59 research outputs found

    In vivo detection of teriflunomide-derived fluorine signal during neuroinflammation using fluorine MR spectroscopy

    Get PDF
    BACKGROUND: Magnetic resonance imaging (MRI) is indispensable for diagnosing neurological conditions such as multiple sclerosis (MS). MRI also supports decisions regarding the choice of disease-modifying drugs (DMDs). Determining in vivo tissue concentrations of DMDs has the potential to become an essential clinical tool for therapeutic drug monitoring (TDM). The aim here was to examine the feasibility of fluorine-19 ((19)F) MR methods to detect the fluorinated DMD teriflunomide (TF) during normal and pathological conditions. METHODS: We used (19)F MR spectroscopy to detect TF in the experimental autoimmune encephalomyelitis (EAE) mouse model of multiple sclerosis (MS) in vivo. Prior to the in vivo investigations we characterized the MR properties of TF in vitro. We studied the impact of pH and protein binding as well as MR contrast agents. RESULTS: We could detect TF in vivo and could follow the (19)F MR signal over different time points of disease. We quantified TF concentrations in different tissues using HPLC/MS and showed a significant correlation between ex vivo TF levels in serum and the ex vivo (19)F MR signal. CONCLUSION: This study demonstrates the feasibility of (19)F MR methods to detect TF during neuroinflammation in vivo. It also highlights the need for further technological developments in this field. The ultimate goal is to add (19)F MR protocols to conventional (1)H MRI protocols in clinical practice to guide therapy decisions

    Color perception deficits in co-existing attention-deficit/hyperactivity disorder and chronic tic disorders

    Get PDF
    Preliminary findings suggest that color perception, particularly of blue-yellow stimuli, is impaired in attention-deficit/hyperactivity disorder (ADHD) as well as in chronic tic disorders (CTD). However, these findings have been not replicated and it is unclear what these deficits mean for the comorbidity of ADHD + CTD. Four groups (ADHD, CTD, ADHD + CTD, controls) of children with similar age, IQ and gender distribution were investigated with the Farnsworth-Munsell 100 Hue Test (FMT) and the Stroop-Color-Word Task using a factorial design. Color perception deficits, as indexed by the FMT, were found for both main factors (ADHD and CTD), but there were no interaction effects. A preponderance of deficits on the blue-yellow compared to the red-green axis was detected for ADHD. In the Stroop task only the 'pure' ADHD group showed impairments in interference control and other parameters of Stroop performance. No significant correlations between any FMT parameter and color naming in the Stroop task were found. Basic color perception deficits in both ADHD and CTD could be found. Beyond that, it could be shown that these deficits are additive in the case of comorbidity (ADHD + CTD). Performance deficits on the Stroop task were present only in the 'pure' ADHD group. Hence, the latter may be compensated in the comorbid group by good prefrontal capabilities of CTD. The influence of color perception deficits on Stroop task performance might be negligible. © 2007 Springer-Verlag

    NMR and dielectric studies of hydrated collagen and elastin: Evidence for a delocalized secondary relaxation

    Full text link
    Using a combination of dielectric spectroscopy and solid-state deuteron NMR, the hydration water dynamics of connective tissue proteins is studied at sub-ambient temperatures. In this range, the water dynamics follows an Arrhenius law. A scaling analysis of dielectric losses, 'two-phase' NMR spectra, and spin-lattice relaxation times consistently yield evidence for a Gaussian distribution of energy barriers. With the dielectric data as input, random-walk simulations of a large-angle, quasi-isotropic water reorientation provide an approximate description of stimulated-echo data on hydrated elastin. This secondary process takes place in an essentially rigid energy landscape, but in contrast to typical {\beta}-relaxations it is quasi-isotropic and delocalized. The delocalization is inferred from previous NMR diffusometry experiments. To emphasize the distinction from conventional {\beta}-processes, for aqueous systems such a matrix-decoupled relaxation was termed a {\nu}-process. It is emphasized that the phenomenology of this time-honored, 'new' process is shared by many non-aqueous binary glasses in which the constituent components exhibit a sufficient dynamical contrast

    Pentafluorosulfanyl (SF(5)) as a superior (19)F magnetic resonance reporter group: signal detection and biological activity of teriflunomide derivatives

