, and superior mesenteric vein >= 270 degrees were independent factors decreasing the probability of resection (c-index: 0.79). Conclusions Two nomograms were developed to predict OS and resection in patients with LAPC before starting treatment with FOLFIRINOX. These nomograms could be beneficial in the shared decision-making process and counseling of these patients

    Single hadron response measurement and calorimeter jet energy scale uncertainty with the ATLAS detector at the LHC

    Get PDF
    The uncertainty on the calorimeter energy response to jets of particles is derived for the ATLAS experiment at the Large Hadron Collider (LHC). First, the calorimeter response to single isolated charged hadrons is measured and compared to the Monte Carlo simulation using proton-proton collisions at centre-of-mass energies of sqrt(s) = 900 GeV and 7 TeV collected during 2009 and 2010. Then, using the decay of K_s and Lambda particles, the calorimeter response to specific types of particles (positively and negatively charged pions, protons, and anti-protons) is measured and compared to the Monte Carlo predictions. Finally, the jet energy scale uncertainty is determined by propagating the response uncertainty for single charged and neutral particles to jets. The response uncertainty is 2-5% for central isolated hadrons and 1-3% for the final calorimeter jet energy scale.Comment: 24 pages plus author list (36 pages total), 23 figures, 1 table, submitted to European Physical Journal

    Measurement of the production cross section for W-bosons in association with jets in pp collisions at s=7 TeV with the ATLAS detector

    Get PDF
    This Letter reports on a first measurement of the inclusive W + jets cross section in proton-proton collisions at a centre-of-mass energy of 7 TeV at the LHC, with the ATLAS detector. Cross sections, in both the electron and muon decay modes of the W-boson, are presented as a function of jet multiplicity and of the transverse momentum of the leading and next-to-leading jets in the event. Measurements are also presented of the ratio of cross sections sigma (W + >= n)/sigma(W + >= n - 1) for inclusive jet multiplicities n = 1-4. The results, based on an integrated luminosity of 1.3 pb(-1), have been corrected for all known detector effects and are quoted in a limited and well-defined range of jet and lepton kinematics. The measured cross sections are compared to particle-level predictions based on perturbative QCD. Next-to-leading order calculations, studied here for n <= 2, are found in good agreement with the data. Leading-order multiparton event generators, normalized to the NNLO total cross section, describe the data well for all measured jet multiplicitie

    Measurement of the flavour composition of dijet events in pp collisions at root s=7 TeV with the ATLAS detector

    Get PDF
    This paper describes a measurement of the flavour composition of dijet events produced in pp collisions at &#8730;s=7 TeV using the ATLAS detector. The measurement uses the full 2010 data sample, corresponding to an integrated luminosity of 39 pb−1. Six possible combinations of light, charm and bottom jets are identified in the dijet events, where the jet flavour is defined by the presence of bottom, charm or solely light flavour hadrons in the jet. Kinematic variables, based on the properties of displaced decay vertices and optimised for jet flavour identification, are used in a multidimensional template fit to measure the fractions of these dijet flavour states as functions of the leading jet transverse momentum in the range 40 GeV to 500 GeV and jet rapidity |y|&#60;2.1. The fit results agree with the predictions of leading- and next-to-leading-order calculations, with the exception of the dijet fraction composed of bottom and light flavour jets, which is underestimated by all models at large transverse jet momenta. The ability to identify jets containing two b-hadrons, originating from e.g. gluon splitting, is demonstrated. The difference between bottom jet production rates in leading and subleading jets is consistent with the next-to-leading-order predictions
    corecore