114 research outputs found

    Critical Discussion of Ex situ and In situ TEM Measurements on Memristive Devices

    Get PDF
    Memristors are promising candidates for new memory technologies and are capable to mimic synapses in artificial neural networks. The switching in memristive devices occurs typically in few nanometer thin dielectric layers. The direct observation of the switching mechanism is crucial for better comprehension and improvements of memristors. Therefore, in situ experiments are conducted in a transmission electron microscope (TEM). However, sample preparation processes and electron beam irradiation can lead to a chemical and structural modification of the active layers. Moreover, devices may show significant device-to-device variability due to the details of processing parameters. Thus, it is essential to characterize the identical device electrically before microstructural analysis

    Multiscale correlative tomography: an investigation of creep cavitation in 316 stainless steel

    Get PDF
    Creep cavitation in an ex-service nuclear steam header Type 316 stainless steel sample is investigated through a multiscale tomography workflow spanning eight orders of magnitude, combining X-ray computed tomography (CT), plasma focused ion beam (FIB) scanning electron microscope (SEM) imaging and scanning transmission electron microscope (STEM) tomography. Guided by microscale X-ray CT, nanoscale X-ray CT is used to investigate the size and morphology of cavities at a triple point of grain boundaries. In order to understand the factors affecting the extent of cavitation, the orientation and crystallographic misorientation of each boundary is characterised using electron backscatter diffraction (EBSD). Additionally, in order to better understand boundary phase growth, the chemistry of a single boundary and its associated secondary phase precipitates is probed through STEM energy dispersive X-ray (EDX) tomography. The difference in cavitation of the three grain boundaries investigated suggests that the orientation of grain boundaries with respect to the direction of principal stress is important in the promotion of cavity formation

    A New Method for Determining the Composition of Core–Shell Nanoparticles via Dual-EDX+EELS Spectrum Imaging

    Get PDF
    Simultaneously acquired microanalytical X-ray and electron energy loss signals are obtained from a bimetallic core–shell nanoparticle system (FePt@Fe3_3O4_4). The signals are decomposed using independent component analysis and the extracted components are used to separately quantify the composition of the spatially overlapping core and shell phases in the nano-heterostructure. The utilization of the complementary strengths of energy dispersive X-ray and electron energy-loss spectroscopy microanalysis has enabled the quantification of both light and heavy elements in a single spectrum image acquisition.D.R. acknowledges support from the Royal Society’s Newton International Fellowship scheme. P.A.M acknowledges financial support from the European Research Council under the European Union’s Seventh Framework Programme (FP7/ 2007-2013)/ERC grant agreement 291522-3DIMAGE. P.A.M. also acknowledges financial support from the European Union’s Seventh Framework Programme of the European Commission: ESTEEM2, contract number 312483. B.R.K. thanks the UK EPSRC for financial support (EP/J500380/1).This is the author accepted manuscript. The final version is available from Wiley via http://dx.doi.org/10.1002/ppsc.20160009

    Resistance Training Combined With Stretching Increases Tendon Stiffness and Is More Effective Than Stretching Alone in Children With Cerebral Palsy: A Randomized Controlled Trial

    Get PDF
    Aim: Stretching is often used to increase/maintain muscle length and improve joint range of motion (ROM) in children with cerebral palsy (CP). However, outcomes at the muscle (remodeling) and resulting function appear to be highly variable and often unsatisfactory. During passive joint rotation, the Achilles tendon lengthensmore than the in-seriesmedial gastrocnemius muscle in children with CP, which might explain the limited effectiveness of stretching interventions.We aimed to ascertain whether increasing tendon stiffness, by performing resistance training, improves the effectiveness of passive stretching, indicated by an increase in medial gastrocnemius fascicle length. Methods: Sixteen children with CP (Age median [IQR]: 9.6 [8.6, 10.5]) completed the study. Children were randomly assigned to a combined intervention of stretching and strengthening of the calf muscles (n = 9) or a control (stretching-only) group (n = 7). Medial gastrocnemius fascicle length at a resting ankle angle, lengthening during passive joint rotations, and tendon stiffness were assessed by combining dynamometry and ultrasound imaging. The study was registered on clinicaltrials.gov (NCT02766491). Results: Resting fascicle length and tendon stiffness increased more in the intervention group compared to the control group (median [95% CI] increase fascicle length: 2.2 [1.3, 4.3] mm; stiffness: 13.6 [9.9, 17.7] N/mm) Maximum dorsiflexion angle increased equally in both groups. Conclusion: This study provides proof of principle that a combined resistance and stretching intervention can increase tendon stiffness and muscle fascicle length in children with CP. This demonstrates that remodeling of muscle structure is possible with non-invasive interventions in spastic CP

    Muscle and tendon lengthening behaviour of the medial gastrocnemius during ankle joint rotation in children with cerebral palsy.

    Get PDF
    NEW FINDINGS: What is the central question of this study? Which structures of the medial gastrocnemius muscle-tendon unit contribute to its lengthening during joint rotation and thus receive the stretching stimulus? What is the main finding and its importance? We show, for the first time, that muscle and tendon lengthen in a different manner in children with cerebral palsy compared with typically developing children during a similar amount of muscle-tendon unit lengthening or joint rotation. This indicates possible differences in mechanical muscle and tendon properties attributable to cerebral palsy, which are not evident by assessment of muscle function at the level of a joint. ABSTRACT: Children with cerebral palsy (CP) commonly present with reduced ankle range of motion (ROM) attributable, in part, to changes in mechanical properties of the muscle-tendon unit (MTU). Detailed information about how muscle and tendon interact to contribute to joint rotation is currently lacking but might provide essential information to explain the limited effectiveness of stretching interventions in children with CP. The purpose of this study was to quantify which structures contribute to MTU lengthening and thus receive the stretch during passive ankle joint rotation. Fifteen children with CP (age, in mean ± SD, 11.4 ± 3 years) and 16 typically developing (TD) children (age, in mean ± SD, 10.2 ± 3 years) participated. Ultrasound was combined with motion tracking, joint torque and EMG to record fascicle, muscle and tendon lengthening of the medial gastrocnemius during passive ankle joint rotations over the full ROM and a common ROM. In children with CP, relative to MTU lengthening, muscle and fascicles lengthened less (CP, 50.4% of MTU lengthening; TD, 63% of MTU lengthening; P < 0.04) and tendon lengthened more (CP, 49.6% of MTU lengthening; TD, 37% of MTU lengthening; P < 0.01) regardless of the ROM studied. Differences between groups in the amount of lengthening of the underlying structures during a similar amount of joint rotation and MTU displacement indicate possible differences in tissue mechanical properties attributable to CP, which are not evident by assessment at the level of a joint. These factors should be considered when assessing and treating muscle function in children with CP, for example during stretching exercises, because the muscle might not receive much of the applied lengthening stimulus
    • 

    corecore