89 research outputs found

    THE ARGOMARINE PROJECT: A LOW COST PLATFORM TO INTEGRATE DATA AND THE EXPLORATORY USE OF NEW TOOLS IN MONITORING OIL SPILL

    Get PDF
    One of the key aim of ARGOMARINE focuses on the development of a platform to integrate different maritime data (such as metoceanographic data, transport data, pollution data, etc). Major national organizations such as Navies and Coast Guards are aiming to integrate different types of information to define a maritime picture on a wide scale. This entails developing complex, expensive and classified "hubs" to collect, store, analyze and disseminate the maritime data. ARGOMARINE plans to develop a Marine Information System (MIS), a connected group of ICT subsystems performing data storage, mining and analysis, decision-support, as well as a web-GIS portal for the access and usage of the products and services released to System Managers and end-users. MIS will integrate remote sensing data, field experiment results, forecast models with tools for data storage and retrieval, data manipulation, analysis and presentation; all these features will be accessible through a common interface. Operationally, the following sub-systems have been confirmed for the MIS platform: SAR (Synthetic Aperture Radar) image processing, hyperspectral-thermal image analysis, mathematical simulation for forecast models, dynamic risk maps management, Autonomous Underwater Vehicle (AUV) management and data analysis, marine traffic monitoring through Automatic Identification System (AIS), Environmental Decision Support (EDS), and data mining/warehousing through operational and historical databases. Data integration of all data from these different systems is an innovative approach to maritime surveillance.JRC.G.4-Maritime affair

    The space gamma-ray observatory AGILE

    Get PDF
    Abstract Gamma-rays of cosmic origin are a manifestation of the most energetic phenomena in our Universe. Many astrophysical sources emit gamma-rays including relativistic compact stars, massive black holes in active galactic nuclei, gamma-ray burst sources, and our Sun during intense flares. The mission AGILE ( Astro-rivelatore Gamma a Immagini LEggero ) is an innovative, cost effective gamma ray mission selected by the Italian Space Agency (ASI) as first payload of the Program for Small Scientific Missions. It is designed to detect and image gamma-ray sources in the energy range 30 MeV-50 GeV and operate as an Observatory open to the international community. Primary scientific goals include the study of AGN's, gamma ray bursts, Galactic sources, unidentified gamma ray sources, solar flares and diffuse gamma ray emission. AGILE is planned to be operational during the years 2002–2005. It will an ideal 'bridge' between EGRET and GLAST, and support space observations and ground based multiwavelength studies of high energy sources

    AGILE TGFS AND GLOBAL LIGHTNING ACTIVITY

    Get PDF
    [1] The AGILE satellite detects Terrestrial Gamma-ray Flashes (TGFs) in the 0.35–100 MeV energy range using its Mini-Calorimeter (MCAL) instrument with an average detection rate of 10 TGFs/month. Thanks to its Low Earth Orbit with only 2.5 degree of inclination, AGILE guarantees an unprecedented exposure above the equator, where both lightning activity and TGF detection peak. Here we report the comparison between the AGILE TGFs detected between March 2009 and February 2010 and full climatology lightning worldwide distribution based on satellite optical observations from LIS (Lightning Imaging Sensor) and OTD (Optical Transient Detector) instruments. This approach is complementary to the one-to-one TGF/lightning correlations by ground-based sferics measurements. Based on mono and bi-dimensional Kolmogorov-Smirnov tests, we show that the AGILE TGFs and time-averaged global lightning in the equatorial area are not drawn from the same distribution. However, we find significant regional differences in the degree of correlation as well as in the TGF/lightning ratio. In the case of south east Asia we find a 87% probability for the TGF and lightning being samples of the same distribution. This result supports the idea that the physical conditions at play in TGF generation can have strong geographical and climatological modulation. Based on the assumption that the observed range of TGF/flash ratio holds at all latitudes we can estimate a global rate of ≃ 220 ÷ 570 TGFs per day. The observed TGF/flash geographical modulation as well as the TGF global rate estimate are in agreement with previous observations

    The AGILE Mission

    Get PDF
    AGILE is an Italian Space Agency mission dedicated to observing the gamma-ray Universe. The AGILE's very innovative instrumentation for the first time combines a gamma-ray imager (sensitive in the energy range 30 MeV-50 GeV), a hard X-ray imager (sensitive in the range 18-60 keV), a calorimeter (sensitive in the range 350 keV-100 MeV), and an anticoincidence system. AGILE was successfully launched on 2007 April 23 from the Indian base of Sriharikota and was inserted in an equatorial orbit with very low particle background. Aims. AGILE provides crucial data for the study of active galactic nuclei, gamma-ray bursts, pulsars, unidentified gamma-ray sources, galactic compact objects, supernova remnants, TeV sources, and fundamental physics by microsecond timing. Methods. An optimal sky angular positioning (reaching 0.1 degrees in gamma- rays and 1-2 arcmin in hard X-rays) and very large fields of view (2.5 sr and 1 sr, respectively) are obtained by the use of Silicon detectors integrated in a very compact instrument. Results. AGILE surveyed the gamma- ray sky and detected many Galactic and extragalactic sources during the first months of observations. Particular emphasis is given to multifrequency observation programs of extragalactic and galactic objects. Conclusions. AGILE is a successful high-energy gamma-ray mission that reached its nominal scientific performance. The AGILE Cycle-1 pointing program started on 2007 December 1, and is open to the international community through a Guest Observer Program

