2,192 research outputs found

    Calibrating and testing tissue equivalent proportional counters with 37Ar

    Get PDF
    A method for testing and calibrating tissue equivalent proportional counters with37Ar is described.37Ar is produced by exposure of argon in its normal isotope composition to thermal neutrons. It is shown that - up to volume ratios of 0.01 of argon to the tissue equivalent gas - there is no appreciable effect of the argon admixture on the function of the proportional counter. Conventional calibration methods with characteristic x-rays or with -particles require modifications of the detectors, and they test only small sub-volumes in the counters. In contrast, argon permits calibrations and tests of the resolution that are representative for the entire counter volume and that do not require changes in detector construction. The method is equally applicable to multi-element proportional counters; it is here exemplified by its application to a long cylindrical counter of simplified design that is part of such a multi-element configuration

    Considerations in relation to off-site emergency procedures and response for nuclear accidents

    Get PDF
    The operation of nuclear facilities has, fortunately, not led to many accidents with off-site consequences. However, it is well-recognised that should a large release of radioactivity occur, the effects in the surrounding area and population will be significant. These effects can be mitigated by developing emergency preparedness and response plans prior to the operation of the nuclear facility that can be exercised regularly and implemented if an accident occurs. This review paper details the various stages of a nuclear accident and the corresponding aspects of an emergency preparedness plan that are relevant to these stages, both from a UK and international perspective. The paper also details how certain aspects of emergency preparedness have been affected by the accident at Fukushima Dai-ichi and as a point of comparison how emergency management plans were implemented following the accidents at Three Mile Island 2 and Chernobyl. In addition, the UK’s economic costing model for nuclear accidents COCO-2, and the UK’s Level-3 Probabilistic Safety Assessment code “PACE” are introduced. Finally, the factors that affect the economic impact of a nuclear accident, especially from a UK standpoint, are described

    Comparison of effective dose and lifetime risk of cancer Incidence of CT attenuation correction acquisitions and radiopharmaceutical administration for myocardial perfusion imaging

    Get PDF
    Objective: To measure the organ dose and calculate effective dose from CT attenuation correction (CTAC) acquisitions from four commonly used gamma camera single photon emission CT/CT systems. Methods: CTAC dosimetry data was collected using thermoluminescent dosemeters on GE Healthcare's Infinia™ Hawkeye™ (GE Healthcare, Buckinghamshire, UK) four- and single-slice systems, Siemens Symbia™ T6 (Siemens Healthcare, Erlangen, Germany) and the Philips Precedence (Philips Healthcare, Amsterdam, Netherlands). Organ and effective dose from the administration of 99mTc-tetrofosmin and 99mTc-sestamibi were calculated using International Commission of Radiological Protection reports 80 and 106. Using these data, the lifetime biological risk was calculated. Results: The Siemens Symbia gave the lowest CTAC dose (1.8mSv) followed by the GE Infinia Hawkeye single- slice (1.9mSv), GE Infinia Hawkeye four-slice (2.5mSv) and Philips Precedence v. 3.0. Doses were significantly lower than the calculated doses from radiopharmaceutical administration (11 and 14mSv for 99mTc-tetrofosmin and 99mTc-sestamibi, respectively). Overall lifetime biological risks were lower, which suggests that using CTAC data posed minimal risk to the patient. Comparison of data for breast tissue demonstrated a higher risk than that from the radiopharmaceutical administration. Conclusion: CTAC doses were confirmed to be much lower than those from radiopharmaceutical administration. The localized nature of the CTAC exposure compared to the radiopharmaceutical biological distribution indicated dose and risk to the breast to be higher. Advances in knowledge: This research proved that CTAC is a comparatively low-dose acquisition. However, it has been shown that there is increased risk for breast tissue especially in the younger patients. As per legislation, justification is required and CTAC should only be used in situations that demonstrate sufficient net benefit

    The presence and dosimetry of radon and thoron in a historical, underground metalliferous mine

