934 research outputs found

    Collaborative Brain-Computer Interface for Aiding Decision-Making

    Get PDF
    We look at the possibility of integrating the percepts from multiple non-communicating observers as a means of achieving better joint perception and better group decisions. Our approach involves the combination of a brain-computer interface with human behavioural responses. To test ideas in controlled conditions, we asked observers to perform a simple matching task involving the rapid sequential presentation of pairs of visual patterns and the subsequent decision as whether the two patterns in a pair were the same or different. We recorded the response times of observers as well as a neural feature which predicts incorrect decisions and, thus, indirectly indicates the confidence of the decisions made by the observers. We then built a composite neuro-behavioural feature which optimally combines the two measures. For group decisions, we uses a majority rule and three rules which weigh the decisions of each observer based on response times and our neural and neuro-behavioural features. Results indicate that the integration of behavioural responses and neural features can significantly improve accuracy when compared with the majority rule. An analysis of event-related potentials indicates that substantial differences are present in the proximity of the response for correct and incorrect trials, further corroborating the idea of using hybrids of brain-computer interfaces and traditional strategies for improving decision making

    Contributions to early HIV diagnosis among patients linked to care vary by testing venue

    Get PDF
    <p>Abstract</p> <p>Objective</p> <p>Early HIV diagnosis reduces transmission and improves health outcomes; screening in non-traditional settings is increasingly advocated. We compared test venues by the number of new diagnoses successfully linked to the regional HIV treatment center and disease stage at diagnosis.</p> <p>Methods</p> <p>We conducted a retrospective cohort study using structured chart review of newly diagnosed HIV patients successfully referred to the region's only HIV treatment center from 1998 to 2003. Demographics, testing indication, risk profile, and initial CD4 count were recorded.</p> <p>Results</p> <p>There were 277 newly diagnosed patients meeting study criteria. Mean age was 33 years, 77% were male, and 46% were African-American. Median CD4 at diagnosis was 324. Diagnoses were earlier via partner testing at the HIV treatment center (N = 8, median CD4 648, p = 0.008) and with universal screening by the blood bank, military, and insurance companies (N = 13, median CD4 483, p = 0.05) than at other venues. Targeted testing by health care and public health entities based on patient request, risk profile, or patient condition lead to later diagnosis.</p> <p>Conclusion</p> <p>Test venues varied by the number of new diagnoses made and the stage of illness at diagnosis. To improve the rate of early diagnosis, scarce resources should be allocated to maximize the number of new diagnoses at screening venues where diagnoses are more likely to be early or alter testing strategies at test venues where diagnoses are traditionally made late. Efforts to improve early diagnosis should be coordinated longitudinally on a regional basis according to this conceptual paradigm.</p

    Search for Charged Higgs Bosons in e+e- Collisions at \sqrt{s} = 189 GeV

    Full text link
    A search for pair-produced charged Higgs bosons is performed with the L3 detector at LEP using data collected at a centre-of-mass energy of 188.6 GeV, corresponding to an integrated luminosity of 176.4 pb^-1. Higgs decays into a charm and a strange quark or into a tau lepton and its associated neutrino are considered. The observed events are consistent with the expectations from Standard Model background processes. A lower limit of 65.5 GeV on the charged Higgs mass is derived at 95 % confidence level, independent of the decay branching ratio Br(H^{+/-} -> tau nu)

    Search for the standard model Higgs boson at LEP

    Get PDF

    X-ray emission from the Sombrero galaxy: discrete sources

    Get PDF
    We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of ~200 ks. With a detection limit of L_X = 1E37 erg/s and a field of view covering a galactocentric radius of ~30 kpc (11.5 arcminute), 383 sources are detected. Cross-correlation with Spitler et al.'s catalogue of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-rays sources in GCs, presumably low-mass X-ray binaries (LMXBs). We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-low indices (~1.1 for the GC-LF and ~1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC LF at fainter luminosities down to 1E35 erg/s. The derived index rules out a faint-end slope flatter than 1.1 at a 2 sigma significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of ~1.0 below 1E37 erg/s. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic AGNs (52+/-11 [1 sigma]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.Comment: 11 figures, 5 tables, ApJ in pres

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    HIV Testing of At Risk Patients in a Large Integrated Health Care System

    Get PDF
    OBJECTIVE: Early identification of HIV infection is critical for patients to receive life-prolonging treatment and risk-reduction counseling. Understanding HIV screening practices and barriers to HIV testing is an important prelude to designing successful HIV screening programs. Our objective was to evaluate current practice patterns for identification of HIV. METHODS: We used a retrospective cohort analysis of 13,991 at-risk patients seen at 4 large Department of Veterans Affairs (VA) health-care systems. We also reviewed 1,100 medical records of tested patients. We assessed HIV testing rates among at-risk patients, the rationale for HIV testing, and predictors of HIV testing and of HIV infection. RESULTS: Of the 13,991 patients at risk for HIV, only 36% had been HIV-tested. The prevalence of HIV ranged from 1% to 20% among tested patients at the 4 sites. Approximately 90% of patients who were tested had a documented reason for testing. CONCLUSION: One-half to two-thirds of patients at risk for HIV had not been tested within our selected VA sites. Among tested patients, the rationale for HIV testing was well documented. Further testing of at-risk patients could clearly benefit patients who have unidentified HIV infection by providing earlier access to life-prolonging therapy

    Performance of CMS muon reconstruction in pp collision events at sqrt(s) = 7 TeV

    Get PDF
    The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 inverse picobarns of data collected in pp collisions at sqrt(s) = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV is above 95% over the whole region of pseudorapidity covered by the CMS muon system, abs(eta) < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeV is higher than 90% over the full eta range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100 GeV and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation.Comment: Replaced with published version. Added journal reference and DO

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns
    corecore