363 research outputs found

    Predictors of Cervical Cancer Screening among Infrequently Screened Women Completing Human Papillomavirus Self-Collection: My Body My Test-1

    Get PDF
    Background: Approximately one-half of cervical cancer cases in the United States occur in underscreened or never-screened women. We examined predictors to completing Papanicolaou (Pap) testing and whether a positive human papillomavirus (HPV) self-collection result affects Pap testing adherence among underscreened women. Materials and Methods: Low-income women aged 30-65 years who reported no Pap testing in ≥4 years were recruited in North Carolina. Knowledge, attitudes, and barriers regarding cervical cancer and Pap testing were assessed by telephone questionnaires. We mailed self-collection kits for HPV testing and provided information regarding where to obtain affordable Pap testing. Participants received $45 for completing all activities. We used multivariable logistic regression to assess the predictors of longer reported time since last Pap (≥10 vs. 4-9 years) and of completion of Pap testing following study enrollment (follow-up Pap). Results: Participants (n = 230) were primarily black (55%), uninsured (64%), and with ≤high school education (59%). Cost and finding an affordable clinic were the most commonly reported barriers to screening. White women and those with ≤high school education reported longer intervals since last Pap test. Half of the participants reported completing a follow-up Pap test (55%). Women with a positive HPV self-collection were five times more likely to report completing a follow-up Pap test than those with negative self-collection (odds ratio = 5.1, 95% confidence interval 1.4-25.7). Conclusions: Improving awareness of resources for affordable screening could increase cervical cancer screening in underserved women. Home-based HPV self-collection represents an opportunity to re-engage infrequently screened women into preventive screening services

    Training Psychologists for Rural Practice: Exploring Opportunities and Constraints

    Get PDF
    Purpose: To examine trends in the psychologist workforce and training opportunities, including factors that may influence the decision of clinical psychologists to practice in rural settings. Methods: We use a mixed-methods approach to examine the psychologist workforce nationally and in North Carolina (NC), including (1) an analysis of the location of programs awarding doctoral degrees; (2) an analysis of the practice, demographic, and educational characteristics of the psychologist workforce; and (3) interviews with directors of doctoral programs in clinical psychology to understand where current graduates are getting jobs and why they may or may not be choosing to practice in rural communities. Findings: Fewer than 1% of programs and institutions awarding doctoral degrees in psychology in the United States are located in rural areas. In NC, approximately 80% of practicing psychologists have out-of-state degrees and about 80% of recent NC graduates are not currently licensed in the state. This juxtaposition undermines the utility of adding more in-state degree programs. While expansion of training programs within rural areas could help alleviate the shortages of mental health providers, adding new degree-granting programs alone will not necessarily increase supply. We discuss complementary recruitment and retention strategies, including greater incentives for rural training and practice as well as training in emerging technologies that don't require providers to be physically located in underserved areas, such as telemedicine. Conclusions: Increasing the supply of psychologists practicing in rural areas will require a thoughtful, multipronged approach to training this critical part of the behavioral health workforce

    Preference for Human Papillomavirus Self-Collection and Papanicolaou: Survey of Underscreened Women in North Carolina

    Get PDF
    Objectives Self-collection of samples for human papillomavirus (HPV) testing (self-collection) has the potential to increase cervical cancer screening among underscreened women. We assessed attitudes toward at-home HPV self-collection compared with clinic-based Pap testing in this higher-risk population. Materials and Methods Participants were low-income women in North Carolina overdue for cervical cancer screening. Women self-collected samples at home, returned samples by mail for HPV testing, and completed phone questionnaires about at-home HPV self-collection. Participants were referred to clinic-based Pap testing and invited to complete a second questionnaire about Pap testing. A cross-sectional questionnaire compared attitudes, experiences, and preferences for self-collection versus Pap testing and assessed predictors of preference for HPV self-collection. Results Half (51%) of 221 women reported a preference for HPV self-collection, 19% preferred Pap testing, and 27% reported no preference. More women reported difficulty finding time to do the Pap test (31%) than the self-test (13%, p =.003) and being afraid of the self-test results (50%) than the Pap test results (36%, p =.02). There were relatively fewer reports of physical discomfort and pain from self-collection than Pap testing (discomfort: 18% self; 48% Pap; pain: 8% self; 30% Pap, p =.001). No differences were found in positive versus negative thoughts about the tests, trust in the tests' safety and accuracy, or willingness to do tests again. Conclusions Overall positive attitudes toward HPV self-collection compared with Pap testing among underscreened women suggest that self-collection is a promising option to increase cervical cancer screening in this high-risk population

    Idling Magnetic White Dwarf in the Synchronizing Polar BY Cam. The Noah-2 Project