    Get PDF
    Fluorine ((19)F) magnetic resonance imaging (MRI) is severely limited by a low signal-to noise ratio (SNR), and tapping it for (19)F drug detection in vivo still poses a significant challenge. However, it bears the potential for label-free theranostic imaging. Recently, we detected the fluorinated dihydroorotate dehydrogenase (DHODH) inhibitor teriflunomide (TF) noninvasively in an animal model of multiple sclerosis (MS) using (19)F MR spectroscopy (MRS). In the present study, we probed distinct modifications to the CF(3) group of TF to improve its SNR. This revealed SF(5) as a superior alternative to the CF(3) group. The value of the SF(5) bioisostere as a (19)F MRI reporter group within a biological or pharmacological context is by far underexplored. Here, we compared the biological and pharmacological activities of different TF derivatives and their (19)F MR properties (chemical shift and relaxation times). The (19)F MR SNR efficiency of three MRI methods revealed that SF(5)-substituted TF has the highest (19)F MR SNR efficiency in combination with an ultrashort echo-time (UTE) MRI method. Chemical modifications did not reduce pharmacological or biological activity as shown in the in vitro dihydroorotate dehydrogenase enzyme and T cell proliferation assays. Instead, SF(5)-substituted TF showed an improved capacity to inhibit T cell proliferation, indicating better anti-inflammatory activity and its suitability as a viable bioisostere in this context. This study proposes SF(5) as a novel superior (19)F MR reporter group for the MS drug teriflunomide

    Non-Water-Suppressed 1H MR Spectroscopy with Orientational Prior Knowledge Shows Potential for Separating Intra- and Extramyocellular Lipid Signals in Human Myocardium

    Get PDF
    Conditions such as type II diabetes are linked with elevated lipid levels in the heart, and significantly increased risk of heart failure; however, metabolic processes underlying the development of cardiac disease in type II diabetes are not fully understood. Here we present a non-invasive method for in vivo investigation of cardiac lipid metabolism: namely, IVS-McPRESS. This technique uses metabolite-cycled, non-water suppressed 1H cardiac magnetic resonance spectroscopy with prospective and retrospective motion correction. High-quality IVS-McPRESS data acquired from healthy volunteers allowed us to investigate the frequency shift of extramyocellular lipid signals, which depends on the myocardial fibre orientation. Assuming consistent voxel positioning relative to myofibres, the myofibre angle with the magnetic field was derived from the voxel orientation. For separation and individual analysis of intra- and extramyocellular lipid signals, the angle myocardial fibres in the spectroscopy voxel take with the magnetic field should be within ±24.5°. Metabolite and lipid concentrations were analysed with respect to BMI. Significant correlations between BMI and unsaturated fatty acids in intramyocellular lipids, and methylene groups in extramyocellular lipids were found. The proposed IVS-McPRESS technique enables non-invasive investigation of cardiac lipid metabolism and may thus be a useful tool to study healthy and pathological conditions

    Towards accurate and precise T1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions

    Get PDF
    Mapping of the longitudinal relaxation time (T1) and extracellular volume (ECV) offers a means of identifying pathological changes in myocardial tissue, including diffuse changes that may be invisible to existing T1-weighted methods. This technique has recently shown strong clinical utility for pathologies such as Anderson- Fabry disease and amyloidosis and has generated clinical interest as a possible means of detecting small changes in diffuse fibrosis; however, scatter in T1 and ECV estimates offers challenges for detecting these changes, and bias limits comparisons between sites and vendors. There are several technical and physiological pitfalls that influence the accuracy (bias) and precision (repeatability) of T1 and ECV mapping methods. The goal of this review is to describe the most significant of these, and detail current solutions, in order to aid scientists and clinicians to maximise the utility of T1 mapping in their clinical or research setting. A detailed summary of technical and physiological factors, issues relating to contrast agents, and specific disease-related issues is provided, along with some considerations on the future directions of the field. Towards accurate and precise T1 and extracellular volume mapping in the myocardium: a guide to current pitfalls and their solutions. Available from: https://www.researchgate.net/publication/317548806_Towards_accurate_and_precise_T1_and_extracellular_volume_mapping_in_the_myocardium_a_guide_to_current_pitfalls_and_their_solutions [accessed Jun 13, 2017]