    Measurement of isotopic separation of argon with the prototype of the cryogenic distillation plant Aria for dark matter searches

    Get PDF
    The Aria cryogenic distillation plant, located in Sardinia, Italy, is a key component of the DarkSide-20k experimental program for WIMP dark matter searches at the INFN Laboratori Nazionali del Gran Sasso, Italy. Aria is designed to purify the argon, extracted from underground wells in Colorado, USA, and used as the DarkSide-20k target material, to detector-grade quality. In this paper, we report the first measurement of argon isotopic separation by distillation with the 26 m tall Aria prototype. We discuss the measurement of the operating parameters of the column and the observation of the simultaneous separation of the three stable argon isotopes: 36Ar , 38Ar , and 40Ar . We also provide a detailed comparison of the experimental results with commercial process simulation software. This measurement of isotopic separation of argon is a significant achievement for the project, building on the success of the initial demonstration of isotopic separation of nitrogen using the same equipment in 2019

    Association of kidney disease measures with risk of renal function worsening in patients with type 1 diabetes

    Get PDF
    Background: Albuminuria has been classically considered a marker of kidney damage progression in diabetic patients and it is routinely assessed to monitor kidney function. However, the role of a mild GFR reduction on the development of stage 653 CKD has been less explored in type 1 diabetes mellitus (T1DM) patients. Aim of the present study was to evaluate the prognostic role of kidney disease measures, namely albuminuria and reduced GFR, on the development of stage 653 CKD in a large cohort of patients affected by T1DM. Methods: A total of 4284 patients affected by T1DM followed-up at 76 diabetes centers participating to the Italian Association of Clinical Diabetologists (Associazione Medici Diabetologi, AMD) initiative constitutes the study population. Urinary albumin excretion (ACR) and estimated GFR (eGFR) were retrieved and analyzed. The incidence of stage 653 CKD (eGFR < 60 mL/min/1.73 m2) or eGFR reduction > 30% from baseline was evaluated. Results: The mean estimated GFR was 98 \ub1 17 mL/min/1.73m2 and the proportion of patients with albuminuria was 15.3% (n = 654) at baseline. About 8% (n = 337) of patients developed one of the two renal endpoints during the 4-year follow-up period. Age, albuminuria (micro or macro) and baseline eGFR < 90 ml/min/m2 were independent risk factors for stage 653 CKD and renal function worsening. When compared to patients with eGFR > 90 ml/min/1.73m2 and normoalbuminuria, those with albuminuria at baseline had a 1.69 greater risk of reaching stage 3 CKD, while patients with mild eGFR reduction (i.e. eGFR between 90 and 60 mL/min/1.73 m2) show a 3.81 greater risk that rose to 8.24 for those patients with albuminuria and mild eGFR reduction at baseline. Conclusions: Albuminuria and eGFR reduction represent independent risk factors for incident stage 653 CKD in T1DM patients. The simultaneous occurrence of reduced eGFR and albuminuria have a synergistic effect on renal function worsening

    DMTs and Covid-19 severity in MS: a pooled analysis from Italy and France

    Get PDF
    We evaluated the effect of DMTs on Covid-19 severity in patients with MS, with a pooled-analysis of two large cohorts from Italy and France. The association of baseline characteristics and DMTs with Covid-19 severity was assessed by multivariate ordinal-logistic models and pooled by a fixed-effect meta-analysis. 1066 patients with MS from Italy and 721 from France were included. In the multivariate model, anti-CD20 therapies were significantly associated (OR = 2.05, 95%CI = 1.39–3.02, p < 0.001) with Covid-19 severity, whereas interferon indicated a decreased risk (OR = 0.42, 95%CI = 0.18–0.99, p = 0.047). This pooled-analysis confirms an increased risk of severe Covid-19 in patients on anti-CD20 therapies and supports the protective role of interferon

    Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

    Get PDF
    Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a β emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly γ-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector

    SiPM-matrix readout of two-phase argon detectors using electroluminescence in the visible and near infrared range

    Get PDF
    Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter searches to record (in the gas phase) the ionization signal induced by particle scattering in the liquid phase. The “standard” EL mechanism is considered to be due to noble gas excimer emission in the vacuum ultraviolet (VUV). In addition, there are two alternative mechanisms, producing light in the visible and near infrared (NIR) ranges. The first is due to bremsstrahlung of electrons scattered on neutral atoms (“neutral bremsstrahlung”, NBrS). The second, responsible for electron avalanche scintillation in the NIR at higher electric fields, is due to transitions between excited atomic states. In this work, we have for the first time demonstrated two alternative techniques of the optical readout of two-phase argon detectors, in the visible and NIR range, using a silicon photomultiplier matrix and electroluminescence due to either neutral bremsstrahlung or avalanche scintillation. The amplitude yield and position resolution were measured for these readout techniques, which allowed to assess the detection threshold for electron and nuclear recoils in two-phase argon detectors for dark matter searches. To the best of our knowledge, this is the first practical application of the NBrS effect in detection science
    corecore