39 research outputs found
Reliability of clinically relevant 3D foot bone angles from quantitative computed tomography
BACKGROUND: Surgical treatment and clinical management of foot pathology requires accurate, reliable assessment of foot deformities. Foot and ankle deformities are multi-planar and therefore difficult to quantify by standard radiographs. Three-dimensional (3D) imaging modalities have been used to define bone orientations using inertial axes based on bone shape, but these inertial axes can fail to mimic established bone angles used in orthopaedics and clinical biomechanics. To provide improved clinical relevance of 3D bone angles, we developed techniques to define bone axes using landmarks on quantitative computed tomography (QCT) bone surface meshes. We aimed to assess measurement precision of landmark-based, 3D bone-to-bone orientations of hind foot and lesser tarsal bones for expert raters and a template-based automated method. METHODS: Two raters completed two repetitions each for twenty feet (10 right, 10 left), placing anatomic landmarks on the surfaces of calcaneus, talus, cuboid, and navicular. Landmarks were also recorded using the automated, template-based method. For each method, 3D bone axes were computed from landmark positions, and Cardan sequences produced sagittal, frontal, and transverse plane angles of bone-to-bone orientations. Angular reliability was assessed using intraclass correlation coefficients (ICCs) and the root mean square standard deviation (RMS-SD) for intra-rater and inter-rater precision, and rater versus automated agreement. RESULTS: Intra- and inter-rater ICCs were generally high (â„ 0.80), and the ICCs for each rater compared to the automated method were similarly high. RMS-SD intra-rater precision ranged from 1.4 to 3.6° and 2.4 to 6.1°, respectively, for the two raters, which compares favorably to uni-planar radiographic precision. Greatest variability was in Navicular: Talus sagittal plane angle and Cuboid: Calcaneus frontal plane angle. Precision of the automated, atlas-based template method versus the raters was comparable to each raterâs internal precision. CONCLUSIONS: Intra- and inter-rater precision suggest that the landmark-based methods have adequate test-retest reliability for 3D assessment of foot deformities. Agreement of the automated, atlas-based method with the expert raters suggests that the automated method is a valid, time-saving technique for foot deformity assessment. These methods have the potential to improve diagnosis of foot and ankle pathologies by allowing multi-planar quantification of deformities
Neuropathic midfoot deformity: Associations with ankle and subtalar joint motion
BACKGROUND: Neuropathic deformities impair foot and ankle joint mobility, often leading to abnormal stresses and impact forces. The purpose of our study was to determine differences in radiographic measures of hind foot alignment and ankle joint and subtalar joint motion in participants with and without neuropathic midfoot deformities and to determine the relationships between radiographic measures of hind foot alignment to ankle and subtalar joint motion in participants with and without neuropathic midfoot deformities. METHODS: Sixty participants were studied in three groups. Forty participants had diabetes mellitus (DM) and peripheral neuropathy (PN) with 20 participants having neuropathic midfoot deformity due to Charcot neuroarthropathy (CN), while 20 participants did not have deformity. Participants with diabetes and neuropathy with and without deformity were compared to 20 young control participants without DM, PN or deformity. Talar declination and calcaneal inclination angles were assessed on lateral view weight bearing radiograph. Ankle dorsiflexion, plantar flexion and subtalar inversion and eversion were assessed by goniometry. RESULTS: Talar declination angle averaged 34±9, 26±4 and 23±3 degrees in participants with deformity, without deformity and young control participants, respectively (p< 0.010). Calcaneal inclination angle averaged 11±10, 18±9 and 21±4 degrees, respectively (p< 0.010). Ankle plantar flexion motion averaged 23±11, 38±10 and 47±7 degrees (p<0.010). The association between talar declination and calcaneal inclination angles with ankle plantar flexion range of motion is strongest in participants with neuropathic midfoot deformity. Participants with talonavicular and calcaneocuboid dislocations result in the most severe restrictions in ankle joint plantar flexion and subtalar joint inversion motions. CONCLUSIONS: An increasing talar declination angle and decreasing calcaneal inclination angle is associated with decreases in ankle joint plantar flexion motion in individuals with neuropathic midfoot deformity due to CN that may contribute to excessive stresses and ultimately plantar ulceration of the midfoot
