2,001 research outputs found

    Multimodal Intrinsic Speckle-Tracking (MIST) to extract rapidly-varying diffuse X-ray scatter

    Full text link
    Speckle-based phase-contrast X-ray imaging (SB-PCXI) can reconstruct high-resolution images of weakly-attenuating materials that would otherwise be indistinguishable in conventional attenuation-based imaging. The experimental setup of SB-PCXI requires only a sufficiently coherent source and spatially random mask, positioned between the source and detector. The technique can extract sample information at length scales smaller than the imaging system's spatial resolution; this enables multimodal signal reconstruction. ``Multimodal Intrinsic Speckle-Tracking'' (MIST) is a rapid and deterministic formalism derived from the paraxial-optics form of the Fokker-Planck equation. MIST simultaneously extracts attenuation, refraction, and small-angle scattering (diffusive-dark-field) signals from a sample and is more computationally efficient compared to alternative speckle-tracking approaches. Hitherto, variants of MIST have assumed the diffusive-dark-field signal to be spatially slowly varying. Although successful, these approaches have been unable to well-describe unresolved sample microstructure whose statistical form is not spatially slowly varying. Here, we extend the MIST formalism such that there is no such restriction, in terms of a sample's rotationally-isotropic diffusive-dark-field signal. We reconstruct multimodal signals of two samples, each with distinct X-ray attenuation and scattering properties. The reconstructed diffusive-dark-field signals have superior image quality compared to our previous approaches which assume the diffusive-dark-field to be a slowly varying function of transverse position. Our generalisation may assist increased adoption of SB-PCXI in applications such as engineering and biomedical disciplines, forestry, and palaeontology, and is anticipated to aid the development of speckle-based diffusive-dark-field tensor tomography.Comment: 18 pages, 7 figure

    Tomographic phase and attenuation extraction for a sample composed of unknown materials using X-ray propagation-based phase-contrast imaging

    Full text link
    Propagation-based phase-contrast X-ray imaging (PB-PCXI) generates image contrast by utilizing sample-imposed phase-shifts. This has proven useful when imaging weakly-attenuating samples, as conventional attenuation-based imaging does not always provide adequate contrast. We present a PB-PCXI algorithm capable of extracting the X-ray attenuation, β\beta, and refraction, δ\delta, components of the complex refractive index of distinct materials within an unknown sample. The method involves curve-fitting an error-function-based model to a phase-retrieved interface in a PB-PCXI tomographic reconstruction, which is obtained when Paganin-type phase-retrieval is applied with incorrect values of δ\delta and β\beta. The fit parameters can then be used to calculate true δ\delta and β\beta values for composite materials. This approach requires no a priori sample information, making it broadly applicable. Our PB-PCXI reconstruction is single distance, requiring only one exposure per tomographic angle, which is important for radiosensitive samples. We apply this approach to a breast-tissue sample, recovering the refraction component, δ\delta, with 0.6 - 2.4\% accuracy compared to theoretical values.Comment: 8 pages, 4 figures and 1 tabl

    Cantor and band spectra for periodic quantum graphs with magnetic fields

    Full text link
    We provide an exhaustive spectral analysis of the two-dimensional periodic square graph lattice with a magnetic field. We show that the spectrum consists of the Dirichlet eigenvalues of the edges and of the preimage of the spectrum of a certain discrete operator under the discriminant (Lyapunov function) of a suitable Kronig-Penney Hamiltonian. In particular, between any two Dirichlet eigenvalues the spectrum is a Cantor set for an irrational flux, and is absolutely continuous and has a band structure for a rational flux. The Dirichlet eigenvalues can be isolated or embedded, subject to the choice of parameters. Conditions for both possibilities are given. We show that generically there are infinitely many gaps in the spectrum, and the Bethe-Sommerfeld conjecture fails in this case.Comment: Misprints correcte

    Analysis of Mechanical Safety of Stadiums for the World Cup 2018

    Get PDF
    It is obvious that contemporary design and construction of unique buildings and structures is unthinkable without mathematical (numerical) and computer modelling and advanced analysis ofload-bearing structures under various kinds ofloads and impacts. One of the most ambitious and important construction projects is the uniquelarge-span structures. These are, in particular, stadiums, sports palaces and water parks, shopping malls, pedestrian, road and railway bridges of various design solutions. The distinctive paper is devoted to theoretical foundations and results of mathematical (numerical) modeling of the state (in terms of the analysis of stress-strain state, strength and stability) of football stadiums built for the 2018 FIFA World Cup in Russia. Finite element method is used for approximation and high-precision numerical solution of corresponding boundary problems of structural mechanics. It is the most universal and powerful numerical method of mechanics. The paper, in particular, describes some features of development of finite element models and the main results of the analysis of the mechanical (structural) safety of three- dimensionallarge-span systems "soil foundation - reinforced concrete structures of foundations and stands - steel structures of the coating and facades" of these football stadiums with the basic and specialload combinations. In addition, the key procedures of scientific support during the corresponding expertise and assessments are outlined. Generally, socially significant and knowledge-intensive problem of providing mechanical (constructive) safety of unique combined objects of construction (three-dimensional systems "foundation - reinforced concrete structures of foundations and stands - steel structures of coating and facades") has been solved at a new level as a result of the performed complex of research works

