44 research outputs found

    The Current State of Cephalopod Science and Perspectives on the Most Critical Challenges Ahead From Three Early-Career Researchers

    Get PDF
    International audienceHere, three researchers who have recently embarked on careers in cephalopod biology discuss the current state of the field and offer their hopes for the future. Seven major topics are explored genetics, aquaculture, climate change, welfare, behavior, cognition, and neurobiology. Recent developments in each of these fields are reviewed and the potential of emerging technologies to address specific gaps in knowledge about cephalopods are discussed. Throughout, the authors highlight specific challenges that merit particular focus in the near-term. This review and prospectus is also intended to suggest some concrete near-term goals to cephalopod researchers and inspire those working outside the field to consider the revelatory potential of these remarkable creatures

    Fade slope statistics of 40 GHz beacon signals

    No full text

    Entrain: Encouraging Social Interaction in Collective Music Making

    No full text
    International audienceEntrain is an adaptive agent designed to stimulate social interaction among users in collective music making. It registers individual user behavior and provides sonic feedback to encourage users to look up from their mobiles and interact with each other. We demonstrate a use case of Entrain in Coloop, a distributed and collective musical instrument

    Comparison of Improved Unidirectional Dual Velocity-Encoding MRI Methods

    Get PDF
    Background: In phase-contrast (PC) MRI, several dual velocity encoding methods have been proposed to robustly increase velocity-to-noise ratio (VNR), including a standard dual-VENC (SDV), an optimal dual-VENC (ODV), and bi- and triconditional methods. Purpose: To develop a correction method for the ODV approach and to perform a comparison between methods. Study Type: Case–control study. Population: Twenty-six volunteers. Field Strength/Sequence: 1.5 T phase-contrast MRI with VENCs of 50, 75, and 150 cm/second. Assessment: Since we acquired single-VENC protocols, we used the background phase from high-VENC (VENCH) to reconstruct the low-VENC (VENCL) phase. We implemented and compared the unwrapping methods for different noise levels and also developed a correction of the ODV method. Statistical Tests: Shapiro–Wilk's normality test, two-way analysis of variance with homogeneity of variances was performed using Levene's test, and the significance level was adjusted by Tukey's multiple post hoc analysis with Bonferroni (P < 0.05). Results: Statistical analysis revealed no extreme outliers, normally distributed residuals, and homogeneous variances. We found statistically significant interaction between noise levels and the unwrapping methods. This implies that the number of non-unwrapped pixels increased with the noise level. We found that for β = VENCL/VENCH = 1/2, unwrapping methods were more robust to noise. The post hoc test showed a significant difference between the ODV corrected and the other methods, offering the best results regarding the number of unwrapped pixels. Data Conclusions: All methods performed similarly without noise, but the ODV corrected method was more robust to noise at the price of a higher computational time. Level of Evidence: 4. Technical Efficacy Stage: 1
    corecore