345 research outputs found
Measurement of the top quark mass using the matrix element technique in dilepton final states
We present a measurement of the top quark mass in pp¯ collisions at a center-of-mass energy of 1.96 TeV at the Fermilab Tevatron collider. The data were collected by the D0 experiment corresponding to an integrated luminosity of 9.7 fb−1. The matrix element technique is applied to tt¯ events in the final state containing leptons (electrons or muons) with high transverse momenta and at least two jets. The calibration of the jet energy scale determined in the lepton+jets final state of tt¯ decays is applied to jet energies. This correction provides a substantial reduction in systematic uncertainties. We obtain a top quark mass of mt=173.93±1.84 GeV
Technical and Comparative Aspects of Brain Glycogen Metabolism.
It has been known for over 50 years that brain has significant glycogen stores, but the physiological function of this energy reserve remains uncertain. This uncertainty stems in part from several technical challenges inherent in the study of brain glycogen metabolism, and may also stem from some conceptual limitations. Factors presenting technical challenges include low glycogen content in brain, non-homogenous labeling of glycogen by radiotracers, rapid glycogenolysis during postmortem tissue handling, and effects of the stress response on brain glycogen turnover. Here, we briefly review aspects of glycogen structure and metabolism that bear on these technical challenges, and discuss ways these can be overcome. We also highlight physiological aspects of glycogen metabolism that limit the conditions under which glycogen metabolism can be useful or advantageous over glucose metabolism. Comparisons with glycogen metabolism in skeletal muscle provide an additional perspective on potential functions of glycogen in brain
Recommended from our members
Multiple mechanisms mediating carbon monoxide inhibition of the voltage-gated K+ channel Kv1.5
The voltage-gated K+ channel plays key roles in the vasculature and in atrial excitability, and contributes to apoptosis in various tissues. In this study, we have explored its regulation by carbon monoxide (CO), a product of the cytoprotective heme oxygenase enzymes, and a recognized toxin. CO inhibited recombinant Kv1.5 expressed in HEK293 cells in a concentration-dependent manner which involved multiple signalling pathways. CO inhibition was partially reversed by superoxide dismutase mimetics, and by suppression of mitochondrial reactive oxygen species. CO also elevated intracellular nitric oxide (NO) levels. Prevention of NO formation also partially reversed CO inhibition of Kv1.5, as did inhibition of soluble guanylyl cyclase. CO also elevated intracellular peroxynitrite levels, and a peroxynitrite scavenger markedly attenuated the ability of CO to inhibit Kv1.5. CO caused nitrosylation of Kv1.5, an effect which was also observed in C331A and C346A mutant forms of the channel, which had previously been suggested as nitrosylation sites within Kv1.5. Augmentation of Kv1.5 via exposure to hydrogen peroxide was fully reversed by CO. Native Kv1.5 recorded in HL-1 murine atrial cells was also inhibited by CO. Action potentials recorded in HL-1 cells were increased in amplitude and duration by CO, an effect mimicked and occluded by pharmacological inhibition of Kv1.5. Our data indicate that Kv1.5 is a target for modulation by CO via multiple mechanisms. This regulation has important implications for diverse cellular functions, including excitability, contractility and apoptosis
Osteointegration of soft tissue grafts within the bone tunnels in anterior cruciate ligament reconstruction can be enhanced
Anterior cruciate ligament reconstruction with a soft tissue autograft (hamstring autograft) has grown in popularity in the last 10 years. However, the issues of a relatively long healing time and an inferior histological healing result in terms of Sharpey-like fibers connection in soft tissue grafts are still unsolved. To obtain a promising outcome in the long run, prompt osteointegration of the tendon graft within the bone tunnel is essential. In recent decades, numerous methods have been reported to enhance osteointegration of soft tissue graft in the bone tunnel. In this article, we review the current literature in this research area, mainly focusing on strategies applied to the local bone tunnel environment. Biological strategies such as stem cell and gene transfer technology, as well as the local application of specific growth factors have been reported to yield exciting results. The use of biological bone substitute and physical stimulation also obtained promising results. Artificially engineered tissue has promise as a solution to the problem of donor site morbidity. Despite these encouraging results, the current available evidence is still experimental. Further clinical studies in terms of randomized control trial in the future should be conducted to extrapolate these basic science study findings into clinical practice. © 2009 Springer-Verlag.postprin
Combined Tevatron upper limit on gg->H->W+W- and constraints on the Higgs boson mass in fourth-generation fermion models
Report number: FERMILAB-PUB-10-125-EWe combine results from searches by the CDF and D0 collaborations for a standard model Higgs boson (H) in the process gg->H->W+W- in p=pbar collisions at the Fermilab Tevatron Collider at sqrt{s}=1.96 TeV. With 4.8 fb-1 of integrated luminosity analyzed at CDF and 5.4 fb-1 at D0, the 95% Confidence Level upper limit on \sigma(gg->H) x B(H->W+W-) is 1.75 pb at m_H=120 GeV, 0.38 pb at m_H=165 GeV, and 0.83 pb at m_H=200 GeV. Assuming the presence of a fourth sequential generation of fermions with large masses, we exclude at the 95% Confidence Level a standard-model-like Higgs boson with a mass between 131 and 204 GeV.We combine results from searches by the CDF and D0 collaborations for a standard model Higgs boson (H) in the process gg→H→W+W- in pp̅ collisions at the Fermilab Tevatron Collider at √s=1.96 TeV. With 4.8 fb-1 of integrated luminosity analyzed at CDF and 5.4 fb-1 at D0, the 95% confidence level upper limit on σ(gg→H)×B(H→W+W-) is 1.75 pb at mH=120 GeV, 0.38 pb at mH=165 GeV, and 0.83 pb at mH=200 GeV. Assuming the presence of a fourth sequential generation of fermions with large masses, we exclude at the 95% confidence level a standard-model-like Higgs boson with a mass between 131 and 204 GeV.Peer reviewe
Prediction of cognitive impairment via deep learning trained with multi-center neuropsychological test data
BACKGROUND: Neuropsychological tests (NPTs) are important tools for informing diagnoses of cognitive impairment (CI). However, interpreting NPTs requires specialists and is thus time-consuming. To streamline the application of NPTs in clinical settings, we developed and evaluated the accuracy of a machine learning algorithm using multi-center NPT data.