    Get PDF
    A combination of long term passive, and short term active radon-222, radon-220 and respective progeny measurements were conducted in both traverse and longitudinal axes of a historical metalliferous underground mine in North Queensland, Australia. While the passive monitor results provided average radon and thoron air concentrations over periods of 70–90 days, active measurements over a four day period provided significantly more detail into the dynamics of radon and progeny concentrations in the naturally ventilated mine environment. Passive monitor concentrations for radon and thoron ranged between 60 and 390 Bq m−3 (mean: 140 ± 55 Bq m−3) and 140 and 2600 Bq m−3 (mean: 1070 ± 510 Bq m−3) respectively, with passive thoron progeny monitors providing a mean concentration of 9 ± 5 Bq m−3EEC. Active measurement mean concentrations for radon, thoron, radon progeny and thoron progeny in the centre of the mine drive were 130 ± 90 Bq m−3, 300 ± 100 Bq m−3, 20 ± 20 Bq m−3EEC and 10 ± 10 Bq m−3EEC respectively.It was identified that thoron passive detector placement is critical in establishing reliable monitoring data, and is the reason for the discrepancy between the active and passive thoron results in this study. Site specific progeny measurements are required for the accurate estimation of dose to persons entering the mine. Based on short term active measurements and passive thoron progeny monitor results, the dose contribution from thoron and progeny in the mine was observed to contribute up to 80% of the total radon/thoron inhalation dose, and therefore should not be underestimated in monitoring programs under similar conditions

    Reducing dose for digital cranial radiography : The increased source to the image-receptor distance approach

    Get PDF
    This investigation proposes that an increased source to the image-receptor distance (SID) technique can be used to optimize occipital frontal and lateral cranial radiographs acquired with direct digital radiography. Although cranial radiography is not performed on a routine basis, it should nonetheless be optimized to keep the dose to the patient as low as reasonably achievable, particularly because it can form part of the facial bone and sinus series. Dose measurements were acquired at various SIDs, and image quality was assessed using visual grading analysis. Statistically significant reductions in the effective dose between 19.2% and 23.9% were obtained when the SID was increased from the standard 100 to 150 cm (P ≤.05), and visual grading analysis scores indicate that image quality remained diagnostically acceptable for both projections. This investigation concludes that increasing the SID effectively optimizes occipital frontal and lateral skull radiographs. Radiology departments must be advised of the benefits of this technique with the goal of introducing an updated reference SID of 150 cm into clinical practice.Peer reviewe

    A COMPARISON OF METHODS FOR SELECTING PREFERRED SOLUTIONS IN MULTIOBJECTIVE DECISION MAKING

    No full text
    ISBN : 978-94-91216-77-0In multiobjective optimization problems, the identified Pareto Frontiers and Sets often contain too many solutions, which make it difficult for the decision maker to select a preferred alternative. To facilitate the selection task, decision making support tools can be used in different instances of the multiobjective optimization search to introduce preferences on the objectives or to give a condensed representation of the solutions on the Pareto Frontier, so as to offer to the decision maker a manageable picture of the solution alternatives. This paper presents a comparison of some a priori and a posteriori decision making support methods, aimed at aiding the decision maker in the selection of the preferred solutions. The considered methods are compared with respect to their application to a case study concerning the optimization of the test intervals of the components of a safety system of a nuclear power plant. The engine for the multiobjective optimization search is based on genetic algorithms

    Do fungi need to be included within environmental radiation protection assessment models?

    Get PDF
    Fungi are used as biomonitors of forest ecosystems, having comparatively high uptakes of anthropogenic and naturally occurring radionuclides. However, whilst they are known to accumulate radionuclides they are not typically considered in radiological assessment tools for environmental (non-human biota) assessment. In this paper the total dose rate to fungi is estimated using the ERICA Tool, assuming different fruiting body geometries, a single ellipsoid and more complex geometries considering the different components of the fruit body and their differing radionuclide contents based upon measurement data. Anthropogenic and naturally occurring radionuclide concentrations from the Mediterranean ecosystem (Spain) were used in this assessment. The total estimated weighted dose rate was in the range 0.31–3.4 μGy/h (5th–95th percentile), similar to natural exposure rates reported for other wild groups. The total estimated dose was dominated by internal exposure, especially from 226Ra and 210Po. Differences in dose rate between complex geometries and a simple ellipsoid model were negligible. Therefore, the simple ellipsoid model is recommended to assess dose rates to fungal fruiting bodies. Fungal mycelium was also modelled assuming a long filament. Using these geometries, assessments for fungal fruiting bodies and mycelium under different scenarios (post-accident, planned release and existing exposure) were conducted, each being based on available monitoring data. The estimated total dose rate in each case was below the ERICA screening benchmark dose, except for the example post-accident existing exposure scenario (the Chernobyl Exclusion Zone) for which a dose rate in excess of 35 μGy/h was estimated for the fruiting body. Estimated mycelium dose rate in this post-accident existing exposure scenario was close to the 400 μGy/h benchmark for plants, although fungi are generally considered to be less radiosensitive than plants. Further research on appropriate mycelium geometries and their radionuclide content is required. Based on the assessments presented in this paper, there is no need to recommend that fungi should be added to the existing assessment tools and frameworks; if required some tools allow a geometry representing fungi to be created and used within a dose assessment

