43 research outputs found
The wide-field, multiplexed, spectroscopic facility WEAVE : survey design, overview, and simulated implementation
Funding for the WEAVE facility has been provided by UKRI STFC, the University of Oxford, NOVA, NWO, Instituto de Astrofísica de Canarias (IAC), the Isaac Newton Group partners (STFC, NWO, and Spain, led by the IAC), INAF, CNRS-INSU, the Observatoire de Paris, Région Île-de-France, CONCYT through INAOE, Konkoly Observatory (CSFK), Max-Planck-Institut für Astronomie (MPIA Heidelberg), Lund University, the Leibniz Institute for Astrophysics Potsdam (AIP), the Swedish Research Council, the European Commission, and the University of Pennsylvania.WEAVE, the new wide-field, massively multiplexed spectroscopic survey facility for the William Herschel Telescope, will see first light in late 2022. WEAVE comprises a new 2-degree field-of-view prime-focus corrector system, a nearly 1000-multiplex fibre positioner, 20 individually deployable 'mini' integral field units (IFUs), and a single large IFU. These fibre systems feed a dual-beam spectrograph covering the wavelength range 366-959 nm at R ∼ 5000, or two shorter ranges at R ∼ 20,000. After summarising the design and implementation of WEAVE and its data systems, we present the organisation, science drivers and design of a five- to seven-year programme of eight individual surveys to: (i) study our Galaxy's origins by completing Gaia's phase-space information, providing metallicities to its limiting magnitude for ∼ 3 million stars and detailed abundances for ∼ 1.5 million brighter field and open-cluster stars; (ii) survey ∼ 0.4 million Galactic-plane OBA stars, young stellar objects and nearby gas to understand the evolution of young stars and their environments; (iii) perform an extensive spectral survey of white dwarfs; (iv) survey ∼ 400 neutral-hydrogen-selected galaxies with the IFUs; (v) study properties and kinematics of stellar populations and ionised gas in z 1 million spectra of LOFAR-selected radio sources; (viii) trace structures using intergalactic/circumgalactic gas at z > 2. Finally, we describe the WEAVE Operational Rehearsals using the WEAVE Simulator.PostprintPeer reviewe
The wide-field, multiplexed, spectroscopic facility WEAVE: Survey design, overview, and simulated implementation
WEAVE, the new wide-field, massively multiplexed spectroscopic survey
facility for the William Herschel Telescope, will see first light in late 2022.
WEAVE comprises a new 2-degree field-of-view prime-focus corrector system, a
nearly 1000-multiplex fibre positioner, 20 individually deployable 'mini'
integral field units (IFUs), and a single large IFU. These fibre systems feed a
dual-beam spectrograph covering the wavelength range 366959\,nm at
, or two shorter ranges at . After summarising the
design and implementation of WEAVE and its data systems, we present the
organisation, science drivers and design of a five- to seven-year programme of
eight individual surveys to: (i) study our Galaxy's origins by completing
Gaia's phase-space information, providing metallicities to its limiting
magnitude for 3 million stars and detailed abundances for
million brighter field and open-cluster stars; (ii) survey million
Galactic-plane OBA stars, young stellar objects and nearby gas to understand
the evolution of young stars and their environments; (iii) perform an extensive
spectral survey of white dwarfs; (iv) survey
neutral-hydrogen-selected galaxies with the IFUs; (v) study properties and
kinematics of stellar populations and ionised gas in cluster galaxies;
(vi) survey stellar populations and kinematics in field galaxies
at ; (vii) study the cosmic evolution of accretion
and star formation using million spectra of LOFAR-selected radio sources;
(viii) trace structures using intergalactic/circumgalactic gas at .
Finally, we describe the WEAVE Operational Rehearsals using the WEAVE
Simulator.Comment: 41 pages, 27 figures, accepted for publication by MNRA
Prognostic model to predict postoperative acute kidney injury in patients undergoing major gastrointestinal surgery based on a national prospective observational cohort study.
