711 research outputs found
Subchondral bone in osteoarthritis: association between MRI texture analysis and histomorphometry.
OBJECTIVE: Magnetic resonance imaging (MRI) texture analysis is a method of analyzing subchondral bone alterations in osteoarthritis (OA). The objective of this study was to evaluate the association between MR texture analysis and ground-truth subchondral bone histomorphometry at the tibial plateau. DESIGN: The local research ethics committee approved the study. All subjects provided written, informed consent. This was a cross-sectional study carried out at our institution between February and August 2014. Ten participants aged 57-84 with knee OA scheduled for total knee arthroplasty (TKA) underwent pre-operative MRI of the symptomatic knee at 3T using a high spatial-resolution coronal T1 weighted sequence. Tibial plateau explants obtained at the time of TKA underwent histological preparation to allow calculation of bone volume fraction (BV.TV), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp) and trabecular number (Tb.N). Texture analysis was performed on the tibial subchondral bone of MRI images matched to the histological sections. Regression models were created to assess the association of texture analysis features with BV.TV, Tb.Th, Tb.Sp and Tb.N. RESULTS: MRI texture features were significantly associated with BV.TV (R2Â =Â 0.76), Tb.Th (R2Â =Â 0.47), Tb.Sp (R2Â =Â 0.75) and Tb.N (R2Â =Â 0.60, all PÂ <Â 0.001). Simple gray-value histogram based texture features demonstrated the highest standardized regression coefficients for each model. CONCLUSION: MRI texture analysis features were significantly associated with ground-truth subchondral bone histomorphometry at the tibial plateau.Royal College of Radiologists Pump Priming Gran
Systematic review and meta-analysis of the reliability and discriminative validity of cartilage compositional MRI in knee osteoarthritis.
OBJECTIVE: To assess reliability and discriminative validity of cartilage compositional magnetic resonance imaging (MRI) in knee osteoarthritis (OA). DESIGN: The study was carried out per PRISMA recommendations. We searched MEDLINE and EMBASE (1974 - present) for eligible studies. We performed qualitative synthesis of reliability data. Where data from at least two discrimination studies were available, we estimated pooled standardized mean difference (SMD) between subjects with and without OA. Discrimination analyses compared controls and subjects with mild OA (Kellgren-Lawrence (KL) grade 1-2), severe OA (KL grade 3-4) and OA not otherwise specified (NOS) where not possible to stratify. We assessed quality of the evidence using Quality Appraisal of Diagnostic Reliability (QAREL) and Quality Assessment of Diagnostic Accuracy (QUADAS-2) tools. RESULTS: Fifty-eight studies were included in the reliability analysis and 26 studies were included in the discrimination analysis, with data from a total of 2,007 knees. Intra-observer, inter-observer and test-retest reliability of compositional techniques were excellent with most intraclass correlation coefficients >0.8 and coefficients of variation <10%. T1rho and T2 relaxometry were significant discriminators between subjects with mild OA and controls, and between subjects with OA (NOS) and controls (P < 0.001). T1rho showed best discrimination for mild OA (SMD [95% CI] = 0.73 [0.40 to 1.06], P < 0.001) and OA (NOS) (0.60 [0.41 to 0.80], P < 0.001). Quality of evidence was moderate for both parts of the review. CONCLUSIONS: Cartilage compositional MRI techniques are reliable and, in the case of T1rho and T2 relaxometry, can discriminate between subjects with OA and controls
Silent soft tissue pathology is common with a modern metal-on-metal hip arthroplasty: Early detection with routine metal artifact-reduction MRI scanning
Adverse reactions to metal debris have been reported to be a cause of pain in metal-on-metal hip arthroplasty. We assessed the incidence of both symptomatic and asymptomatic adverse reactions in a consecutive series of patients with a modern large-head metal-on-metal hip arthroplasty
Low Spigelian hernia in a 6-year-old boy presenting as an incarcerated inguinal hernia: a case report
