9 research outputs found
Recommended from our members
Racial Disparities and the Effect of County Level Income on the Incidence and Survival of Young Men with Anal Cancer.
Purpose: Prior studies have identified a racial disparity in incidence and survival of squamous cell carcinoma of the anus (SCCA) in the young African American male population. We aim to determine whether racial disparities are independent of income and urban location. Methods: The National Cancer Institutes Surveillance of Epidemiology and End Results database was queried for data on patients with SCCA for the years of 2000-2013. Cox regression was used to determine the effect of race, county median family income, rural-urban continuum, and stage of disease on overall survival. Results: The incidence rate of SCCA was significantly higher in black men <50 years old than in white men. Black race had a hazard ratio of 1.55 (confidence interval [CI] 1.33-1.81) when controlling for age, stage, income, and urban-rural status. Each $10,000 increase in county median family income was protective with a hazard ratio of 0.90 (CI 0.86-0.94). Residence in a metropolitan area did not significantly affect survival. Conclusions: The lower survival of black men <50 years old with SCCA is independent of income, urban location, and stage of disease. Further efforts are needed to target this at-risk population and the authors suggest wide application of previously validated screening programs for anal dysplasia
Racial Disparities and the Effect of County Level Income on the Incidence and Survival of Young Men with Anal Cancer
Purpose: Prior studies have identified a racial disparity in incidence and survival of squamous cell carcinoma of the anus (SCCA) in the young African American male population. We aim to determine whether racial disparities are independent of income and urban location.
Methods: The National Cancer Institute's Surveillance of Epidemiology and End Results database was queried for data on patients with SCCA for the years of 2000â2013. Cox regression was used to determine the effect of race, county median family income, ruralâurban continuum, and stage of disease on overall survival.
Results: The incidence rate of SCCA was significantly higher in black men <50 years old than in white men. Black race had a hazard ratio of 1.55 (confidence interval [CI] 1.33â1.81) when controlling for age, stage, income, and urbanârural status. Each $10,000 increase in county median family income was protective with a hazard ratio of 0.90 (CI 0.86â0.94). Residence in a metropolitan area did not significantly affect survival.
Conclusions: The lower survival of black men <50 years old with SCCA is independent of income, urban location, and stage of disease. Further efforts are needed to target this at-risk population and the authors suggest wide application of previously validated screening programs for anal dysplasia
Present criteria for prophylactic ICD implantation: Insights from the EU-CERT-ICD (Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators in EUrope) project
BACKGROUND. The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) completed in 2019 will assess this issue.
SUMMARY. The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicenter observational cohort study done in 44 centers across 15 European countries. A total of 2327 patients with heart failure due to ischemic heart disease or dilated cardiomyopathy indicated for primary prophylactic ICD implantation were recruited between 2014 and 2018 (>1500 patients at first ICD implantation, >750 patients non-randomized non-ICD control group). The primary endpoint was all-cause mortality, first appropriate shock was co-primary endpoint. At baseline, all patients underwent 12-lead ECG and Holter-ECG analysis using multiple advanced methods for risk stratification as well as documentation of clinical characteristics and laboratory values. The EU-CERT-ICD data will provide much needed information on the survival benefit of preventive ICD therapy and expand on previous prospective risk stratification studies which showed very good applicability of clinical parameters and advanced risk stratifiers in order to define patient subgroups with above or below average ICD benefit.
CONCLUSION. The EU-CERT-ICD study will provide new and current data about effectiveness of primary prophylactic ICD implantation. The study also aims for improved risk stratification and patient selection using clinical risk markers in general, and advanced ECG risk markers in particular.peerReviewe
Present criteria for prophylactic ICD implantation:insights from the EU-CERT-ICD (Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators in EUrope) project
Abstract
Background: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) completed in 2019 will assess this issue.
Summary: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicenter observational cohort study done in 44 centers across 15 European countries. A total of 2327 patients with heart failure due to ischemic heart disease or dilated cardiomyopathy indicated for primary prophylactic ICD implantation were recruited between 2014 and 2018 (>1500 patients at first ICD implantation, >750 patients non-randomized non-ICD control group). The primary endpoint was all-cause mortality, and first appropriate shock was co-primary endpoint. At baseline, all patients underwent 12âlead ECG and Holter-ECG analysis using multiple advanced methods for risk stratification as well as documentation of clinical characteristics and laboratory values. The EU-CERT-ICD data will provide much needed information on the survival benefit of preventive ICD therapy and expand on previous prospective risk stratification studies which showed very good applicability of clinical parameters and advanced risk stratifiers in order to define patient subgroups with above or below average ICD benefit.
Conclusion: The EU-CERT-ICD study will provide new and current data about effectiveness of primary prophylactic ICD implantation. The study also aims for improved risk stratification and patient selection using clinical risk markers in general, and advanced ECG risk markers in particular
Rationale and design of the EU-CERT-ICD prospective study: comparative effectiveness of prophylactic ICD implantation
AIMS: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) aims to assess its current clinical value.
METHODS AND RESULTS: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (non-randomized control group). The primary endpoint is all-cause mortality; the co-primary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and cost-effectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12-lead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5Â years.
CONCLUSIONS: The EU-CERT-ICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers.peerReviewe
Rationale and design of the EUâCERTâICD prospective study:comparative effectiveness of prophylactic ICD implantation
Abstract
Aims: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EUâCERTâICD) aims to assess its current clinical value.
Methods and results: The EUâCERTâICD is a prospective investigatorâinitiated nonârandomized, controlled, multicentre observational cohort study performed in 44 centres across 15 European Union countries. We will recruit 2250 patients with ischaemic or dilated cardiomyopathy and a guideline indication for primary prophylactic ICD implantation. This sample will include 1500 patients at their first ICD implantation and 750 patients who did not receive a primary prevention ICD despite having an indication for it (nonârandomized control group). The primary endpoint is allâcause mortality; the coâprimary endpoint in ICD patients is time to first appropriate shock. Secondary endpoints include sudden cardiac death, first inappropriate shock, any ICD shock, arrhythmogenic syncope, revision procedures, quality of life, and costâeffectiveness. At baseline (and prior to ICD implantation if applicable), all patients undergo 12âlead electrocardiogram (ECG) and Holter ECG analysis using multiple advanced methods for risk stratification as well as detailed documentation of clinical characteristics and laboratory values. Genetic biobanking is also organized. As of August 2018, baseline data of 2265 patients are complete. All subjects will be followed for up to 4.5 years.
Conclusions: The EUâCERTâICD study will provide a necessary update about clinical effectiveness of primary prophylactic ICD implantation. This study also aims for improved risk stratification and patient selection using clinical and ECG risk markers