612 research outputs found

    Tidal stream resource characterisation in progressive versus standing wave systems

    Get PDF
    Š 2018 The Author(s) Characterisations of the tidal stream resource and its variability over various timescales are crucial for the development of the tidal stream energy industry. To date, no research has compared resource sensitivity in standing wave (when peak currents occur midway between high and low water) and progressive wave (where peak currents occur at high and low water) tidal systems. Here, we compare the flow regimes of standing wave versus progressive wave systems and the associated variations in tidal stream power with applications to device deployment options (floating-platform turbines versus bottom-mounted turbines). We use a validated 3D numerical model (ROMS) of a globally-significant tidal energy shelf sea region (Irish Sea), to test the hypotheses that the influence on potential extractable energy, and suitability for different devices, may be markedly different between these contrasting systems. Power density was also calculated and compared for floating versus bottom-mounted devices using in-situ current data (ADCPs) obtained from a standing wave site and a progressive wave site. We show that progressive wave systems are characterised by velocity-asymmetry over a tidal cycle (i.e. stronger peak flows at high water than at low water), leading to power-asymmetry. Such power asymmetry was shown to have more of an effect on floating device technology, where an assumed turbine depth tracks the sea surface, in contrast to bottom-mounted technology, where the hub height is fixed at a certain position above the sea bed. Shallow, high-flow regions where tidal range is large contained up to 2.5% more power density from bottom-mounted compared with floating turbines; however, there were areas where floating devices were exposed to higher mean currents over a tidal cycle. Standing wave systems, where flow asymmetry is minimised, did not particularly favour either technology. The results highlight the requirement for detailed resource assessments to consider the vertical plane, and are applicable to all potential tidal stream energy sites

    Subclinical iron deficiency is a strong predictor of bacterial vaginosis in early pregnancy

    Get PDF
    BACKGROUND: Bacterial vaginosis (BV) is the single most common vaginal infection in women of childbearing age and associated with a sizeable infectious disease burden among both non-pregnant and pregnant women, including a significantly elevated risk of adverse pregnancy outcome. Overall, little progress has been made in identifying causal factors involved in BV acquisition and persistence. We sought to evaluate maternal iron status in early pregnancy as a putative risk factor for BV, considering that micronutrients, and iron deficiency in particular, affect the host response against bacterial colonization, even in the setting of mild micronutrient deficiencies. METHODS: In a nested case-control study, we compared maternal iron status at entry to prenatal care (mean gestational age 9.2 ± 2.6 weeks) between eighty women with healthy vaginal microflora and eighteen women with vaginosis-like microflora. Vaginal microflora status was assessed by assigning a modified Nugent score to a Gram-stained vaginal smear. Maternal iron status was assayed by an array of conventional erythrocyte and serum indicators for iron status assessment, but also by more sensitive and more specific indicators of iron deficiency, including soluble transferrin receptors (sTfR) as an accurate measure of cellular and tissue iron deficiency and the iron deficiency log(10)[sTfR/ferritin] index as the presently most accurate measure of body storage iron available. RESULTS: We found no statistically significant correlation between vaginal microflora status and routinely assessed iron parameters. In contrast, a highly significant difference between the healthy and vaginosis-like microflora groups of women was shown in mean values of sTfR concentrations (1.15 ± 0.30 mg/L versus 1.37 ± 0.38 mg/L, p = 0.008) and in mean iron deficiency log(10)[sTfR/ferritin] index values (1.57 ± 0.30 versus 1.08 ± 0.56, p = 0.003), indicating a strong association between iron deficiency and vaginosis-like microflora. An sTfR concentration >1.45 mg/L was associated with a 3-fold increased risk (95%CI: 1.4–6.7) of vaginosis-like microflora and after controlling for maternal age, gestational length, body mass, parity, and smoking habits with an adjusted odds ratio of 4.5 (95%CI: 1.4–14.2). CONCLUSION: We conclude that subclinical iron deficiency, presumably resulting from inadequate preconceptional iron supplies, is strongly and independently associated with vaginosis-like microflora during early pregnancy

    Prediction of chronic disability in work-related musculoskeletal disorders: a prospective, population-based study