Reproducibility of a peripheral quantitative computed tomography scan protocol to measure the material properties of the second metatarsal
Background: Peripheral quantitative computed tomography (pQCT) is an established technology that allows for the measurement of the material properties of bone. Alterations to bone architecture are associated with an increased risk of fracture. Further pQCT research is necessary to identify regions of interest that are prone to fracture risk in people with chronic diseases. The second metatarsal is a common site for the development of insufficiency fractures, and as such the aim of this study was to assess the reproducibility of a novel scanning protocol of the second metatarsal using pQCT. Methods. Eleven embalmed cadaveric leg specimens were scanned six times; three times with and without repositioning. Each foot was positioned on a custom-designed acrylic foot plate to permit unimpeded scans of the region of interest. Sixty-six scans were obtained at 15% (distal) and 50% (mid shaft) of the second metatarsal. Voxel size and scan speed were reduced to 0.40 mm and 25 mm.sec-1. The reference line was positioned at the most distal portion of the 2nd metatarsal. Repeated measurements of six key variables related to bone properties were subject to reproducibility testing. Data were log transformed and reproducibility of scans were assessed using intraclass correlation coefficients (ICC) and coefficients of variation (CV%). Results: Reproducibility of the measurements without repositioning were estimated as: trabecular area (ICC 0.95; CV% 2.4), trabecular density (ICC 0.98; CV% 3.0), Strength Strain Index (SSI) - distal (ICC 0.99; CV% 5.6), cortical area (ICC 1.0; CV% 1.5), cortical density (ICC 0.99; CV% 0.1), SSI - mid shaft (ICC 1.0; CV% 2.4). Reproducibility of the measurements after repositioning were estimated as: trabecular area (ICC 0.96; CV% 2.4), trabecular density (ICC 0.98; CV% 2.8), SSI - distal (ICC 1.0; CV% 3.5), cortical area (ICC 0.99; CV%2.4), cortical density (ICC 0.98; CV% 0.8), SSI - mid shaft (ICC 0.99; CV% 3.2). Conclusions: The scanning protocol generated excellent reproducibility for key bone properties measured at the distal and mid-shaft regions of the 2 nd metatarsal. This protocol extends the capabilities of pQCT to evaluate bone quality in people who may be at an increased risk of metatarsal insufficiency fractures
Global carbon budget 2019
Accurate assessment of anthropogenic carbon dioxide (CO2) emissions and their redistribution among the atmosphere, ocean, and terrestrial biosphere â the âglobal carbon budgetâ â is important to better understand the global carbon cycle, support the development of climate policies, and project future climate change. Here we describe data sets and methodology to quantify the five major components of the global carbon budget and their uncertainties. Fossil CO2 emissions (EFF) are based on energy statistics and cement production data, while emissions from land use change (ELUC), mainly deforestation, are based on land use and land use change data and bookkeeping models. Atmospheric CO2 concentration is measured directly and its growth rate (GATM) is computed from the annual changes in concentration. The ocean CO2 sink (SOCEAN) and terrestrial CO2 sink (SLAND) are estimated with global process models constrained by observations. The resulting carbon budget imbalance (BIM), the difference between the estimated total emissions and the estimated changes in the atmosphere, ocean, and terrestrial biosphere, is a measure of imperfect data and understanding of the contemporary carbon