1,323 research outputs found

    A method for the determination of trace metals in carbon by atomic absorption spectroscopy

    Get PDF
    The object of this research was to develop an accurate, rapid and economical method for determining trace amounts of metals in carbons, especially in activated carbons designed as gas adsorbents. More specifically, the investigation was directed primarily to the determination of K, Ca, and Fe in Carbon

    Fluorescent and magnetic stellate mesoporous silica for bimodal imaging and magnetic hyperthermia

    Get PDF
    There is currently a crucial need of innovative multifunctional nanoparticles combining, in one formulation, imaging and therapy capacities allowing thus an accurate diagnosis and a therapy monitored by imaging. Multimodal imaging will ensure to speed up diagnosis, and to increase its sensitivity, reliability and specificity for a better management of the disease. Combined with a therapeutic action, it will also enable to treat the disease in a specific personalized manner in feedback mode. The mastered design of such bioprobes as well as the demonstration of their efficiency are still challenges to face in nanomedicine. In this work, novel fluorescent and magnetic core–shell nanocomposites have been designed to ensure, in one nanoformulation, bimodal fluorescence and MRI imaging coupled with therapy by magnetic hyperthermia. They consist in the coating of a magnetic iron oxide (IO) core (ca. 18 nm diameter to ensure magnetic hyperthermia) by an original large pore stellate mesoporous silica (STMS) shell to produce uniform and mono-core magnetic core–shell nanocomposites denoted IO@STMS NPs. To confer fluorescence properties, CdSe/ZnS quantum dots (QDs) NPs were grafted inside the large pores of the IO@STMS nanocomposites. To provide biocompatibility and opsonization-resistance, a tightly-bound human serum albumin (HSA) coating is added around the nanocomposite using an original IBAM-based strategy. Cellular toxicity and non-specific cell–nanomaterial interactions allowed to determine a concentration range for safe application of these NPs. Cellular endosomes containing spontaneously-uptaken NPs displayed strong and photostable QD fluorescence signals while magnetic relaxivity measurements confirm their suitability as contrast agent for MRI. HeLa cell-uptaken NPs exposed to a magnetic field of 100 kHz and 357 Gauss (or 28.5 kA m−1) display an outstanding 65% cell death at a very low iron concentration (1.25 μg Fe mL−1), challenging current magnetic hyperthermia nanosystems. Furthermore, at the particularly demanding conditions of clinical use with low frequency and amplitude field (100 kHz, 117 Gauss or 9.3 kA m−1), magnetic hyperthermia combined with the delivery of a chemotherapeutic drug, doxorubicin, allowed 46% cell death, which neither the drug nor the NPs alone yielded, evidencing thus the synergistic effect of this combined treatment.Facultad de Ciencias VeterinariasInstituto de Investigaciones Fisicoquímicas Teóricas y AplicadasInstituto de Física La Plat

    Measurements of branching fraction ratios and CP-asymmetries in suppressed B^- -> D(-> K^+ pi^-)K^- and B^- -> D(-> K^+ pi^-)pi^- decays

    Get PDF
    We report the first reconstruction in hadron collisions of the suppressed decays B^- -> D(-> K^+ pi^-)K^- and B^- -> D(-> K^+ pi^-)pi^-, sensitive to the CKM phase gamma, using data from 7 fb^-1 of integrated luminosity collected by the CDF II detector at the Tevatron collider. We reconstruct a signal for the B^- -> D(-> K^+ pi^-)K^- suppressed mode with a significance of 3.2 standard deviations, and measure the ratios of the suppressed to favored branching fractions R(K) = [22.0 \pm 8.6(stat)\pm 2.6(syst)]\times 10^-3, R^+(K) = [42.6\pm 13.7(stat)\pm 2.8(syst)]\times 10^-3, R^-(K)= [3.8\pm 10.3(stat)\pm 2.7(syst]\times 10^-3, as well as the direct CP-violating asymmetry A(K) = -0.82\pm 0.44(stat)\pm 0.09(syst) of this mode. Corresponding quantities for B^- -> D(-> K^+ pi^-)pi^- decay are also reported.Comment: 8 pages, 1 figure, accepted by Phys.Rev.D Rapid Communications for Publicatio

    Analysis of shared common genetic risk between amyotrophic lateral sclerosis and epilepsy

    Get PDF
    Because hyper-excitability has been shown to be a shared pathophysiological mechanism, we used the latest and largest genome-wide studies in amyotrophic lateral sclerosis (n = 36,052) and epilepsy (n = 38,349) to determine genetic overlap between these conditions. First, we showed no significant genetic correlation, also when binned on minor allele frequency. Second, we confirmed the absence of polygenic overlap using genomic risk score analysis. Finally, we did not identify pleiotropic variants in meta-analyses of the 2 diseases. Our findings indicate that amyotrophic lateral sclerosis and epilepsy do not share common genetic risk, showing that hyper-excitability in both disorders has distinct origins