    Get PDF
    BACKGROUND: Disability associated with work-related musculoskeletal disorders is an increasingly serious societal problem. Although most injured workers return quickly to work, a substantial number do not. The costs of chronic disability to the injured worker, his or her family, employers, and society are enormous. A means of accurate early identification of injured workers at risk for chronic disability could enable these individuals to be targeted for early intervention to promote return to work and normal functioning. The purpose of this study is to develop statistical models that accurately predict chronic work disability from data obtained from administrative databases and worker interviews soon after a work injury. Based on these models, we will develop a brief instrument that could be administered in medical or workers' compensation settings to screen injured workers for chronic disability risk. METHODS: This is a population-based, prospective study. The study population consists of workers who file claims for work-related back injuries or carpal tunnel syndrome (CTS) in Washington State. The Washington State Department of Labor and Industries claims database is reviewed weekly to identify workers with new claims for work-related back injuries and CTS, and these workers are telephoned and invited to participate. Workers who enroll complete a computer-assisted telephone interview at baseline and one year later. The baseline interview assesses sociodemographic, employment-related, biomedical/health care, legal, and psychosocial risk factors. The follow-up interview assesses pain, disability, and work status. The primary outcome is duration of work disability over the year after claim submission, as assessed by administrative data. Secondary outcomes include work disability status at one year, as assessed by both self-report and work disability compensation status (administrative records). A sample size of 1,800 workers with back injuries and 1,200 with CTS will provide adequate statistical power (0.96 for low back and 0.85 for CTS) to predict disability with an alpha of .05 (two-sided) and a hazard ratio of 1.2. Proportional hazards regression models will be constructed to determine the best combination of predictors of work disability duration at one year. Regression models will also be developed for the secondary outcomes

    Inertio-elastic focusing of bioparticles in microchannels at high throughput

    Get PDF
    Controlled manipulation of particles from very large volumes of fluid at high throughput is critical for many biomedical, environmental and industrial applications. One promising approach is to use microfluidic technologies that rely on fluid inertia or elasticity to drive lateral migration of particles to stable equilibrium positions in a microchannel. Here, we report on a hydrodynamic approach that enables deterministic focusing of beads, mammalian cells and anisotropic hydrogel particles in a microchannel at extremely high flow rates. We show that on addition of micromolar concentrations of hyaluronic acid, the resulting fluid viscoelasticity can be used to control the focal position of particles at Reynolds numbers up to Re≈10,000 with corresponding flow rates and particle velocities up to 50 ml min[superscript −1] and 130 m s[superscript −1]. This study explores a previously unattained regime of inertio-elastic fluid flow and demonstrates bioparticle focusing at flow rates that are the highest yet achieved.National Institute for Biomedical Imaging and Bioengineering (U.S.) (P41 BioMicroElectroMechanical Systems Resource Center)National Institute for Biomedical Imaging and Bioengineering (U.S.) (P41 EB002503)National Science Foundation (U.S.). Graduate Research FellowshipUnited States. Army Research Office (Institute for Collaborative Biotechnologies Grant W911NF-09-0001

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Azimuthal anisotropy of charged particles at high transverse momenta in PbPb collisions at sqrt(s[NN]) = 2.76 TeV

    Get PDF
    The azimuthal anisotropy of charged particles in PbPb collisions at nucleon-nucleon center-of-mass energy of 2.76 TeV is measured with the CMS detector at the LHC over an extended transverse momentum (pt) range up to approximately 60 GeV. The data cover both the low-pt region associated with hydrodynamic flow phenomena and the high-pt region where the anisotropies may reflect the path-length dependence of parton energy loss in the created medium. The anisotropy parameter (v2) of the particles is extracted by correlating charged tracks with respect to the event-plane reconstructed by using the energy deposited in forward-angle calorimeters. For the six bins of collision centrality studied, spanning the range of 0-60% most-central events, the observed v2 values are found to first increase with pt, reaching a maximum around pt = 3 GeV, and then to gradually decrease to almost zero, with the decline persisting up to at least pt = 40 GeV over the full centrality range measured.Comment: Replaced with published version. Added journal reference and DO
    • …
    corecore