cycle. All uncertainties are reported as ±1Ï. For the last decade available (2009â2018), EFF was 9.5±0.5âGtCâyrâ1, ELUC 1.5±0.7âGtCâyrâ1, GATM 4.9±0.02âGtCâyrâ1 (2.3±0.01âppmâyrâ1), SOCEAN 2.5±0.6âGtCâyrâ1, and SLAND 3.2±0.6âGtCâyrâ1, with a budget imbalance BIM of 0.4âGtCâyrâ1 indicating overestimated emissions and/or underestimated sinks. For the year 2018 alone, the growth in EFF was about 2.1â% and fossil emissions increased to 10.0±0.5âGtCâyrâ1, reaching 10âGtCâyrâ1 for the first time in history, ELUC was 1.5±0.7âGtCâyrâ1, for total anthropogenic CO2 emissions of 11.5±0.9âGtCâyrâ1 (42.5±3.3âGtCO2). Also for 2018, GATM was 5.1±0.2âGtCâyrâ1 (2.4±0.1âppmâyrâ1), SOCEAN was 2.6±0.6âGtCâyrâ1, and SLAND was 3.5±0.7âGtCâyrâ1, with a BIM of 0.3âGtC. The global atmospheric CO2 concentration reached 407.38±0.1âppm averaged over 2018. For 2019, preliminary data for the first 6â10 months indicate a reduced growth in EFF of +0.6â% (range of â0.2â% to 1.5â%) based on national emissions projections for China, the USA, the EU, and India and projections of gross domestic product corrected for recent changes in the carbon intensity of the economy for the rest of the world. Overall, the mean and trend in the five components of the global carbon budget are consistently estimated over the period 1959â2018, but discrepancies of up to 1âGtCâyrâ1 persist for the representation of semi-decadal variability in CO2 fluxes. A detailed comparison among individual estimates and the introduction of a broad range of observations shows (1) no consensus in the mean and trend in land use change emissions over the last decade, (2) a persistent low agreement between the different methods on the magnitude of the land CO2 flux in the northern extra-tropics, and (3) an apparent underestimation of the CO2 variability by ocean models outside the tropics. This living data update documents changes in the methods and data sets used in this new global carbon budget and the progress in understanding of the global carbon cycle compared with previous publications of this data set (Le QuĂ©rĂ© et al., 2018a, b, 2016, 2015a, b, 2014, 2013). The data generated by this work are available at https://doi.org/10.18160/gcp-2019 (Friedlingstein et al., 2019)
The oncogene Gankyrin is expressed in testicular cancer and contributes to cisplatin sensitivity in embryonal carcinoma cells
Recommended from our members
Established and Emerging Strategies for Polymer Chain-End Modification
Recommended from our members
Direct access to functional (Meth)acrylate copolymers through transesterification with lithium alkoxides
A straightforward and efficient synthetic method that transforms poly(methyl methacrylate) (PMMA) into value-added materials is presented. Specifically, PMMA is modified by transesterification to produce a variety of functional copolymers from a single starting material. Key to the reaction is the use of lithium alkoxides, prepared by treatment of primary alcohols with LDA, to displace the methyl esters. Under optimized conditions, up to 65% functionalization was achieved and copolymers containing alkyl, alkene, alkyne, benzyl, and (poly)ether side groups could be prepared. The versatility of this protocol was further demonstrated through the functionalization of both PMMA homo and block copolymers obtained through either radical polymerization (traditional and controlled) or anionic procedures. The scope of this strategy was illustrated by extension to a range of architectures and polymer backbones
Dual-energy X-ray absorptiometry of human metatarsals: Precision, least significant change and association to ex vivo fracture force
Practical chain-end reduction of polymers obtained with ATRP
A practical and user-friendly strategy for the chain-end reduction of halogen terminated polymers that employs hydrogen gas and heterogeneous catalysis (palladium on carbon) is reported. Quantitative dehalogenation of a wide variety of monomer families (polystyrenes, polyacrylates, and polymethacrylates) with either chlorine or bromine chain-ends is observed. The utility of this chain-end reduction is further highlighted by mild reaction conditions, simple purification, and compatibility with a wide range of solvents. (Figure presented.)