<p>Abstract</p> <p>Introduction</p> <p>Lower Spigelian hernia is a very rare entity. The clinical findings are similar to those of inguinal hernias and in many cases may be misdiagnosed. In the literature, only a few references to this entity have been reported in children. To the best of our knowledge, this is the first case report of a lower Spigelian hernia in a child who presented with an acute painful scrotum.</p> <p>Case presentation</p> <p>We discuss the case of a 6-year-old Greek boy who presented to our emergency department complaining of severe pain in the left inguinal area and scrotum. The acute painful swelling started suddenly, without any obvious cause. The initial diagnosis was incarcerated inguinal hernia which was reduced with difficulty. Five days later, the patient still experienced mild pain during palpation and he was operated on. During the operation, a large lower Spigelian hernia was revealed and reconstructed.</p> <p>Conclusion</p> <p>Although Spigelian hernias are rare in children and difficult to diagnose, physicians should be aware of them and include them in the differential diagnosis.</p
Recommended from our members
Changes in the distribution of red foxes (Vulpes vulpes) in urban areas in Great Britain: findings and limitations of a media-driven nationwide survey
Urbanization is one of the major forms of habitat alteration occurring at the present time. Although this is typically deleterious to biodiversity, some species flourish within these human-modified landscapes, potentially leading to negative and/or positive interactions between people and wildlife. Hence, up-to-date assessment of urban wildlife populations is important for developing appropriate management strategies. Surveying urban wildlife is limited by land partition and private ownership, rendering many common survey techniques difficult. Garnering public involvement is one solution, but this method is constrained by the inherent biases of non-standardised survey effort associated with voluntary participation. We used a television-led media approach to solicit national participation in an online sightings survey to investigate changes in the distribution of urban foxes in Great Britain and to explore relationships between urban features and fox occurrence and sightings density. Our results show that media-based approaches can generate a large national database on the current distribution of a recognisable species. Fox distribution in England and Wales has changed markedly within the last 25 years, with sightings submitted from 91% of urban areas previously predicted to support few or no foxes. Data were highly skewed with 90% of urban areas having <30 fox sightings per 1000 people km-2. The extent of total urban area was the only variable with a significant impact on both fox occurrence and sightings density in urban areas; longitude and percentage of public green urban space were respectively, significantly positively and negatively associated with sightings density only. Latitude, and distance to nearest neighbouring conurbation had no impact on either occurrence or sightings density. Given the limitations associated with this method, further investigations are needed to determine the association between sightings density and actual fox density, and variability of fox density within and between urban areas in Britain
What causes increasing and unnecessary use of radiological investigations? a survey of radiologists' perceptions
<p>Abstract</p> <p>Background</p> <p>Growth in use and overuse of diagnostic imaging significantly impacts the quality and costs of health care services. What are the modifiable factors for increasing and unnecessary use of radiological services? Various factors have been indentified, but little is known about their relative impact. Radiologists hold key positions for providing such knowledge. Therefore the purpose of this study was to obtain radiologists' perspective on the causes of increasing and unnecessary use of radiological investigations.</p> <p>Methods</p> <p>In a mailed questionnaire radiologist members of the Norwegian Medical Association were asked to rate potential causes of increased investigation volume (fifteen items) and unnecessary investigations (six items), using five-point-scales. Responses were analysed by using summary statistics and Factor Analysis. Associations between variables were determined using Students' t-test, Spearman rank correlation and Chi-Square tests.</p> <p>Results</p> <p>The response rate was 70% (374/537). The highest rated causes of increasing use of radiological investigations were: a) new radiological technology, b) peoples' demands, c) clinicians' intolerance for uncertainty, d) expanded clinical indications, and e) availability. 'Over-investigation' and 'insufficient referral information' were reported the most frequent causes of unnecessary investigations. Correlations between causes of increasing and unnecessary radiology use were identified.</p> <p>Conclusion</p> <p>In order to manage the growth in radiological imaging and curtail inappropriate investigations, the study findings point to measures that influence the supply and demand of services, specifically to support the decision-making process of physicians.</p