METHODS: Multi-center data were obtained from 14,926 formal neuropsychological assessments (Seoul Neuropsychological Screening Battery), which were classified into normal cognition (NC), mild cognitive impairment (MCI) and Alzheimer's disease dementia (ADD). We trained a machine learning model with artificial neural network algorithm using TensorFlow (https://www.tensorflow.org) to distinguish cognitive state with the 46-variable data and measured prediction accuracies from 10 randomly selected datasets. The features of the NPT were listed in order of their contribution to the outcome using Recursive Feature Elimination.
RESULTS: The ten times mean accuracies of identifying CI (MCI and ADD) achieved by 96.66 +/- 0.52% of the balanced dataset and 97.23 +/- 0.32% of the clinic-based dataset, and the accuracies for predicting cognitive states (NC, MCI or ADD) were 95.49 +/- 0.53 and 96.34 +/- 1.03%. The sensitivity to the detection CI and MCI in the balanced dataset were 96.0 and 96.0%, and the specificity were 96.8 and 97.4%, respectively. The 'time orientation' and '3-word recall' score of MMSE were highly ranked features in predicting CI and cognitive state. The twelve features reduced from 46 variable of NPTs with age and education had contributed to more than 90% accuracy in predicting cognitive impairment.
CONCLUSIONS: The machine learning algorithm for NPTs has suggested potential use as a reference in differentiating cognitive impairment in the clinical setting
Noise Reduction and Image Quality Improvement of Low Dose and Ultra Low Dose Brain Perfusion CT by HYPR-LR Processing
To evaluate image quality and signal characteristics of brain perfusion CT (BPCT) obtained by low-dose (LD) and ultra-low-dose (ULD) protocols with and without post-processing by highly constrained back-projection (HYPR)–local reconstruction (LR) technique.Simultaneous BPCTs were acquired in 8 patients on a dual-source-CT by applying LD (80 kV,200 mAs,14×1.2 mm) on tube A and ULD (80 kV,30 mAs,14×1.2 mm) on tube B. Image data from both tubes was reconstructed with identical parameters and post-processed using the HYPR-LR. Correlation coefficients between mean and maximum (MAX) attenuation values within corresponding ROIs, area under attenuation curve (AUC), and signal to noise ratio (SNR) of brain parenchyma were assessed. Subjective image quality was assessed on a 5-point scale by two blinded observers (1:excellent, 5:non-diagnostic).Radiation dose of ULD was more than six times lower compared to LD. SNR was improved by HYPR: ULD vs. ULD+HYPR: 1.9±0.3 vs. 8.4±1.7, LD vs. LD+HYPR: 5.0±0.7 vs. 13.4±2.4 (both p<0.0001). There was a good correlation between the original datasets and the HYPR-LR post-processed datasets: r = 0.848 for ULD and ULD+HYPR and r = 0.933 for LD and LD+HYPR (p<0.0001 for both). The mean values of the HYPR-LR post-processed ULD dataset correlated better with the standard LD dataset (r = 0.672) than unprocessed ULD (r = 0.542), but both correlations were significant (p<0.0001). There was no significant difference in AUC or MAX. Image quality was rated excellent (1.3) in LD+HYPR and non-diagnostic (5.0) in ULD. LD and ULD+HYPR images had moderate image quality (3.3 and 2.7).SNR and image quality of ULD-BPCT can be improved to a level similar to LD-BPCT when using HYPR-LR without distorting attenuation measurements. This can be used to substantially reduce radiation dose. Alternatively, LD images can be improved by HYPR-LR to higher diagnostic quality
Influence of lesion and disease subsets on the diagnostic performance of the quantitative flow ratio in real-world patients
The quantitative flow ratio (QFR) is a novel angiography-based computational method assessing functional ischemia caused by coronary stenosis. This study aimed to evaluate the diagnostic performance of quantitative flow ratio (QFR) in patients with angina and acute myocardial infarction (AMI) and to identify the conditions with low diagnostic performance. We assessed the QFR for 1077 vessels under fractional flow ratio (FFR) evaluation in 915 patients with angina and AMI. The diagnostic accuracies of the QFR for identifying an FFR ≤ 0.8 were 95.98% (95% confidence interval [CI] 94.52 to 97.14%) for the angina group and 92.42% (95% CI 86.51 to 96.31%) for the AMI group. The diagnostic accuracy of the QFR in the borderline FFR zones (> 0.75, ≤ 0.85) (91.23% [95% CI 88.25 to 93.66%]) was significantly lower than that in others (difference: 4.32; p = 0.001). The condition accompanying both AMI and the borderline FFR zone showed the lowest QFR diagnostic accuracy in our data (83.93% [95% CI 71.67 to 92.38]). The diagnostic accuracy was reduced for tandem lesions (p = 0.04, not correcting for multiple testing). Our study found that the QFR method yielded a high overall diagnostic performance in real-world patients. However, low diagnostic accuracy has been observed in borderline FFR zones with AMI, and the hybrid FFR approach needs to be considered
