110 research outputs found

    The reality of acoustic power emitted by therapeutic ultrasound equipment: a revision

    Get PDF
    The safety and efficiency of ultrasonic therapy may be compromised if the outlet power on the tranducer differs considerably from the value indicated on the equipment panel. This fact may be seen in the various publications which approach the referenced theme, where various studies determine that over 50% of equipment in routine use in clinics and physiotherapy departments are out of the specifications recommended by the International Electrotechinical Commission (IEC). This occurs as a result of the non regulation of technical production standards, the wear of the equipment itself in use and by the non adoption of routine metrological procedures on the part of the physiotherapist. The precision of the acoustic intensity would enable a more efficient therapy, besides the reproduction of protocols already defined in literature. Another important factor to be pointed out is the material used for coupling the ultrasonic transducer, where of the various means utilized, some propiciate the atenuation of irradiated energy. This revision intends to update the professional therapeutic ultrasound user, as well as make him aware of the need for adopting metrological measures for the equipment in use as routine practice.A segurança e a eficiência da terapia ultra-sônica poderá ser comprometida se a potência de saída no transdutor diferir consideravelmente do valor indicado no painel do equipamento. Este fato pode ser evidenciado nas várias publicações que abordam o referido tema, onde diversos estudos determinam que mais de 50% dos equipamentos, em uso rotineiro, nas clínicas e departamentos de fisioterapia estão fora das especificações postuladas pela International Eletrotechinical Commission (IEC) . Isso ocorre em função da não regulamentação das normas técnicas de produção, do próprio desgaste do equipamento em uso e pela não adoção de procedimentos metrológicos de rotina por parte do fisioterapeuta. A precisão da intensidade acústica irá possibilitar uma terapia mais eficiente, além da reprodução de protocolos já definidos na literatura. Outro importante fator a ser destacado é o material utilizado para o acoplamento do transdutor ultra-sônico, onde evidencia-se que dos vários meios utilizados, alguns propiciam a atenuação da energia irradiada. Esta revisão pretende atualizar o profissional usuário do ultra-som terapêutico, bem como conscientizá-lo da necessidade de adoção de medidas metrológicas como prática de rotina para os equipamentos em uso

    New flavone from the leaves of Neea theifera (Nyctaginaceae)

    Full text link
    Neea theifera Oerst. (Nyctaginaceae) is widely used in Brazilian folk medicine for the treatment of gastric ulcers and inflammation. Phytochemical investigation of the leaves of Neea theifera afforded the isolation of the new flavone luteolin-7-O-[2″-O-(5‴-O-feruloyl)-β-D-apiofuranosyl]- β-D-glucopyranoside (1) besides the eight-known compounds vitexin, isovitexin, isoorientin, orientin, vicenin-2, chrysoeriol, apigenin and luteolin. Their chemical identification was established by NMR spectroscopic methods including 2D-NMR, as well as UV and ESI-MS analyses. ©2007 Sociedade Brasileira de Química

    COMPARAÇÃO MICROBIOLÓGICA ENTRE MEMBRANAS AMNIÓTICAS HUMANAS COLETADAS EM PARTOS VAGINAIS E CESARIANAS – PROJETO PILOTO

    Get PDF
    Objective: The amniotic membrane, a thin membrane, may be used as a temporary cover on deep burns. The objective of this study is to identify the differences regarding bacterial contamination between membranes of vaginal and cesarean deliveries, as well as to assess the possibility of the clinical use of stored membranes.Methods: Twelve membranes were obtained from women submitted to vaginal and cesarean deliveries at the Obstetric Center of Hospital de Clínicas de Porto Alegre. Each amniotic membrane was stored in five different flasks containing a physiological solution. Samples were obtained from these flasks for analysis on days 1, 7, 14, 21 and 28. These samples were tested for bacterial contamination, analyzing its relation to time of storage and type of delivery. This is a pilot study with a transversal design.Results: The comparison between types of delivery yielded a relative risk of contamination in vaginal delivery (RR) of 2.67 (95% CI: 1.09-6.52) and no significance (P = 0.08). No contamination was found on day 1 flasks.Conclusion: All membranes derived from vaginal deliveries ended up showing bacterial contamination during the storage period, which lead to a theoretical unavailability for its use on Amniotic Membrane Banks.Objetivo: A membrana amniótica, uma membrana fina, pode ser utilizada como cobertura temporária em queimaduras profundas. O objetivo deste estudo é o de verificar as possíveis diferenças quanto à contaminação bacteriana entre as membranas de partos cesáreo e vaginal, assim como avaliar a viabilidade ou não do uso clínico-cirúrgico da membrana armazenada.Métodos: Foram coletadas 12 membranas amnióticas de mulheres submetidas a parto cesáreo e vaginal no Centro Obstétrico do HCPA. Cada membrana amniótica foi armazenada em cinco frascos diferentes contendo soro fisiológico, dos quais foram obtidas amostras para análise no momento da coleta e nos dias 7, 14, 21 e 28. Essas amostras foram testadas quanto à contaminação bacteriana, analisando sua relação com o tempo de armazenamento e com o tipo de parto realizado. O estudo é um piloto e tem um delineamento transversal. Resultados: A comparação entre os tipos de parto mostrou um risco relativo (RR) de 2,67 de contaminação no parto vaginal em relação à cesariana (IC de 95%: 1,09 a 6,52), P = 0,08. Não foi verificada contaminação em nenhum dos frascos no momento da coleta. Conclusão: Todas as membranas coletadas de parto vaginal apresentaram crescimento bacteriano no processo de estocagem, levando à sua inviabilidade teórica para uso em Bancos de Membrana Amniótica

    Elliptic flow of charged particles in Pb-Pb collisions at 2.76 TeV

    Get PDF
    We report the first measurement of charged particle elliptic flow in Pb-Pb collisions at 2.76 TeV with the ALICE detector at the CERN Large Hadron Collider. The measurement is performed in the central pseudorapidity region (|η\eta|<0.8) and transverse momentum range 0.2< pTp_{\rm T}< 5.0 GeV/cc. The elliptic flow signal v2_2, measured using the 4-particle correlation method, averaged over transverse momentum and pseudorapidity is 0.087 ±\pm 0.002 (stat) ±\pm 0.004 (syst) in the 40-50% centrality class. The differential elliptic flow v2(pT)_2(p_{\rm T}) reaches a maximum of 0.2 near pTp_{\rm T} = 3 GeV/cc. Compared to RHIC Au-Au collisions at 200 GeV, the elliptic flow increases by about 30%. Some hydrodynamic model predictions which include viscous corrections are in agreement with the observed increase.Comment: 10 pages, 4 captioned figures, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/389
    corecore