Background: Acute illness, existing co-morbidities and surgical stress response can all contribute to postoperative acute kidney injury (AKI) in patients undergoing major gastrointestinal surgery. The aim of this study was prospectively to develop a pragmatic prognostic model to stratify patients according to risk of developing AKI after major gastrointestinal surgery. Methods: This prospective multicentre cohort study included consecutive adults undergoing elective or emergency gastrointestinal resection, liver resection or stoma reversal in 2-week blocks over a continuous 3-month period. The primary outcome was the rate of AKI within 7 days of surgery. Bootstrap stability was used to select clinically plausible risk factors into the model. Internal model validation was carried out by bootstrap validation. Results: A total of 4544 patients were included across 173 centres in the UK and Ireland. The overall rate of AKI was 14·2 per cent (646 of 4544) and the 30-day mortality rate was 1·8 per cent (84 of 4544). Stage 1 AKI was significantly associated with 30-day mortality (unadjusted odds ratio 7·61, 95 per cent c.i. 4·49 to 12·90; P < 0·001), with increasing odds of death with each AKI stage. Six variables were selected for inclusion in the prognostic model: age, sex, ASA grade, preoperative estimated glomerular filtration rate, planned open surgery and preoperative use of either an angiotensin-converting enzyme inhibitor or an angiotensin receptor blocker. Internal validation demonstrated good model discrimination (c-statistic 0·65). Discussion: Following major gastrointestinal surgery, AKI occurred in one in seven patients. This preoperative prognostic model identified patients at high risk of postoperative AKI. Validation in an independent data set is required to ensure generalizability
The wide-field, multiplexed, spectroscopic facility WEAVE: Survey design, overview, and simulated implementation
WEAVE, the new wide-field, massively multiplexed spectroscopic survey facility for the William Herschel Telescope, will see first light in late 2022. WEAVE comprises a new 2-degree field-of-view prime-focus corrector system, a nearly 1000-multiplex fibre positioner, 20 individually deployable 'mini' integral field units (IFUs), and a single large IFU. These fibre systems feed a dual-beam spectrograph covering the wavelength range 366−959\,nm at R∼5000, or two shorter ranges at R∼20000. After summarising the design and implementation of WEAVE and its data systems, we present the organisation, science drivers and design of a five- to seven-year programme of eight individual surveys to: (i) study our Galaxy's origins by completing Gaia's phase-space information, providing metallicities to its limiting magnitude for ∼3 million stars and detailed abundances for ∼1.5 million brighter field and open-cluster stars; (ii) survey ∼0.4 million Galactic-plane OBA stars, young stellar objects and nearby gas to understand the evolution of young stars and their environments; (iii) perform an extensive spectral survey of white dwarfs; (iv) survey ∼400 neutral-hydrogen-selected galaxies with the IFUs; (v) study properties and kinematics of stellar populations and ionised gas in z1 million spectra of LOFAR-selected radio sources; (viii) trace structures using intergalactic/circumgalactic gas at z>2. Finally, we describe the WEAVE Operational Rehearsals using the WEAVE Simulator
Evaluation of appendicitis risk prediction models in adults with suspected appendicitis
Background
Appendicitis is the most common general surgical emergency worldwide, but its diagnosis remains challenging. The aim of this study was to determine whether existing risk prediction models can reliably identify patients presenting to hospital in the UK with acute right iliac fossa (RIF) pain who are at low risk of appendicitis.
Methods
A systematic search was completed to identify all existing appendicitis risk prediction models. Models were validated using UK data from an international prospective cohort study that captured consecutive patients aged 16–45 years presenting to hospital with acute RIF in March to June 2017. The main outcome was best achievable model specificity (proportion of patients who did not have appendicitis correctly classified as low risk) whilst maintaining a failure rate below 5 per cent (proportion of patients identified as low risk who actually had appendicitis).
