735 research outputs found

    Observations of SN2011fe with INTEGRAL

    Full text link
    SN2011fe was detected by the Palomar Transient Factory on August 24th 2011 in M101 few hours after the explosion. From the early spectra it was immediately realized that it was a Type Ia supernova thus making this event the brightest one discovered in the last twenty years. In this paper the observations performed with the instruments on board of INTEGRAL (SPI, IBIS/ISGRI, JEM-X and OMC) before and after the maximum of the optical light as well as the interpretation in terms of the existing models of γ\gamma--ray emission from such kind of supernovae are reported. All INTEGRAL high-energy have only been able to provide upper limits to the expected emission due to the decay of 56^{56}Ni. These bounds allow to reject explosions involving a massive white dwarf in the sub--Chandrasekhar scenario. On the other hand, the optical light curve obtained with the OMC camera suggests that the event was produced by a delayed detonation of a CO white dwarf that produced 0.5\sim 0.5 M\odot of 56^{56}Ni. In this particular case, INTEGRAL would have only been able to detect the early γ\gamma--ray emission if the supernova had occurred at a distance of 2 -3 Mpc, although the brightest event could be visible up to distances larger by a factor two.Comment: Proceedings of "An INTEGRAL view of the high-energy sky (the first 10 years)" the 9th INTEGRAL Workshop, October 15-19, 2012, Paris, France, in Proceedings of Science (INTEGRAL 2012), Eds. A. Goldwurm, F. Lebrun and C. Winkler, http://pos.sissa.it/cgi-bin/reader/conf.cgi?confid=176, id number PoS (INTEGRAL 2012) 103 (2013

    Observation of SN2011fe with INTEGRAL. I. Pre--maximum phase

    Get PDF
    SN2011fe was detected by the Palomar Transient Factory on August 24th 2011 in M101 a few hours after the explosion. From the early optical spectra it was immediately realized that it was a Type Ia supernova thus making this event the brightest one discovered in the last twenty years. The distance of the event offered the rare opportunity to perform a detailed observation with the instruments on board of INTEGRAL to detect the gamma-ray emission expected from the decay chains of 56^{56}Ni. The observations were performed in two runs, one before and around the optical maximum, aimed to detect the early emission from the decay of 56^{56}Ni and another after this maximum aimed to detect the emission of 56^{56}Co. The observations performed with the instruments on board of INTEGRAL (SPI, IBIS/ISGRI, JEMX and OMC) have been analyzed and compared with the existing models of gamma-ray emission from such kind of supernovae. In this paper, the analysis of the gamma-ray emission has been restricted to the first epoch. Both, SPI and IBIS/ISGRI, only provide upper-limits to the expected emission due to the decay of 56^{56}Ni. These upper-limits on the gamma-ray flux are of 7.1 ×\times 105^{-5} ph/s/cm2^2 for the 158 keV line and of 2.3 ×\times 104^{-4} ph/s/cm2^2 for the 812 keV line. These bounds allow to reject at the 2σ2\sigma level explosions involving a massive white dwarf, 1\sim 1 M\odot in the sub--Chandrasekhar scenario and specifically all models that would have substantial amounts of radioactive 56^{56}Ni in the outer layers of the exploding star responsible of the SN2011fe event. The optical light curve obtained with the OMC camera also suggests that SN2011fe was the outcome of the explosion, possibly a delayed detonation although other models are possible, of a CO white dwarf that synthesized 0.55\sim 0.55 M_\odot of 56^{56}Ni. For this specific model.Comment: Accepted for publication in A&A. 10 pages, 10 figure

    First report of Alternaria black spot of pomegranate caused by Alternaria alternata in Spain

    Full text link
    Berbegal, M.; López- Cortés, I.; Salazar Hernández, DM.; Gramaje, D.; Perez-Sierra, A.; Garcia-Jimenez, J.; Armengol, J. (2014). First report of Alternaria black spot of pomegranate caused by Alternaria alternata in Spain. Plant Disease. 98(5):689-689. doi:10.1094/PDIS-07-13-0717-PDNS68968998

    Constraints on the steady and pulsed very high energy gamma-ray emission from observations of PSR B1951+32/CTB 80 with the MAGIC Telescope

