7 research outputs found

    Evaluation of a robotic technique for transrectal MRI-guided prostate biopsies

    Get PDF
    Item does not contain fulltextOBJECTIVES: To evaluate the accuracy and speed of a novel robotic technique as an aid to perform magnetic resonance image (MRI)-guided prostate biopsies on patients with cancer suspicious regions. METHODS: A pneumatic controlled MR-compatible manipulator with 5 degrees of freedom was developed in-house to guide biopsies under real-time imaging. From 13 consecutive biopsy procedures, the targeting error, biopsy error and target displacement were calculated to evaluate the accuracy. The time was recorded to evaluate manipulation and procedure time. RESULTS: The robotic and manual techniques demonstrated comparable results regarding mean targeting error (5.7 vs 5.8 mm, respectively) and mean target displacement (6.6 vs 6.0 mm, respectively). The mean biopsy error was larger (6.5 vs 4.4 mm) when using the robotic technique, although not significant. Mean procedure and manipulation time were 76 min and 6 min, respectively using the robotic technique and 61 and 8 min with the manual technique. CONCLUSIONS: Although comparable results regarding accuracy and speed were found, the extended technical effort of the robotic technique make the manual technique - currently - more suitable to perform MRI-guided biopsies. Furthermore, this study provided a better insight in displacement of the target during in vivo biopsy procedures.01 februari 201

    Comparing algorithms for automated vessel segmentation in computed tomography scans of the lung: the VESSEL12 study

    Full text link
    The VESSEL12 (VESsel SEgmentation in the Lung) challenge objectively compares the performance of different algorithms to identify vessels in thoracic computed tomography (CT) scans. Vessel segmentation is fundamental in computer aided processing of data generated by 3D imaging modalities. As manual vessel segmentation is prohibitively time consuming, any real world application requires some form of automation. Several approaches exist for automated vessel segmentation, but judging their relative merits is difficult due to a lack of standardized evaluation. We present an annotated reference dataset containing 20 CT scans and propose nine categories to perform a comprehensive evaluation of vessel segmentation algorithms from both academia and industry. Twenty algorithms participated in the VESSEL12 challenge, held at International Symposium on Biomedical Imaging (ISBI) 2012. All results have been published at the VESSEL12 website http://vessel12.grand-challenge.org. The challenge remains ongoing and open to new participants. Our three contributions are: (1) an annotated reference dataset available online for evaluation of new algorithms; (2) a quantitative scoring system for objective comparison of algorithms; and (3) performance analysis of the strengths and weaknesses of the various vessel segmentation methods in the presence of various lung diseases.Rudyanto, RD.; Kerkstra, S.; Van Rikxoort, EM.; Fetita, C.; Brillet, P.; Lefevre, C.; Xue, W.... (2014). Comparing algorithms for automated vessel segmentation in computed tomography scans of the lung: the VESSEL12 study. Medical Image Analysis. 18(7):1217-1232. doi:10.1016/j.media.2014.07.003S1217123218

    Nurse-Led Medicines' Monitoring for Patients with Dementia in Care Homes: A Pragmatic Cohort Stepped Wedge Cluster Randomised Trial

    Get PDF
    People with dementia are susceptible to adverse drug reactions (ADRs). However, they are not always closely monitored for potential problems relating to their medicines: structured nurse-led ADR Profiles have the potential to address this care gap. We aimed to assess the number and nature of clinical problems identified and addressed and changes in prescribing following introduction of nurse-led medicines' monitoring.Pragmatic cohort stepped-wedge cluster Randomised Controlled Trial (RCT) of structured nurse-led medicines' monitoring versus usual care.Five UK private sector care homes.41 service users, taking at least one antipsychotic, antidepressant or anti-epileptic medicine.Nurses completed the West Wales ADR (WWADR) Profile for Mental Health Medicines with each participant according to trial step.Problems addressed and changes in medicines prescribed.Information was collected from participants' notes before randomisation and after each of five monthly trial steps. The impact of the Profile on problems found, actions taken and reduction in mental health medicines was explored in multivariate analyses, accounting for data collection step and site.Five of 10 sites and 43 of 49 service users approached participated. Profile administration increased the number of problems addressed from a mean of 6.02 [SD 2.92] to 9.86 [4.48], effect size 3.84, 95% CI 2.57-4.11, P <0.001. For example, pain was more likely to be treated (adjusted Odds Ratio [aOR] 3.84, 1.78-8.30), and more patients attended dentists and opticians (aOR 52.76 [11.80-235.90] and 5.12 [1.45-18.03] respectively). Profile use was associated with reduction in mental health medicines (aOR 4.45, 1.15-17.22).The WWADR Profile for Mental Health Medicines can improve the quality and safety of care, and warrants further investigation as a strategy to mitigate the known adverse effects of prescribed medicines.ISRCTN 48133332

    Normal pediatric postmortem CT appearances

    No full text
    Postmortem radiology is a rapidly developing specialty that is increasingly used as an adjunct to or substitute for conventional autopsy. The goal is to find patterns of disease and possibly the cause of death. Postmortem CT images bring to light processes of decomposition most radiologists are unfamiliar with. These postmortem changes, such as the formation of gas and edema, should not be mistaken for pathological processes that occur in living persons. In this review we discuss the normal postmortem thoraco-abdominal changes and how these appear on CT images, as well as how to differentiate these findings from those of pathological processes

    The accuracy and safety aspects of a novel robotic needle guide manipulator to perform transrectal prostate biopsies.

    No full text
    Contains fulltext : 88990.pdf (publisher's version ) (Closed access)PURPOSE: To introduce a new in-house developed pneumatically controlled magnetic field compatible manipulator as an aid to perform magnetic resonance (MR)-guided biopsies of the prostate. METHODS: A pneumatic controlled manipulator with five degrees of freedom constructed of plastic to achieve magnetic field compatibility was developed to guide biopsies. A risk analysis, mechanical tests, and RF safety tests with respect to needle tip heating were performed to assure future patient safety and to meet standard safety requirements for the use in a medical environment. The accuracy of needle positioning with the needle guide manipulator to sample a predefined target was measured in agar phantoms on a 3 T whole body MR system. The in-plane error was used to evaluate the accuracy, which is defined as the orthogonal distance between target and biopsy needle. The time for each step in the biopsy procedure was recorded to evaluate the procedure time. The influence of the insertion angle with respect to the static field of the MR scanner on the needle artifact was investigated. RESULTS: The risk analyses met patient safety requirements. No RF induced local heating around the needle tip was observed. The average in-plane error in 19 measurements was 3.0 mm (range 0-5.6 mm). The average time needed for manipulation to place the needle guide in the desired position was 5 min (range 3-8 min). Total procedure time was 30 min. The needle artifact size increases with the insertion angle with respect to the static field of the MR scanner. CONCLUSIONS: The new MR compatible manipulator can be used safely for patient care. It showed a high accuracy and short total procedure time, demonstrating great potential to improve the transrectal prostate biopsy procedure.01 september 201
    corecore