Results
Some 5345 patients across 154 UK hospitals were identified, of which two‐thirds (3613 of 5345, 67·6 per cent) were women. Women were more than twice as likely to undergo surgery with removal of a histologically normal appendix (272 of 964, 28·2 per cent) than men (120 of 993, 12·1 per cent) (relative risk 2·33, 95 per cent c.i. 1·92 to 2·84; P < 0·001). Of 15 validated risk prediction models, the Adult Appendicitis Score performed best (cut‐off score 8 or less, specificity 63·1 per cent, failure rate 3·7 per cent). The Appendicitis Inflammatory Response Score performed best for men (cut‐off score 2 or less, specificity 24·7 per cent, failure rate 2·4 per cent).
Conclusion
Women in the UK had a disproportionate risk of admission without surgical intervention and had high rates of normal appendicectomy. Risk prediction models to support shared decision‐making by identifying adults in the UK at low risk of appendicitis were identified
Tuning Lewis Acidity of Metal–Organic Frameworks via Perfluorination of Bridging Ligands: Spectroscopic, Theoretical, and Catalytic Studies
The Lewis acidity of metal–organic
frameworks (MOFs) has
attracted much research interest in recent years. We report here the
development of two quantitative methods for determining the Lewis
acidity of MOFsbased on electron paramagnetic resonance (EPR)
spectroscopy of MOF-bound superoxide (O<sub>2</sub><sup>•–</sup>) and fluorescence spectroscopy of MOF-bound <i>N</i>-methylacridone
(NMA)and a simple strategy that significantly enhances MOF
Lewis acidity through ligand perfluorination. Two new perfluorinated
MOFs, Zr<sub>6</sub>-fBDC and Zr<sub>6</sub>-fBPDC, where H<sub>2</sub>fBDC is 2,3,5,6-tetrafluoro-1,4-benzenedicarboxylic acid and H<sub>2</sub>fBPDC is 2,2′,3,3′,5,5′,6,6′-octafluoro-4,4′-biphenyldicarboxylic
acid, were shown to be significantly more Lewis acidic than nonsubstituted
UiO-66 and UiO-67 as well as the nitrated MOFs Zr<sub>6</sub>-BDC-NO<sub>2</sub> and Zr<sub>6</sub>-BPDC-(NO<sub>2</sub>)<sub>2</sub>. Zr<sub>6</sub>-fBDC was shown to be a highly active single-site solid Lewis
acid catalyst for Diels–Alder and arene C–H iodination
reactions. Thus, this work establishes the important role of ligand
perfluorination in enhancing MOF Lewis acidity and the potential of
designing highly Lewis acidic MOFs for fine chemical synthesis
Tuning Lewis Acidity of Metal–Organic Frameworks via Perfluorination of Bridging Ligands: Spectroscopic, Theoretical, and Catalytic Studies
The Lewis acidity of metal–organic
frameworks (MOFs) has
attracted much research interest in recent years. We report here the
development of two quantitative methods for determining the Lewis
acidity of MOFsbased on electron paramagnetic resonance (EPR)
spectroscopy of MOF-bound superoxide (O<sub>2</sub><sup>•–</sup>) and fluorescence spectroscopy of MOF-bound <i>N</i>-methylacridone
(NMA)and a simple strategy that significantly enhances MOF
Lewis acidity through ligand perfluorination. Two new perfluorinated
MOFs, Zr<sub>6</sub>-fBDC and Zr<sub>6</sub>-fBPDC, where H<sub>2</sub>fBDC is 2,3,5,6-tetrafluoro-1,4-benzenedicarboxylic acid and H<sub>2</sub>fBPDC is 2,2′,3,3′,5,5′,6,6′-octafluoro-4,4′-biphenyldicarboxylic
acid, were shown to be significantly more Lewis acidic than nonsubstituted
UiO-66 and UiO-67 as well as the nitrated MOFs Zr<sub>6</sub>-BDC-NO<sub>2</sub> and Zr<sub>6</sub>-BPDC-(NO<sub>2</sub>)<sub>2</sub>. Zr<sub>6</sub>-fBDC was shown to be a highly active single-site solid Lewis
acid catalyst for Diels–Alder and arene C–H iodination
reactions. Thus, this work establishes the important role of ligand
perfluorination in enhancing MOF Lewis acidity and the potential of
designing highly Lewis acidic MOFs for fine chemical synthesis