    Get PDF
    We report on very high energy gamma-observations with the MAGIC Telescope of the pulsar PSR B1951+32 and its associated nebula, CTB 80. Our data constrain the cutoff energy of the pulsar to be less than 32 GeV, assuming the pulsed gamma-ray emission to be exponentially cut off. The upper limit on the flux of pulsed gamma-ray emission above 75 GeV is 4.3*10^-11 photons cm^-2 sec^-1, and the upper limit on the flux of steady emission above 140 GeV is 1.5*10^-11 photons cm^-2 sec^-1. We discuss our results in the framework of recent model predictions and other studies.Comment: 7 pages, 7 figures, replaced with published versio

    Measurement of the Ge 70 (n,γ) cross section up to 300 keV at the CERN n-TOF facility

    Get PDF
    ©2019 American Physical Society.Neutron capture data on intermediate mass nuclei are of key importance to nucleosynthesis in the weak component of the slow neutron capture processes, which occurs in massive stars. The (n,γ) cross section on Ge70, which is mainly produced in the s process, was measured at the neutron time-of-flight facility n-TOF at CERN. Resonance capture kernels were determined up to 40 keV neutron energy and average cross sections up to 300 keV. Stellar cross sections were calculated from kT=5 keV to kT=100 keV and are in very good agreement with a previous measurement by Walter and Beer (1985) and recent evaluations. Average cross sections are in agreement with Walter and Beer (1985) over most of the neutron energy range covered, while they are systematically smaller for neutron energies above 150 keV. We have calculated isotopic abundances produced in s-process environments in a 25 solar mass star for two initial metallicities (below solar and close to solar). While the low metallicity model reproduces best the solar system germanium isotopic abundances, the close to solar model shows a good global match to solar system abundances in the range of mass numbers A=60-80.Peer reviewedFinal Published versio

    Pre-exposure prophylaxis with hydroxychloroquine for COVID-19 : a double-blind, placebo-controlled randomized clinical trial

    Get PDF
    Background: Pre-exposure prophylaxis (PrEP) is a promising strategy to break COVID-19 transmission. Although hydroxychloroquine was evaluated for treatment and post-exposure prophylaxis, it is not evaluated for COVID-19 PrEP yet. The aim of this study was to evaluate the efficacy and safety of PrEP with hydroxychloroquine against placebo in healthcare workers at high risk of SARS-CoV-2 infection during an epidemic period. Methods: We conducted a double-blind placebo-controlled randomized clinical trial in three hospitals in Barcelona, Spain. From 350 adult healthcare workers screened, we included 269 participants with no active or past SARS-CoV-2 infection (determined by a negative nasopharyngeal SARS-CoV-2 PCR and a negative serology against SARS-CoV-2). Participants allocated in the intervention arm (PrEP) received 400 mg of hydroxychloroquine daily for the first four consecutive days and subsequently, 400 mg weekly during the study period. Participants in the control group followed the same treatment schedule with placebo tablets. Results: 52.8% (142/269) of participants were in the hydroxychloroquine arm and 47.2% (127/269) in the placebo arm. Given the national epidemic incidence decay, only one participant in each group was diagnosed with COVID-19. The trial was stopped due to futility and our study design was deemed underpowered to evaluate any benefit regarding PrEP efficacy. Both groups showed a similar proportion of participants experiencing at least one adverse event (AE) (p=0.548). No serious AEs were reported. Almost all AEs (96.4%, 106/110) were mild. Only mild gastrointestinal symptoms were significantly higher in the hydroxychloroquine arm compared to the placebo arm (27.4% (39/142) vs 15.7% (20/127), p=0.041). Conclusions: Although the efficacy of PrEP with hydroxychloroquine for preventing COVID-19 could not be evaluated, our study showed that PrEP with hydroxychloroquine at low doses is safe. Trial registration: ClinicalTrials.govNCT04331834. Registered on April 2, 2020

    MAGIC upper limits on the very high energy emission from GRBs

    Get PDF
    The fast repositioning system of the MAGIC Telescope has allowed during its first data cycle, between 2005 and the beginning of year 2006, observing nine different GRBs as possible sources of very high energy gammas. These observations were triggered by alerts from Swift, HETE-II, and Integral; they started as fast as possible after the alerts and lasted for several minutes, with an energy threshold varying between 80 and 200 GeV, depending upon the zenith angle of the burst. No evidence for gamma signals was found, and upper limits for the flux were derived for all events, using the standard analysis chain of MAGIC. For the bursts with measured redshift, the upper limits are compatible with a power law extrapolation, when the intrinsic fluxes are evaluated taking into account the attenuation due to the scattering in the Metagalactic Radiation Field (MRF).Comment: 25 pages, 9 figures, final version accepted by ApJ. Changet title to "MAGIC upped limits on the VERY high energy emission from GRBs", re-organized chapter with description of observation, removed non necessaries figures, added plot of effective area depending on zenith angle, added an appendix explaining the upper limit calculation, added some reference