    Search for B_s --> mu+mu- and B_d --> mu+mu- Decays with CDF II

    Get PDF
    A search has been performed for B_s --> mu+mu- and B_d --> mu+mu- decays using 7/fb of integrated luminosity collected by the CDF II detector at the Fermilab Tevatron collider. The observed number of B_d candidates is consistent with background-only expectations and yields an upper limit on the branching fraction of BF(B_d-->mu+mu-) < 6.0E-9 at 95% confidence level. We observe an excess of B_s candidates. The probability that the background processes alone could produce such an excess or larger is 0.27%. The probability that the combination of background and the expected standard model rate of B_s --> mu+mu- could produce such an excess or larger is 1.9%. These data are used to determine BF(B_s-->mu+mu-) = (1.8^{+1.1}_{-0.9})E-8 and provide an upper limit of BF(B_s -->mu+mu-) < 4.0E-8 at 95% confidence level.Comment: 7 pages, 1 figure; version accepted by PR

    A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

    Get PDF
    This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model

    Snowmass Neutrino Frontier: DUNE Physics Summary

    Get PDF
    The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of δCP. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter

    Search for strongly interacting massive particles generating trackless jets in proton-proton collisions at s = 13 TeV

    Get PDF
    A search for dark matter in the form of strongly interacting massive particles (SIMPs) using the CMS detector at the LHC is presented. The SIMPs would be produced in pairs that manifest themselves as pairs of jets without tracks. The energy fraction of jets carried by charged particles is used as a key discriminator to suppress efficiently the large multijet background, and the remaining background is estimated directly from data. The search is performed using proton-proton collision data corresponding to an integrated luminosity of 16.1 fb - 1 , collected with the CMS detector in 2016. No significant excess of events is observed above the expected background. For the simplified dark matter model under consideration, SIMPs with masses up to 100 GeV are excluded and further sensitivity is explored towards higher masses

    Measurement of prompt D0^{0} and D\overline{D}0^{0} meson azimuthal anisotropy and search for strong electric fields in PbPb collisions at root SNN\sqrt{S_{NN}} = 5.02 TeV

    Get PDF
    The strong Coulomb field created in ultrarelativistic heavy ion collisions is expected to produce a rapiditydependent difference (Av2) in the second Fourier coefficient of the azimuthal distribution (elliptic flow, v2) between D0 (uc) and D0 (uc) mesons. Motivated by the search for evidence of this field, the CMS detector at the LHC is used to perform the first measurement of Av2. The rapidity-averaged value is found to be (Av2) = 0.001 ? 0.001 (stat)? 0.003 (syst) in PbPb collisions at ?sNN = 5.02 TeV. In addition, the influence of the collision geometry is explored by measuring the D0 and D0mesons v2 and triangular flow coefficient (v3) as functions of rapidity, transverse momentum (pT), and event centrality (a measure of the overlap of the two Pb nuclei). A clear centrality dependence of prompt D0 meson v2 values is observed, while the v3 is largely independent of centrality. These trends are consistent with expectations of flow driven by the initial-state geometry. ? 2021 The Author. Published by Elsevier B.V. This is an open access article under the CC BY licens

    Snowmass Neutrino Frontier: DUNE Physics Summary

    Full text link
    The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment with a primary physics goal of observing neutrino and antineutrino oscillation patterns to precisely measure the parameters governing long-baseline neutrino oscillation in a single experiment, and to test the three-flavor paradigm. DUNE's design has been developed by a large, international collaboration of scientists and engineers to have unique capability to measure neutrino oscillation as a function of energy in a broadband beam, to resolve degeneracy among oscillation parameters, and to control systematic uncertainty using the exquisite imaging capability of massive LArTPC far detector modules and an argon-based near detector. DUNE's neutrino oscillation measurements will unambiguously resolve the neutrino mass ordering and provide the sensitivity to discover CP violation in neutrinos for a wide range of possible values of δCP\delta_{CP}. DUNE is also uniquely sensitive to electron neutrinos from a galactic supernova burst, and to a broad range of physics beyond the Standard Model (BSM), including nucleon decays. DUNE is anticipated to begin collecting physics data with Phase I, an initial experiment configuration consisting of two far detector modules and a minimal suite of near detector components, with a 1.2 MW proton beam. To realize its extensive, world-leading physics potential requires the full scope of DUNE be completed in Phase II. The three Phase II upgrades are all necessary to achieve DUNE's physics goals: (1) addition of far detector modules three and four for a total FD fiducial mass of at least 40 kt, (2) upgrade of the proton beam power from 1.2 MW to 2.4 MW, and (3) replacement of the near detector's temporary muon spectrometer with a magnetized, high-pressure gaseous argon TPC and calorimeter.Comment: Contribution to Snowmass 202
    corecore