    Human neutrophil kinetics: modeling of stable isotope labeling data supports short blood neutrophil half-lives.

    Get PDF
    Human neutrophils have traditionally been thought to have a short half-life in blood; estimates vary from 4-18 hours. This dogma was recently challenged by stable isotope labeling studies with heavy water which yielded estimates in excess of 3 days. To investigate this disparity we generated new stable isotope labeling data in healthy adult subjects using both heavy water (n=4) and deuterium-labeled glucose (n=9), a compound with more rapid labeling kinetics. To interpret results we developed a novel mechanistic model. We applied this model to both previously-published (n=5) and newly-generated data. We initially constrained the ratio of the blood neutrophil pool to the marrow precursor pool (R=0.26, from published values). Analysis of heavy water datasets yielded turnover rates consistent with a short blood half-life, but parameters, particularly marrow transit-time, were poorly-defined. Analysis of glucose-labeling data yielded more precise estimates of half-life, 0.79 ± 0.25 days (19 hours), and marrow transit-time, 5.80 ± 0.42 days. Substitution of this marrow transit-time in the heavy water analysis gave a better-defined blood half-life, 0.77 ± 0.14 days (18.5 hours), close to glucose-derived values. Allowing R to vary yielded a best-fit value, R=0.19. Reanalysis of the previously-published model and data also revealed the origin of their long estimates for neutrophil half-life, an implicit assumption that R is very large, which is physiologically untenable. We conclude that stable isotope labeling in healthy humans is consistent with a blood neutrophil half-life of less than one day

    Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system: Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models

    Get PDF
    To compare TG43-based and Acuros deterministic radiation transport-based calculations of the BrachyVision treatment planning system (TPS) with corresponding Monte Carlo (MC) simulation results in heterogeneous patient geometries, in order to validate Acuros and quantify the accuracy improvement it marks relative to TG43

    Assessment of natural radioactivity in various commercial tiles used for building purposes in Nigeria

    Get PDF
    In this study, we evaluated the activity concentration of natural radionuclides (226Ra, 232Th and 40K) for fifteen (15) different brands of tile samples used for building purposes in Nigeria. The tile samples were analyzed using High purity Germanium gamma detector. The mean activity concentrations of 226Ra, 232Th, and 40K were observed to be 61.1 �5.5 Bq/kg, 70.2 � 6.08 Bq/kg and 514.7 � 59.8 Bq/kg respectively. Various hazard indices such as absorbed dose rate, external and internal hazard index, annual effective dose rate, Gamma activity Index (Ig) and Alpha Index (Ia) were calculated. The obtained results showed that the mean radium equivalent activity (Raeq), the absorbed dose rate (D), external and internal hazard index, the annual effective dose (AEDR) equivalent, Gamma activity Index (Ig) and Alpha Index (Ia) were: 204.42 Bq/kg, 177.61 nGyh1 , 0.55, 0.77, 0.96 mSvyr1 , 0.74 and 0.32 respectively. The average value of radium equivalent obtained in this study is less than that of the recommended value of 370 Bq/kg but the average values of the other radiological hazards for some samples are found to be slightly above international recommended values except Hex, Hin and AEDE which are within the international reference value of unity. The measured concentrations of these radioactive materials were correlated with other previous result obtained from similar tile materials used in other countries and found to be in good agreement with the international standard, however, the tiles are recommended for decoration purposes in Nigeria
    corecore