    Discovery of VHE Gamma Radiation from IC443 with the MAGIC Telescope

    Get PDF
    We report the detection of a new source of very high energy (VHE, E_gamma >= 100GeV) gamma-ray emission located close to the Galactic Plane, MAGIC J0616+225, which is spatially coincident with SNR IC443. The observations were carried out with the MAGIC telescope in the periods December 2005 - January 2006 and December 2006 - January 2007. Here we present results from this source, leading to a VHE gamma-ray signal with a statistical significance of 5.7 sigma in the 2006/7 data and a measured differential gamma-ray flux consistent with a power law, described as dN_gamma/(dA dt dE) = (1.0 +/- 0.2)*10^(-11)(E/0.4 TeV)^(-3.1 +/- 0.3) cm^(-2)s^(-1)TeV^(-1). We briefly discuss the observational technique used and the procedure implemented for the data analysis. The results are put in the perspective of the multiwavelength emission and the molecular environment found in the region of IC443.Comment: Accepted by ApJ Letter

    Differential body composition effects of protease inhibitors recommended for initial treatment of HIV infection: A randomized clinical trial

    Full text link
    This article has been accepted for publication in Clinical Infectious Diseases ©2014 The Authors .Published by Oxford University Press on Clinical Infectious Disease 60.5. DOI: 10.1093/cid/ciu898Background. It is unclear whether metabolic or body composition effects may differ between protease inhibitor-based regimens recommended for initial treatment of HIV infection. Methods. ATADAR is a phase IV, open-label, multicenter randomized clinical trial. Stable antiretroviral-naive HIV-infected adults were randomly assigned to atazanavir/ritonavir 300/100 mg or darunavir/ritonavir 800/100 mg in combination with tenofovir/emtricitabine daily. Pre-defined end-points were treatment or virological failure, drug discontinuation due to adverse effects, and laboratory and body composition changes at 96 weeks. Results. At 96 weeks, 56 (62%) atazanavir/ritonavir and 62 (71%) darunavir/ritonavir patients remained free of treatment failure (estimated difference 8.2%; 95%CI -0.6 to 21.6); and 71 (79%) atazanavir/ritonavir and 75 (85%) darunavir/ritonavir patients remained free of virological failure (estimated difference 6.3%; 95%CI -0.5 to 17.6). Seven vs. five patients discontinued atazanavir/ritonavir or darunavir/ritonavir due to adverse effects. Total and HDL cholesterol similarly increased in both arms, but triglycerides increased more in atazanavir/ritonavir arm. At 96 weeks, body fat (estimated difference 2862.2 gr; 95%CI 726.7 to 4997.7; P=0.0090), limb fat (estimated difference 1403.3 gr; 95%CI 388.4 to 2418.2; P=0.0071), and subcutaneous abdominal adipose tissue (estimated difference 28.4 cm2; 95%CI 1.9 to 55.0; P=0.0362) increased more in atazanavir/ritonavir than in darunavir/ritonavir arm. Body fat changes in atazanavir/ritonavir arm were associated with higher insulin resistance. Conclusions. We found no major differences between atazanavir/ritonavir and darunavir/ritonavir in efficacy, clinically-relevant side effects, or plasma cholesterol fractions. However, atazanavir/ritonavir led to higher triglycerides and total and subcutaneous fat than darunavir/ritonavir and fat gains with atazanavir/ritonavir were associated with insulin resistanceThis is an Investigator Sponsored Research study. It was supported in part by research grants from Bristol‐Myers Squibb and Janssen‐Cilag; Instituto de Salud Carlos III (PI12/01217) and Red Temática Cooperativa de Investigación en SIDA G03/173 (RIS‐EST11), Ministerio de Ciencia e Innovación, Spain. (Registration number: NCT01274780; registry name: ATADAR; EUDRACT; 2010‐021002‐38)
    corecore