    Full text link
    Results of a multi-color study of the variability of the magnetic cataclysmic variable BY Cam are presented. The observations were obtained at the Korean 1.8m and Ukrainian 2.6m, 1.2m and 38-cm telescopes in 2003-2005, 56 observational runs cover 189 hours. The variations of the mean brightness in different colors are correlated with a slope dR/dV=1.29(4), where the number in brackets denotes the error estimates in the last digits. For individual runs, this slope is much smaller ranging from 0.98(3) to 1.24(3), with a mean value of 1.11(1). Near the maximum, the slope becomes smaller for some nights, indicating more blue spectral energy distribution, whereas the night-to-night variability has an infrared character. For the simultaneous UBVRI photometry, the slopes increase with wavelength from dU/dR=0.23(1) to dI/dR=1.18(1). Such wavelength dependence is opposite to that observed in non-magnetic cataclysmic variables, in an agreement to the model of cyclotron emission. The principal component analysis shows two (with a third at the limit of detection) components of variablitity with different spectral energy distribution, which possibly correspond to different regions of emission. The scalegram analysis shows a highest peak corresponding to the 200-min spin variability, its quarter and to the 30-min and 8-min QPOs. The amplitudes of all these components are dependent on wavelength and luminosity state. The light curves were fitted by a statistically optimal trigonometrical polynomial (up to 4-th order) to take into account a 4-hump structure. The dependences of these parameters on the phase of the beat period and on mean brightness are discussed. The amplitude of spin variations increases with an increasing wavelength and with decreasing brightnessComment: 30pages, 11figures, accepted in Cent.Eur.J.Phy

    Recruitment strategies and HPV self-collection return rates for under-screened women for cervical cancer prevention

    Get PDF
    In the United States, medically underserved women carry a heavier burden of cancer incidence and mortality, yet are largely underrepresented in cancer prevention studies. My Body, My Test is a n observational cohort, multi-phase cervical cancer prevention study in North Carolina that recruited low-income women, aged 30–65 years and who had not undergone Pap testing in ≥ 4 years. Participants were offered home-based self-collection of cervico-vaginal samples for primary HPV testing. Here, we aimed to describe the recruitment strategies utilized by study staff, and the resulting recruitment and self-collection kit return rates for each specific recruitment strategy. Participants were recruited through different approaches: either direct (active, staff-effort intensive) or indirect (passive on the part of study staff). Of a total of 1,475 individuals screened for eligibility, 695 were eligible (47.1%) and 487 (70% of eligible) participants returned their self-collection kit. Small media recruitment resulted in the highest number of individuals found to be study eligible, with a relatively high self-collection kit return of 70%. In-clinic in-reach resulted in a lower number of study-eligible women, yet had the highest kit return rate (90%) among those sent kits. In contrast, 211 recruitment which resulted in the lowest kit return of 54%. Small media, word of mouth, and face-to-face outreach resulted in self-collection kit return rates ranging from 72 to 79%. The recruitment strategies undertaken by study staff support the continued study of reaching under-screened populations into cervical cancer prevention studies

    All-particle cosmic ray energy spectrum measured with 26 IceTop stations

    Full text link
    We report on a measurement of the cosmic ray energy spectrum with the IceTop air shower array, the surface component of the IceCube Neutrino Observatory at the South Pole. The data used in this analysis were taken between June and October, 2007, with 26 surface stations operational at that time, corresponding to about one third of the final array. The fiducial area used in this analysis was 0.122 km^2. The analysis investigated the energy spectrum from 1 to 100 PeV measured for three different zenith angle ranges between 0{\deg} and 46{\deg}. Because of the isotropy of cosmic rays in this energy range the spectra from all zenith angle intervals have to agree. The cosmic-ray energy spectrum was determined under different assumptions on the primary mass composition. Good agreement of spectra in the three zenith angle ranges was found for the assumption of pure proton and a simple two-component model. For zenith angles {\theta} < 30{\deg}, where the mass dependence is smallest, the knee in the cosmic ray energy spectrum was observed between 3.5 and 4.32 PeV, depending on composition assumption. Spectral indices above the knee range from -3.08 to -3.11 depending on primary mass composition assumption. Moreover, an indication of a flattening of the spectrum above 22 PeV were observed.Comment: 38 pages, 17 figure

