52 research outputs found
Subcutaneous nerve stimulation for rate control in ambulatory dogs with persistent atrial fibrillation
Background
Subcutaneous nerve stimulation (ScNS) damages the stellate ganglion and improves rhythm control of atrial fibrillation (AF) in ambulatory dogs.
Objective
The purpose of this study was to test the hypothesis that thoracic ScNS can improve rate control in persistent AF.
Methods
We created persistent AF in 13 dogs and randomly assigned them to ScNS (n = 6) and sham control (n = 7) groups. 18F-2-Fluoro-2-deoxyglucose positron emission tomography/magnetic resonance imaging of the brain stem was performed at baseline and at the end of the study.
Results
The average stellate ganglion nerve activity reduced from 4.00 ± 1.68 μV after the induction of persistent AF to 1.72 ± 0.42 μV (P = .032) after ScNS. In contrast, the average stellate ganglion nerve activity increased from 3.01 ± 1.26 μV during AF to 5.52 ± 2.69 μV after sham stimulation (P = .023). The mean ventricular rate during persistent AF reduced from 149 ± 36 to 84 ± 16 beats/min (P = .011) in the ScNS group, but no changes were observed in the sham control group. The left ventricular ejection fraction remained unchanged in the ScNS group but reduced significantly in the sham control group. Immunostaining showed damaged ganglion cells in bilateral stellate ganglia and increased brain stem glial cell reaction in the ScNS group but not in the control group. The 18F-2-fluoro-2-deoxyglucose uptake in the pons and medulla was significantly (P = .011) higher in the ScNS group than the sham control group at the end of the study.
Conclusion
Thoracic ScNS causes neural remodeling in the brain stem and stellate ganglia, controls the ventricular rate, and preserves the left ventricular ejection fraction in ambulatory dogs with persistent AF
Cinema-going trajectories in the digital age
The activity of cinema-going constantly evolves and gradually integrates the use of digital data and platforms to become more engaging for the audiences. Combining methods from the fields of Human Computer Interaction and Film Studies, we conducted two workshops seeking to understand cinema audiences’ digital practices and explore how the contemporary cinema-going experience is shaped in the digital age. Our findings suggest that going to the movies constitutes a trajectory during which cinemagoers interact with multiple digital platforms. At the same time, depending on their choices, they construct unique digital identities that represent a set of online behaviours and rituals that cinemagoers adopt before, while and after cinema-going. To inform the design of new, engaging cinemagoing experiences, this research establishes a preliminary map of contemporary cinema-going including digital data and platforms. We then discuss how audiences perceive the potential improvement of the experience and how that would lead to the construction of digital identities
The pipeline project:Pre-publication independent replications of a single laboratory's research pipeline
This crowdsourced project introduces a collaborative approach to improving the reproducibility of scientific research, in which findings are replicated in qualified independent laboratories before (rather than after) they are published. Our goal is to establish a non-adversarial replication process with highly informative final results. To illustrate the Pre-Publication Independent Replication (PPIR) approach, 25 research groups conducted replications of all ten moral judgment effects which the last author and his collaborators had "in the pipeline" as of August 2014. Six findings replicated according to all replication criteria, one finding replicated but with a significantly smaller effect size than the original, one finding replicated consistently in the original culture but not outside of it, and two findings failed to find support. In total, 40% of the original findings failed at least one major replication criterion. Potential ways to implement and incentivize pre-publication independent replication on a large scale are discussed. (C) 2015 The Authors. Published by Elsevier Inc.</p
The pipeline project: Pre-publication independent replications of a single laboratory's research pipeline
This crowdsourced project introduces a collaborative approach to improving the reproducibility of scientific research, in which findings are replicated in qualified independent laboratories before (rather than after) they are published. Our goal is to establish a non-adversarial replication process with highly informative final results. To illustrate the Pre-Publication Independent Replication (PPIR) approach, 25 research groups conducted replications of all ten moral judgment effects which the last author and his collaborators had “in the pipeline” as of August 2014. Six findings replicated according to all replication criteria, one finding replicated but with a significantly smaller effect size than the original, one finding replicated consistently in the original culture but not outside of it, and two findings failed to find support. In total, 40% of the original findings failed at least one major replication criterion. Potential ways to implement and incentivize pre-publication independent replication on a large scale are discussed
