32 research outputs found

    A MHz X-ray diffraction set-up for dynamic compression experiments in the diamond anvil cell

    Get PDF
    An experimental platform for dynamic diamond anvil cell (dDAC) research has been developed at the High Energy Density (HED) Instrument at the European X-ray Free Electron Laser (European XFEL). Advantage was taken of the high repetition rate of the European XFEL (up to 4.5 MHz) to collect pulse-resolved MHz X-ray diffraction data from samples as they are dynamically compressed at intermediate strain rates (≤103 s−1), where up to 352 diffraction images can be collected from a single pulse train. The set-up employs piezo-driven dDACs capable of compressing samples in ≥340 µs, compatible with the maximum length of the pulse train (550 µs). Results from rapid compression experiments on a wide range of sample systems with different X-ray scattering powers are presented. A maximum compression rate of 87 TPa s−1 was observed during the fast compression of Au, while a strain rate of ∼1100 s−1 was achieved during the rapid compression of N2 at 23 TPa s−1

    The LHCb upgrade I

    Get PDF
    The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software

    Southern Region Produce Safety Alliance Grower Training: Using Pre- and Post-Training Knowledge Assessments to Understand Training Effectiveness

    No full text
    The Produce Safety Alliance (PSA) grower training was introduced in 2016 as the standardized curriculum to meet the training requirements of the Food and Drug Administration’s (FDA) Food Safety Modernization Act’s (FSMA) Produce Safety Rule (PSR). The PSR states that at least one supervisor or responsible party from each farm must have successfully completed this food safety training or one equivalent to the standardized curriculum, as recognized by the FDA. This study evaluated the effectiveness of PSA trainings conducted between 2017 and 2019 in the Southern United States by the Southern Regional Center for Food Safety Training, Outreach, and Technical Assistance by analyzing pre- and posttest assessments. Effectiveness was based on a 25-question knowledge assessment administered to participants before (n = 2494) and after (n = 2460) each training. The knowledge assessment indicated the overall effectiveness of the training, with average scores increasing significantly from pretest (15.9/25, 63.4%) to posttest (20.3/25, 81.3%) (P < 0.001). The greatest knowledge gains were seen in the Postharvest Handling and Sanitation, How to Develop a Farm Food Safety Plan, and Agricultural Water modules. Notably, these modules had lower posttest scores compared to the other modules, indicating that the amount of knowledge gained did not necessarily correspond with a sufficient understanding of the material. To ensure that participants understand all aspects of the PSR and best practices to minimize food safety risks, additional or advanced trainings may be needed. Additionally, the current testing instrument (pre-/posttest) used for PSA grower training, while validated, may not be optimal, thus alternative methods to assess the training effectiveness are likely needed
    corecore