946 research outputs found

    Late gadolinium enhancement is common in patients with hypertrophic cardiomyopathy and no clinical risk factors for sudden cardiac death: A single center experience

    Get PDF
    Background: Cardiac magnetic resonance (CMR) is used in the diagnosis and risk stratification of hypertrophic cardiomyopathy (HCM) and can detect myocardial replacement fibrosis (anindependent predictor of adverse cardiac outcomes) using late gadolinium enhancement (LGE).Methods: We retrospectively analysed CMR studies carried out over a 2 year period identifying those which were diagnostic of HCM. 117 cases were analysed. Mean age of subjects was 53 years and 78 (67%) were male. Mean ejection fraction (EF) was 68.3% with a mean left ventricular (LV) mass index of 89.4 g/m2. Hypertrophy was predominantly asymmetric in 94 (80%).Results: All subjects received gadolinium and 80 (68%) had evidence of LGE. LVEF was lower (67 vs. 71%; p = 0.015) and LV mass index higher (94 vs. 81 g/m2; p = 0.007) in the LGE group. The proportion of patients with at least 1 clinical risk factor for sudden cardiac death (SCD) was similar in groups with and without LGE (48% vs. 32%; p = 0.160). In this study, a significant proportion (62%) of patients without clinical risk factors for SCD were found to have LGE on CMR. These patients would not currently be considered for therapy with an implantable cardiac defibrillator.Conclusions: 1. Patients with HCM are at increased risk of SCD, but identifying patients who may benefit from implantable defibrillators is difficult. 2. LGE is associated with adverse cardiovascular outcomes in HCM, but is present in a large proportion of patients. 3. Many patients without clinical risk factors for SCD have LGE and would not currently be considered for an implantable cardiac device

    Temporal changes in field calibration relationships for Aeroqual S500 O3 and NO2 sensor-based monitors

    Get PDF
    Sensor-based monitors are increasingly used to measure air pollutant concentrations, but require calibration under field conditions. We made intermittent comparisons (6 times over 6-month period) between ozone and nitrogen dioxide concentrations measured by Aeroqual gas-sensitive semiconductor (O3) and electrochemical (NO2) sensors (two of each) and reference analysers in the UK Automatic Urban and Rural Network. Each deployment period was split into equal (n = 48 x1-hour) training and test datasets, to derive and test calibration equations respectively. We observed significant bivariate linear relationships between Aeroqual O3 and Reference O3 concentrations, and significant multiple linear relationships between Aeroqual NO2 and both Reference NO2 and Aeroqual O3 concentrations. Changes in monitor responses over time (including apparent baseline drift in O3 sensor output, and discrepancies between the 2 Aeroqual NO2 sensors) resulted in relatively inaccurate concentrations estimates (cf. reference concentrations) from calibration equations derived in the first training period and applied to subsequent test deployments (e.g. NO2 RMSE = 47.2 μg m-3 (n = 286) for a dataset of all test periods combined, for one of the two monitor pairs). Substantial improvements in accuracy of estimated concentrations were achieved by combination of repeated intermittent training data into a single calibration dataset (NO2 RMSE = 8.5 μg m-3 for same test dataset described above). This latter approach to field calibration is recommended

    Providing care for children with tracheostomies: a qualitative interview study with parents and health professionals

    Get PDF
    Abstract Objectives: To explore the experience of caring for children with tracheostomies from the perspectives of parents and health professional caregivers. Design: Qualitative semi-structured interview study Setting: One region in England covered by a tertiary care centre that includes urban and remote rural areas and has a high level of deprivation. Participants: A purposive sample of health professionals and parents who care for children who have, or have had, tracheostomies and who received care at the tertiary care centre. Results: This paper outlines key determinants and mediators of the experiences of caregiving and the impact on psychological and physical health and quality of life of parents and their families, confidence of healthcare providers, and perceived quality of care. For parents, access to care packages and respite care at home as well as communication and relationships with health care providers are key mediators of their experience of caregiving, whereas for health professionals, an essential influence is multi-disciplinary team working and support. We also highlight a range of challenges focused on the shared care space, including: a lack of standardisation in access to different support teams, care packages and respite care; irregular training and updates, and differences in health provider expertise and experiences across departments and shift patterns, exacerbated in some settings by limited contact with children with tracheostomies. Conclusions: Understanding the experiences of caregiving can help inform measures to support caregivers and improve quality standards. Our findings suggest there is a need to facilitate further standardisation of care and support available for parent caregivers and that this may be transferable to other regions. Potential solutions to be explored could include the development of a paediatric tracheostomy service specification, increasing use of paediatric tracheostomy specialist nurse roles, and addressing the emotional and psychological support needs of caregivers