    An improved method for measuring muon energy using the truncated mean of dE/dx

    Full text link
    The measurement of muon energy is critical for many analyses in large Cherenkov detectors, particularly those that involve separating extraterrestrial neutrinos from the atmospheric neutrino background. Muon energy has traditionally been determined by measuring the specific energy loss (dE/dx) along the muon's path and relating the dE/dx to the muon energy. Because high-energy muons (E_mu > 1 TeV) lose energy randomly, the spread in dE/dx values is quite large, leading to a typical energy resolution of 0.29 in log10(E_mu) for a muon observed over a 1 km path length in the IceCube detector. In this paper, we present an improved method that uses a truncated mean and other techniques to determine the muon energy. The muon track is divided into separate segments with individual dE/dx values. The elimination of segments with the highest dE/dx results in an overall dE/dx that is more closely correlated to the muon energy. This method results in an energy resolution of 0.22 in log10(E_mu), which gives a 26% improvement. This technique is applicable to any large water or ice detector and potentially to large scintillator or liquid argon detectors.Comment: 12 pages, 16 figure

    Time-integrated luminosity recorded by the BABAR detector at the PEP-II e+e- collider

    Get PDF
    This article is the Preprint version of the final published artcile which can be accessed at the link below.We describe a measurement of the time-integrated luminosity of the data collected by the BABAR experiment at the PEP-II asymmetric-energy e+e- collider at the ϒ(4S), ϒ(3S), and ϒ(2S) resonances and in a continuum region below each resonance. We measure the time-integrated luminosity by counting e+e-→e+e- and (for the ϒ(4S) only) e+e-→μ+μ- candidate events, allowing additional photons in the final state. We use data-corrected simulation to determine the cross-sections and reconstruction efficiencies for these processes, as well as the major backgrounds. Due to the large cross-sections of e+e-→e+e- and e+e-→μ+μ-, the statistical uncertainties of the measurement are substantially smaller than the systematic uncertainties. The dominant systematic uncertainties are due to observed differences between data and simulation, as well as uncertainties on the cross-sections. For data collected on the ϒ(3S) and ϒ(2S) resonances, an additional uncertainty arises due to ϒ→e+e-X background. For data collected off the ϒ resonances, we estimate an additional uncertainty due to time dependent efficiency variations, which can affect the short off-resonance runs. The relative uncertainties on the luminosities of the on-resonance (off-resonance) samples are 0.43% (0.43%) for the ϒ(4S), 0.58% (0.72%) for the ϒ(3S), and 0.68% (0.88%) for the ϒ(2S).This work is supported by the US Department of Energy and National Science Foundation, the Natural Sciences and Engineering Research Council (Canada), the Commissariat à l’Energie Atomique and Institut National de Physique Nucléaire et de Physiquedes Particules (France), the Bundesministerium für Bildung und Forschung and Deutsche Forschungsgemeinschaft (Germany), the Istituto Nazionale di Fisica Nucleare (Italy), the Foundation for Fundamental Research on Matter (The Netherlands), the Research Council of Norway, the Ministry of Education and Science of the Russian Federation, Ministerio de Ciencia e Innovación (Spain), and the Science and Technology Facilities Council (United Kingdom). Individuals have received support from the Marie-Curie IEF program (European Union) and the A.P. Sloan Foundation (USA)

    Measurement of the B0-anti-B0-Oscillation Frequency with Inclusive Dilepton Events

    Get PDF
    The B0B^0-Bˉ0\bar B^0 oscillation frequency has been measured with a sample of 23 million \B\bar B pairs collected with the BABAR detector at the PEP-II asymmetric B Factory at SLAC. In this sample, we select events in which both B mesons decay semileptonically and use the charge of the leptons to identify the flavor of each B meson. A simultaneous fit to the decay time difference distributions for opposite- and same-sign dilepton events gives Δmd=0.493±0.012(stat)±0.009(syst)\Delta m_d = 0.493 \pm 0.012{(stat)}\pm 0.009{(syst)} ps1^{-1}.Comment: 7 pages, 1 figure, submitted to Physical Review Letter

    Observation of the baryonic decay B \uaf 0 \u2192 \u39bc+ p \uaf K-K+

    Get PDF
    We report the observation of the baryonic decay B\uaf0\u2192\u39bc+p\uafK-K+ using a data sample of 471 7106 BB\uaf pairs produced in e+e- annihilations at s=10.58GeV. This data sample was recorded with the BABAR detector at the PEP-II storage ring at SLAC. We find B(B\uaf0\u2192\u39bc+p\uafK-K+)=(2.5\ub10.4(stat)\ub10.2(syst)\ub10.6B(\u39bc+)) 710-5, where the uncertainties are statistical, systematic, and due to the uncertainty of the \u39bc+\u2192pK-\u3c0+ branching fraction, respectively. The result has a significance corresponding to 5.0 standard deviations, including all uncertainties. For the resonant decay B\uaf0\u2192\u39bc+p\uaf\u3c6, we determine the upper limit B(B\uaf0\u2192\u39bc+p\uaf\u3c6)<1.2 710-5 at 90% confidence level
    corecore