Relationship between arterial stiffness and circadian pattern of blood pressure
Arterial stiffness is a risk factor for cardiovascular morbidity and mortality. The relationship between the arterial stiffness and the circadian pattern of blood pressure (BP) has been controversial. The objective of the present study was to investigate the relationship between arterial stiffness by pulse wave analysis (PWA) and variables of 24-hour ambulatory BP monitoring (ABPM) in patients with high normal BP or hypertension (HTN).Five hundred forty-eight patients (304 males, 48 +/- 12-year-old) with high normal BP or HTN were enrolled. BP was measured at the outpatient clinic and 24-hour ABPM was performed. Using radial applanation tonometry, PWA was performed for evaluation of systemic arterial stiffness. Patients were classified into four groups according to the dipping patterns: a nocturnal dipping group, an isolated systolic non-dipping group, an isolated diastolic non-dipping group and a both systolic and diastolic non-dipping group. For adjustment of age, population was divided to 2 groups: old group >/=55 year-old (n = 158, 75 males), young group <55 year-old (n = 390, 229 males).According to the dipping patterns, augmentation pressure (AP), augmentation index (AI) and heart rate (75 bpm) adjusted AI (AI@HR75) showed statistically significant difference (P = .011, .009, and .018, respectively). Multivariate analysis showed that isolated diastolic non-dipping was correlated with arterial stiffness expressed as AI and AI@HR 75, only in young group (beta-coefficient = 12.6, P = .04 and beta-coefficient = 7.503, P = .028, respectively).Arterial stiffness might be closely related with the pattern of non-dipping in young patients with HTN and high normal BP
Relationship between arterial stiffness and variability of home blood pressure monitoring
Variability of blood pressure (BP) is known as a prognostic value for the subsequent target organ damage in hypertensive patients. Arterial stiffness is a risk factor for cardiovascular morbidity and mortality. The relationship between the arterial stiffness and the BP variability has been controversial. The objective of the present study was to investigate the relationship between arterial stiffness and home BP variability in patients with high normal BP and new onset hypertension (HTN).Four hundred sixty three patients (252 males, 49 +/- 12 year-old) with high normal BP or HTN were enrolled. Using radial applanation tonometry, pulse wave analysis (PWA) was performed for evaluation of systemic arterial stiffness. All patients underwent both home BP monitoring (HBPM) and PWA. Home BP variability was calculated as the standard deviation (SD) of 7 measurements of HBPM. Multiple linear regression analysis was performed to estimate and test the independent effects of home BP variability on the arterial stiffness.Mutivariate analysis showed that both systolic and diastolic morning BP variabilities were correlated with arterial stiffness expressed as augmentation pressure (AP, beta-coefficient = 1.622, P = .01 and beta-coefficient = 1.07, P = .035). The SDs of systolic and diastolic BP of evening were also associated with AP (beta-coefficient = 1.843, P = .001 and beta-coefficient = 1.088, P = .036). The SDs of morning and evening systolic BP were associated with augmentation index (AI, beta-coefficient = 1.583, P = .02 and beta-coefficient = 1.792, P = .001) and heart rate (75 bpm) adjusted AI (beta-coefficient = 1.592, P = .001 and beta-coefficient = 1.792, P = .001).In present study, the variability of systolic BP was closely related with arterial stiffness. The home BP variability might be important indicator of arterial stiffness
- …
