192 research outputs found

    A cohort study of post-weaning multisystemic wasting syndrome and PCV2 in 178 pigs from birth to 14 weeks on a single farm in England

    Get PDF
    Our hypothesis was that pigs that develop post-weaning multisystemic wasting syndrome (PMWS) are detectable from an early age with signs of weight loss and other clinical and serological abnormalities. Therefore, the objective of this study was to investigate the temporally varying and fixed events linked with the clinical incidence of PMWS by comparing affected and unaffected pigs in a cohort of 178 male piglets. Piglets were enrolled at birth and examined each week. Samples of blood were collected at regular intervals. The exposures measured were porcine circovirus type 2 (PCV2) antibody titres in all 178 and PCV2 antigen in a subset of 75 piglets. We also observed piglet health and measured their weight, and a post-mortem examination was performed by an external laboratory on all pigs between 6 and 14 weeks of age that died. From the cohort, 14 (8%) pigs died from PMWS and 4% from other causes. A further 37 pigs between 6 and 14 weeks of age died from PMWS (30) and ileitis and other causes (7). PMWS was only apparent in pigs from 1 to 2 weeks before death when they wasted rapidly. There were no other characteristic clinical signs and no obvious gross clinical lesions post-mortem. There was no strong link with PCV2 antibody throughout life but PCV2 antigen level was higher from 4 to 6 weeks of age in pigs that died from PMWS compared with pigs that died from other causes

    Referral for specialist follow-up and its association with post-discharge mortality among patients with systolic heart failure (from the National Heart Failure Audit for England and Wales)

    Get PDF
    For patients admitted with worsening heart failure, early follow-up after discharge is recommended. Whether outcomes can be improved when follow-up is done by cardiologists is uncertain. We aimed to determine the association between cardiology follow-up and risk of death for patients with heart failure discharged from hospital. Using data from the National Heart Failure Audit (England & Wales), we investigated the effect of referral to cardiology follow-up on 30-day and one-year mortality in 68 772 patients with heart failure and a reduced left ventricular ejection fraction (HFREF) discharged from 185 hospitals between 2007 to 2013. The primary analyses used instrumental variable analysis complemented by hierarchical logistic and propensity matched models. At the hospital level, rates of referral to cardiologists varied from 6% to 96%. The median odds ratio (OR) for referral to cardiologist was 2.3 (95% confidence interval [CI] 2.1, 2.5), suggesting that, on average, the odds of a patient being referred for cardiologist follow-up after discharge differed approximately 2.3 times from one randomly selected hospital to another one. Based on the proportion of patients (per region) referred for cardiology follow-up, referral for cardiology follow-up was associated with lower 30-day (OR 0.70; CI 0.55, 0.89) and one-year mortality (OR 0.81; CI 0.68, 0.95) compared with no plans for cardiology follow-up (i.e., standard follow-up done by family doctors). Results from hierarchical logistic models and propensity matched models were consistent (30-day mortality OR 0.66; CI 0.61, 0.72 and 0.66; CI 0.58, 0.76 for hierarchical and propensity matched models, respectively). For patients with HFREF admitted to hospital with worsening symptoms, referral to cardiology services for follow-up after discharge is strongly associated with reduced mortality, both early and late

    Myocardial injury in severe COVID-19 infection

    Get PDF
    No abstract available

    Correlations in Intermediate Energy Two-Proton Removal Reactions

    Get PDF
    We report final-state-exclusive measurements of the light charged fragments in coincidence with Ne26 residual nuclei following the direct two-proton removal from a neutron-rich Mg28 secondary beam. A Dalitz-plot analysis and comparisons with simulations show that a majority of the triple-coincidence events with two protons display phase-space correlations consistent with the (two-body) kinematics of a spatially correlated pair-removal mechanism. The fraction of such correlated events, 56(12)%, is consistent with the fraction of the calculated cross section, 64%, arising from spin S=0 two-proton configurations in the entrance-channel (shell-model) Mg28 ground state wave function. This result promises access to an additional and more specific probe of the spin and spatial correlations of valence nucleon pairs in exotic nuclei produced as fast secondary beams. � 2012 American Physical Society

    Planck intermediate results: IV. the XMM-Newton validation programme for new Planck galaxy clusters

    Get PDF

    Standards in semen examination:publishing reproducible and reliable data based on high-quality methodology

    Get PDF
    Biomedical science is rapidly developing in terms of more transparency, openness and reproducibility of scientific publications. This is even more important for all studies that are based on results from basic semen examination. Recently two concordant documents have been published: the 6th edition of the WHO Laboratory Manual for the Examination and Processing of Human Semen, and the International Standard ISO 23162:2021. With these tools, we propose that authors should be instructed to follow these laboratory methods in order to publish studies in peer-reviewed journals, preferable by using a checklist as suggested in an Appendix to this article.Peer reviewe

    Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

    Get PDF
    The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR

    On the mechanisms governing gas penetration into a tokamak plasma during a massive gas injection

    Get PDF
    A new 1D radial fluid code, IMAGINE, is used to simulate the penetration of gas into a tokamak plasma during a massive gas injection (MGI). The main result is that the gas is in general strongly braked as it reaches the plasma, due to mechanisms related to charge exchange and (to a smaller extent) recombination. As a result, only a fraction of the gas penetrates into the plasma. Also, a shock wave is created in the gas which propagates away from the plasma, braking and compressing the incoming gas. Simulation results are quantitatively consistent, at least in terms of orders of magnitude, with experimental data for a D 2 MGI into a JET Ohmic plasma. Simulations of MGI into the background plasma surrounding a runaway electron beam show that if the background electron density is too high, the gas may not penetrate, suggesting a possible explanation for the recent results of Reux et al in JET (2015 Nucl. Fusion 55 093013)

    Relationship of edge localized mode burst times with divertor flux loop signal phase in JET

    Get PDF
    A phase relationship is identified between sequential edge localized modes (ELMs) occurrence times in a set of H-mode tokamak plasmas to the voltage measured in full flux azimuthal loops in the divertor region. We focus on plasmas in the Joint European Torus where a steady H-mode is sustained over several seconds, during which ELMs are observed in the Be II emission at the divertor. The ELMs analysed arise from intrinsic ELMing, in that there is no deliberate intent to control the ELMing process by external means. We use ELM timings derived from the Be II signal to perform direct time domain analysis of the full flux loop VLD2 and VLD3 signals, which provide a high cadence global measurement proportional to the voltage induced by changes in poloidal magnetic flux. Specifically, we examine how the time interval between pairs of successive ELMs is linked to the time-evolving phase of the full flux loop signals. Each ELM produces a clear early pulse in the full flux loop signals, whose peak time is used to condition our analysis. The arrival time of the following ELM, relative to this pulse, is found to fall into one of two categories: (i) prompt ELMs, which are directly paced by the initial response seen in the flux loop signals; and (ii) all other ELMs, which occur after the initial response of the full flux loop signals has decayed in amplitude. The times at which ELMs in category (ii) occur, relative to the first ELM of the pair, are clustered at times when the instantaneous phase of the full flux loop signal is close to its value at the time of the first ELM
    corecore