    Frequency drift in MR spectroscopy at 3T

    Get PDF
    Purpose: Heating of gradient coils and passive shim components is a common cause of instability in the B-0 field, especially when gradient intensive sequences are used. The aim of the study was to set a benchmark for typical drift encountered during MR spectroscopy (MRS) to assess the need for real-time field-frequency locking on MRI scanners by comparing field drift data from a large number of sites.Method: A standardized protocol was developed for 80 participating sites using 99 3T MR scanners from 3 major vendors. Phantom water signals were acquired before and after an EPI sequence. The protocol consisted of: minimal preparatory imaging; a short pre-fMRI PRESS; a ten-minute fMRI acquisition; and a long post-fMRI PRESS acquisition. Both pre- and post-fMRI PRESS were non-water suppressed. Real-time frequency stabilization/adjustment was switched off when appropriate. Sixty scanners repeated the protocol for a second dataset. In addition, a three-hour post-fMRI MRS acquisition was performed at one site to observe change of gradient temperature and drift rate. Spectral analysis was performed using MATLAB. Frequency drift in pre-fMRI PRESS data were compared with the first 5:20 minutes and the full 30:00 minutes of data after fMRI. Median (interquartile range) drifts were measured and showed in violin plot. Paired t-tests were performed to compare frequency drift pre- and post-fMRI. A simulated in vivo spectrum was generated using FID-A to visualize the effect of the observed frequency drifts. The simulated spectrum was convolved with the frequency trace for the most extreme cases. Impacts of frequency drifts on NAA and GABA were also simulated as a function of linear drift. Data from the repeated protocol were compared with the corresponding first dataset using Pearson's and intraclass correlation coefficients (ICC).Results: Of the data collected from 99 scanners, 4 were excluded due to various reasons. Thus, data from 95 scanners were ultimately analyzed. For the first 5:20 min (64 transients), median (interquartile range) drift was 0.44 (1.29) Hz before fMRI and 0.83 (1.29) Hz after. This increased to 3.15 (4.02) Hz for the full 30 min (360 transients) run. Average drift rates were 0.29 Hz/min before fMRI and 0.43 Hz/min after. Paired t-tests indicated that drift increased after fMRI, as expected (p &lt; 0.05). Simulated spectra convolved with the frequency drift showed that the intensity of the NAA singlet was reduced by up to 26%, 44 % and 18% for GE, Philips and Siemens scanners after fMRI, respectively. ICCs indicated good agreement between datasets acquired on separate days. The single site long acquisition showed drift rate was reduced to 0.03 Hz/min approximately three hours after fMRI.Discussion: This study analyzed frequency drift data from 95 3T MRI scanners. Median levels of drift were relatively low (5-min average under 1 Hz), but the most extreme cases suffered from higher levels of drift. The extent of drift varied across scanners which both linear and nonlinear drifts were observed.</p

    The genetic architecture of the human cerebral cortex

    Get PDF
    The cerebral cortex underlies our complex cognitive capabilities, yet little is known about the specific genetic loci that influence human cortical structure. To identify genetic variants that affect cortical structure, we conducted a genome-wide association meta-analysis of brain magnetic resonance imaging data from 51,665 individuals. We analyzed the surface area and average thickness of the whole cortex and 34 regions with known functional specializations. We identified 199 significant loci and found significant enrichment for loci influencing total surface area within regulatory elements that are active during prenatal cortical development, supporting the radial unit hypothesis. Loci that affect regional surface area cluster near genes in Wnt signaling pathways, which influence progenitor expansion and areal identity. Variation in cortical structure is genetically correlated with cognitive function, Parkinson's disease, insomnia, depression, neuroticism, and attention deficit hyperactivity disorder

    Requirements for Optimal B0 Shimming for a Spectroscopy Voxel in the Frontal Cortex at Ultra-High Fields

    No full text
    The transition of Magnetic Resonance Spectroscopy to ultra-high fields promises major advantages with respect to SNR and spectral resolution. In order to gain meaningful results, excellent B0 shimming is of outermost importance. Naturally, the amplitudes of the shim fields are limited by hardware specifications. However, an optimal B0 inhomogeneity compensation might not be possible within these hardware constraints, especially for regions with large inhomogeneities, such as the frontal cortex. This work investigates the hardware requirements for optimal B0 inhomogeneity compensation and the effect of shim hardware constraints on B0 shimming for a spectroscopy voxel in the frontal cortex
    corecore