    Imaging Breast Microcalcifications Using Dark-Field Signal in Propagation-Based Phase-Contrast Tomography

    Get PDF
    Breast microcalcifications are an important primary radiological indicator of breast cancer. However, microcalcification classification and diagnosis may be still challenging for radiologists due to limitations of the standard 2D mammography technique, including spatial and contrast resolution. In this study, we propose an approach to improve the detection of microcalcifications in propagation-based phase-contrast X-ray computed tomography of breast tissues. Five fresh mastectomies containing microcalcifications were scanned at different X-ray energies and radiation doses using synchrotron radiation. Both bright-field (i.e. conventional phase-retrieved images) and dark-field images were extracted from the same data sets using different image processing methods. A quantitative analysis was performed in terms of visibility and contrast-to-noise ratio of microcalcifications. The results show that while the signal-to-noise and the contrast-to-noise ratios are lower, the visibility of the microcalcifications is more than two times higher in the dark-field images compared to the bright-field images. Dark-field images have also provided more accurate information about the size and shape of the microcalcifications

    Study of the production of charged pions, kaons, and protons in pPb collisions at √SNN=5.02 TeV

    Get PDF
    Peer reviewe

    Alignment of the CMS silicon tracker during commissioning with cosmic rays

    Get PDF
    This is the Pre-print version of the Article. The official published version of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe CMS silicon tracker, consisting of 1440 silicon pixel and 15 148 silicon strip detector modules, has been aligned using more than three million cosmic ray charged particles, with additional information from optical surveys. The positions of the modules were determined with respect to cosmic ray trajectories to an average precision of 3–4 microns RMS in the barrel and 3–14 microns RMS in the endcap in the most sensitive coordinate. The results have been validated by several studies, including laser beam cross-checks, track fit self-consistency, track residuals in overlapping module regions, and track parameter resolution, and are compared with predictions obtained from simulation. Correlated systematic effects have been investigated. The track parameter resolutions obtained with this alignment are close to the design performance.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Commissioning and performance of the CMS pixel tracker with cosmic ray muons

    Get PDF
    This is the Pre-print version of the Article. The official published verion of the Paper can be accessed from the link below - Copyright @ 2010 IOPThe pixel detector of the Compact Muon Solenoid experiment consists of three barrel layers and two disks for each endcap. The detector was installed in summer 2008, commissioned with charge injections, and operated in the 3.8 T magnetic field during cosmic ray data taking. This paper reports on the first running experience and presents results on the pixel tracker performance, which are found to be in line with the design specifications of this detector. The transverse impact parameter resolution measured in a sample of high momentum muons is 18 microns.This work is supported by FMSR (Austria); FNRS and FWO (Belgium); CNPq, CAPES, FAPERJ, and FAPESP (Brazil); MES (Bulgaria); CERN; CAS, MoST, and NSFC (China); COLCIENCIAS (Colombia); MSES (Croatia); RPF (Cyprus); Academy of Sciences and NICPB (Estonia); Academy of Finland, ME, and HIP (Finland); CEA and CNRS/IN2P3 (France); BMBF, DFG, and HGF (Germany); GSRT (Greece); OTKA and NKTH (Hungary); DAE and DST (India); IPM (Iran); SFI (Ireland); INFN (Italy); NRF (Korea); LAS (Lithuania); CINVESTAV, CONACYT, SEP, and UASLP-FAI (Mexico); PAEC (Pakistan); SCSR (Poland); FCT (Portugal); JINR (Armenia, Belarus, Georgia, Ukraine, Uzbekistan); MST and MAE (Russia); MSTDS (Serbia); MICINN and CPAN (Spain); Swiss Funding Agencies (Switzerland); NSC (Taipei); TUBITAK and TAEK (Turkey); STFC (United Kingdom); DOE and NSF (USA)

    Performance of the CMS drift-tube chamber local trigger with cosmic rays

    Get PDF
    The performance of the Local Trigger based on the drift-tube system of the CMS experiment has been studied using muons from cosmic ray events collected during the commissioning of the detector in 2008. The properties of the system are extensively tested and compared with the simulation. The effect of the random arrival time of the cosmic rays on the trigger performance is reported, and the results are compared with the design expectations for proton-proton collisions and with previous measurements obtained with muon beams
    corecore