    Heart rate variability and target organ damage in hypertensive patients

    Get PDF
    Background: We evaluated the association between linear standard Heart Rate Variability (HRV) measures and vascular, renal and cardiac target organ damage (TOD). Methods: A retrospective analysis was performed including 200 patients registered in the Regione Campania network (aged 62.4 ± 12, male 64%). HRV analysis was performed by 24-h holter ECG. Renal damage was assessed by estimated glomerular filtration rate (eGFR), vascular damage by carotid intima-media thickness (IMT), and cardiac damage by left ventricular mass index. Results: Significantly lower values of the ratio of low to high frequency power (LF/HF) were found in the patients with moderate or severe eGFR (p-value < 0.001). Similarly, depressed values of indexes of the overall autonomic modulation on heart were found in patients with plaque compared to those with a normal IMT (p-value <0.05). These associations remained significant after adjustment for other factors known to contribute to the development of target organ damage, such as age. Moreover, depressed LF/HF was found also in patients with left ventricular hypertrophy but this association was not significant after adjustment for other factors. Conclusions: Depressed HRV appeared to be associated with vascular and renal TOD, suggesting the involvement of autonomic imbalance in the TOD. However, as the mechanisms by which abnormal autonomic balance may lead to TOD, and, particularly, to renal organ damage are not clearly known, further prospective studies with longitudinal design are needed to determine the association between HRV and the development of TOD

    Search for gravitational wave bursts in LIGO's third science run

    Get PDF
    We report on a search for gravitational wave bursts in data from the three LIGO interferometric detectors during their third science run. The search targets subsecond bursts in the frequency range 100-1100 Hz for which no waveform model is assumed, and has a sensitivity in terms of the root-sum-square (rss) strain amplitude of hrss ~ 10^{-20} / sqrt(Hz). No gravitational wave signals were detected in the 8 days of analyzed data.Comment: 12 pages, 6 figures. Amaldi-6 conference proceedings to be published in Classical and Quantum Gravit

    Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    Get PDF
    The first science run of the LIGO and GEO gravitational wave detectors presented the opportunity to test methods of searching for gravitational waves from known pulsars. Here we present new direct upper limits on the strength of waves from the pulsar PSR J1939+2134 using two independent analysis methods, one in the frequency domain using frequentist statistics and one in the time domain using Bayesian inference. Both methods show that the strain amplitude at Earth from this pulsar is less than a few times 10−2210^{-22}.Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 200

    Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers

    Get PDF
    We study frequency dependent (FD) input-output schemes for signal-recycling interferometers, the baseline design of Advanced LIGO and the current configuration of GEO 600. Complementary to a recent proposal by Harms et al. to use FD input squeezing and ordinary homodyne detection, we explore a scheme which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are sub-optimal among all possible input-output schemes, provide a global noise suppression by the power squeeze factor, while being realizable by using detuned Fabry-Perot cavities as input/output filters. At high frequencies, the two schemes are shown to be equivalent, while at low frequencies our scheme gives better performance than that of Harms et al., and is nearly fully optimal. We then study the sensitivity improvement achievable by these schemes in Advanced LIGO era (with 30-m filter cavities and current estimates of filter-mirror losses and thermal noise), for neutron star binary inspirals, and for narrowband GW sources such as low-mass X-ray binaries and known radio pulsars. Optical losses are shown to be a major obstacle for the actual implementation of these techniques in Advanced LIGO. On time scales of third-generation interferometers, like EURO/LIGO-III (~2012), with kilometer-scale filter cavities, a signal-recycling interferometer with the FD readout scheme explored in this paper can have performances comparable to existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi

    Bronchogenic cyst associated with pericardial defect: Case report and review of the literature

    Get PDF
    Partial defect of the pericardium combined with bronchogenic cyst is a very rare congenital anomaly. We describe the case of a 32-year-old man with a partial defect of the left pericardium and a bronchogenic cyst arising from the border of the pericardial defect. The cyst was successfully resected with the harmonic scalpel by three-port videothoracoscopic approach

    Standalone vertex nding in the ATLAS muon spectrometer

    Get PDF
    A dedicated reconstruction algorithm to find decay vertices in the ATLAS muon spectrometer is presented. The algorithm searches the region just upstream of or inside the muon spectrometer volume for multi-particle vertices that originate from the decay of particles with long decay paths. The performance of the algorithm is evaluated using both a sample of simulated Higgs boson events, in which the Higgs boson decays to long-lived neutral particles that in turn decay to bbar b final states, and pp collision data at √s = 7 TeV collected with the ATLAS detector at the LHC during 2011
    • …
    corecore