Evidence for the h_b(1P) meson in the decay Upsilon(3S) --> pi0 h_b(1P)
Using a sample of 122 million Upsilon(3S) events recorded with the BaBar
detector at the PEP-II asymmetric-energy e+e- collider at SLAC, we search for
the spin-singlet partner of the P-wave chi_{bJ}(1P) states in the
sequential decay Upsilon(3S) --> pi0 h_b(1P), h_b(1P) --> gamma eta_b(1S). We
observe an excess of events above background in the distribution of the recoil
mass against the pi0 at mass 9902 +/- 4(stat.) +/- 2(syst.) MeV/c^2. The width
of the observed signal is consistent with experimental resolution, and its
significance is 3.1sigma, including systematic uncertainties. We obtain the
value (4.3 +/- 1.1(stat.) +/- 0.9(syst.)) x 10^{-4} for the product branching
fraction BF(Upsilon(3S)-->pi0 h_b) x BF(h_b-->gamma eta_b).Comment: 8 pages, 4 postscript figures, submitted to Phys. Rev. D (Rapid
Communications
Jet energy measurement with the ATLAS detector in proton-proton collisions at root s=7 TeV
The jet energy scale and its systematic uncertainty are determined for jets measured with the ATLAS detector at the LHC in proton-proton collision data at a centre-of-mass energy of âs = 7TeV corresponding to an integrated luminosity of 38 pb-1. Jets are reconstructed with the anti-kt algorithm with distance parameters R=0. 4 or R=0. 6. Jet energy and angle corrections are determined from Monte Carlo simulations to calibrate jets with transverse momenta pTâ„20 GeV and pseudorapidities {pipe}η{pipe}<4. 5. The jet energy systematic uncertainty is estimated using the single isolated hadron response measured in situ and in test-beams, exploiting the transverse momentum balance between central and forward jets in events with dijet topologies and studying systematic variations in Monte Carlo simulations. The jet energy uncertainty is less than 2. 5 % in the central calorimeter region ({pipe}η{pipe}<0. 8) for jets with 60â€pT<800 GeV, and is maximally 14 % for pT<30 GeV in the most forward region 3. 2â€{pipe}η{pipe}<4. 5. The jet energy is validated for jet transverse momenta up to 1 TeV to the level of a few percent using several in situ techniques by comparing a well-known reference such as the recoiling photon pT, the sum of the transverse momenta of tracks associated to the jet, or a system of low-pT jets recoiling against a high-pT jet. More sophisticated jet calibration schemes are presented based on calorimeter cell energy density weighting or hadronic properties of jets, aiming for an improved jet energy resolution and a reduced flavour dependence of the jet response. The systematic uncertainty of the jet energy determined from a combination of in situ techniques is consistent with the one derived from single hadron response measurements over a wide kinematic range. The nominal corrections and uncertainties are derived for isolated jets in an inclusive sample of high-pT jets. Special cases such as event topologies with close-by jets, or selections of samples with an enhanced content of jets originating from light quarks, heavy quarks or gluons are also discussed and the corresponding uncertainties are determined. © 2013 CERN for the benefit of the ATLAS collaboration
Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector
The inclusive and dijet production cross-sections have been measured for jets
containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass
energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The
measurements use data corresponding to an integrated luminosity of 34 pb^-1.
The b-jets are identified using either a lifetime-based method, where secondary
decay vertices of b-hadrons in jets are reconstructed using information from
the tracking detectors, or a muon-based method where the presence of a muon is
used to identify semileptonic decays of b-hadrons inside jets. The inclusive
b-jet cross-section is measured as a function of transverse momentum in the
range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet
cross-section is measured as a function of the dijet invariant mass in the
range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets
and the angular variable chi in two dijet mass regions. The results are
compared with next-to-leading-order QCD predictions. Good agreement is observed
between the measured cross-sections and the predictions obtained using POWHEG +
Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet
cross-section. However, it does not reproduce the measured inclusive
cross-section well, particularly for central b-jets with large transverse
momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final
version published in European Physical Journal
- âŠ