Cause of Death and Predictors of All-Cause Mortality in Anticoagulated Patients With Nonvalvular Atrial Fibrillation : Data From ROCKET AF
M. Kaste on työryhmän ROCKET AF Steering Comm jäsen.Background-Atrial fibrillation is associated with higher mortality. Identification of causes of death and contemporary risk factors for all-cause mortality may guide interventions. Methods and Results-In the Rivaroxaban Once Daily Oral Direct Factor Xa Inhibition Compared with Vitamin K Antagonism for Prevention of Stroke and Embolism Trial in Atrial Fibrillation (ROCKET AF) study, patients with nonvalvular atrial fibrillation were randomized to rivaroxaban or dose-adjusted warfarin. Cox proportional hazards regression with backward elimination identified factors at randomization that were independently associated with all-cause mortality in the 14 171 participants in the intention-to-treat population. The median age was 73 years, and the mean CHADS(2) score was 3.5. Over 1.9 years of median follow-up, 1214 (8.6%) patients died. Kaplan-Meier mortality rates were 4.2% at 1 year and 8.9% at 2 years. The majority of classified deaths (1081) were cardiovascular (72%), whereas only 6% were nonhemorrhagic stroke or systemic embolism. No significant difference in all-cause mortality was observed between the rivaroxaban and warfarin arms (P=0.15). Heart failure (hazard ratio 1.51, 95% CI 1.33-1.70, P= 75 years (hazard ratio 1.69, 95% CI 1.51-1.90, P Conclusions-In a large population of patients anticoagulated for nonvalvular atrial fibrillation, approximate to 7 in 10 deaths were cardiovascular, whereasPeer reviewe
A Multilaboratory Comparison of Calibration Accuracy and the Performance of External References in Analytical Ultracentrifugation
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
A multilaboratory comparison of calibration accuracy and the performance of external references in analytical ultracentrifugation.
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304 ± 0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of ± 0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies
The pipeline project: Pre-publication independent replications of a single laboratory's research pipeline
© 2015 The Authors This crowdsourced project introduces a collaborative approach to improving the reproducibility of scientific research, in which findings are replicated in qualified independent laboratories before (rather than after) they are published. Our goal is to establish a non-adversarial replication process with highly informative final results. To illustrate the Pre-Publication Independent Replication (PPIR) approach, 25 research groups conducted replications of all ten moral judgment effects which the last author and his collaborators had âin the pipelineâ as of August 2014. Six findings replicated according to all replication criteria, one finding replicated but with a significantly smaller effect size than the original, one finding replicated consistently in the original culture but not outside of it, and two findings failed to find support. In total, 40% of the original findings failed at least one major replication criterion. Potential ways to implement and incentivize pre-publication independent replication on a large scale are discussed.Link_to_subscribed_fulltex
Development Of Molecularly Imprinted Assays Targeting Peptides And Proteins
Many efforts have been made to produce artificial materials with bio-mimetic properties for diagnostics and life science applications. Among these efforts the technique of molecular imprinting has received much attention, however challenges regarding imprinting of biologically relevant analytes are important to overcome if the technology is to reach its full potential. The lack of generality amongst current molecularly imprinted assay formats is a further discouraging factor against the adoption of molecularly imprinted assays over conventional immunoassays. Whilst many elegant methods for specific templates have been devised, a simple, universal format applicable to any analyte of interest would be a far more attractive prospect. The work presented in this thesis aims to address these challenges. A novel screening tool for optimisation of polymerisation mixtures taking advantage of solid-phase imprinting has been developed and applied to both peptides and proteins. The molecularly imprinted polymers (MIPs) generated in this manner have then been applied to a number of assay formats, with the intention of designing a biologic-free assay for target peptides. The potential application of these techniques has then been demonstrated using a model protein, acetylcholinesterase (AChE). A novel epitope mapping approach has been utilised to identify peptide sequences useful as templates for MIP generation for site specific binding to AChE. Changes in structure and enzymatic activity as a result of binding interactions have been investigated, presenting an opportunity for development of novel allosteric MIP based enzyme activators. The site specific binding has been further exploited in the final application in detection of AChE in a novel sandwich assay format. In this way, it has been demonstrated that this process can be used to identify unknown binding sites on a protein, generate high affinity recognition materials for these sites, and then use these in a generic assay format for detection of the original protein of interest
- …