1,128 research outputs found

    Nonlinearities in Fringe-Counting Compact Michelson Interferometers

    Get PDF
    Compact Michelson interferometers are well positioned to replace existing displacement sensors in the readout of seismometers and suspension systems, such as those used in contemporary gravitational-wave detectors. Here, we continue our previous investigation of a customised compact displacement sensor built by SmarAct that operates on the principle of deep frequency modulation. The focus of this paper is the linearity of this device and its subsequent impact on sensitivity. We show the three primary sources of nonlinearity that arise in the sensor: residual ellipticity, intrinsic distortion of the Lissajous figure, and distortion caused by exceeding the velocity limit imposed by the demodulation algorithm. We verify the theoretical models through an experimental demonstration, where we show the detrimental impact that these nonlinear effects have on device sensitivity. Finally, we simulate the effect that these nonlinearities are likely to have if implemented in the readout of the Advanced LIGO suspensions and show that the noise from nonlinearities should not dominate across the key sub-10 Hz frequency band

    Misaligned spin and orbital axes cause the anomalous precession of DI Herculis

    Full text link
    The orbits of binary stars precess as a result of general relativistic effects, forces arising from the asphericity of the stars, and forces from additional stars or planets in the system. For most binaries, the theoretical and observed precession rates are in agreement. One system, however -- DI Herculis -- has resisted explanation for 30 years. The observed precession rate is a factor of four slower than the theoretical rate, a disagreement that once was interpreted as evidence for a failure of general relativity. Among the contemporary explanations are the existence of a circumbinary planet and a large tilt of the stellar spin axes with respect to the orbit. Here we report that both stars of DI Herculis rotate with their spin axes nearly perpendicular to the orbital axis (contrary to the usual assumption for close binary stars). The rotationally induced stellar oblateness causes precession in the direction opposite to that of relativistic precession, thereby reconciling the theoretical and observed rates.Comment: Nature, in press [11 pg

    Design and sensitivity of a 6-axis seismometer for gravitational wave observatories

    Get PDF
    We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fiber. We utilize custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localization of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force

    Design and sensitivity of a 6-axis seismometer for gravitational wave observatories

    Full text link
    We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fibre. We utilise custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localisation of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force

    Nonperturbative and perturbative aspects of photo- and electroproduction of vector mesons

    Get PDF
    We discuss various aspects of vector meson production, first analysing the interplay between perturbative and nonperturbative aspects of the QCD calculation. Using a general method adapted to incorporate both perturbative and nonpertubative aspects, we show that nonperturbative effects are important for all experimentally available values of the photon virtuality Q2. We compare the huge amount of experimental information now available with our theoretical results obtained using a specific nonperturbative model without free parameters, showing that quite simple features are able to explain the data.Comment: 19 page

    Active platform stabilization with a 6D seismometer

    Get PDF
    We demonstrate the control scheme of an active platform with a six degree of freedom (6D) seismometer. The inertial sensor simultaneously measures translational and tilt degrees of freedom of the platform and does not require any additional sensors for the stabilization. We show that a feedforward cancelation scheme can efficiently decouple tilt-to-horizontal coupling of the seismometer in the digital control scheme. We stabilize the platform in the frequency band from 250 mHz up to 10 Hz in the translational (X, Y) degrees of freedom and achieve a suppression factor of 100 around 1 Hz. Further suppression of ground vibrations was limited by the non-linear response of the piezo actuators of the platform and by its limited range (5 lm). In this paper, we discuss the 6D seismometer, its control scheme, and the limitations of the test bed

    Gravitational Waves From Known Pulsars: Results From The Initial Detector Era

    Get PDF
    We present the results of searches for gravitational waves from a large selection of pulsars using data from the most recent science runs (S6, VSR2 and VSR4) of the initial generation of interferometric gravitational wave detectors LIGO (Laser Interferometric Gravitational-wave Observatory) and Virgo. We do not see evidence for gravitational wave emission from any of the targeted sources but produce upper limits on the emission amplitude. We highlight the results from seven young pulsars with large spin-down luminosities. We reach within a factor of five of the canonical spin-down limit for all seven of these, whilst for the Crab and Vela pulsars we further surpass their spin-down limits. We present new or updated limits for 172 other pulsars (including both young and millisecond pulsars). Now that the detectors are undergoing major upgrades, and, for completeness, we bring together all of the most up-to-date results from all pulsars searched for during the operations of the first-generation LIGO, Virgo and GEO600 detectors. This gives a total of 195 pulsars including the most recent results described in this paper.United States National Science FoundationScience and Technology Facilities Council of the United KingdomMax-Planck-SocietyState of Niedersachsen/GermanyAustralian Research CouncilInternational Science Linkages program of the Commonwealth of AustraliaCouncil of Scientific and Industrial Research of IndiaIstituto Nazionale di Fisica Nucleare of ItalySpanish Ministerio de Economia y CompetitividadConselleria d'Economia Hisenda i Innovacio of the Govern de les Illes BalearsNetherlands Organisation for Scientific ResearchPolish Ministry of Science and Higher EducationFOCUS Programme of Foundation for Polish ScienceRoyal SocietyScottish Funding CouncilScottish Universities Physics AllianceNational Aeronautics and Space AdministrationOTKA of HungaryLyon Institute of Origins (LIO)National Research Foundation of KoreaIndustry CanadaProvince of Ontario through the Ministry of Economic Development and InnovationNational Science and Engineering Research Council CanadaCarnegie TrustLeverhulme TrustDavid and Lucile Packard FoundationResearch CorporationAlfred P. Sloan FoundationAstronom

    Anisotropic flow of charged hadrons, pions and (anti-)protons measured at high transverse momentum in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}}=2.76 TeV

    Get PDF
    The elliptic, v2v_2, triangular, v3v_3, and quadrangular, v4v_4, azimuthal anisotropic flow coefficients are measured for unidentified charged particles, pions and (anti-)protons in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm NN}} = 2.76 TeV with the ALICE detector at the Large Hadron Collider. Results obtained with the event plane and four-particle cumulant methods are reported for the pseudo-rapidity range η<0.8|\eta|<0.8 at different collision centralities and as a function of transverse momentum, pTp_{\rm T}, out to pT=20p_{\rm T}=20 GeV/cc. The observed non-zero elliptic and triangular flow depends only weakly on transverse momentum for pT>8p_{\rm T}>8 GeV/cc. The small pTp_{\rm T} dependence of the difference between elliptic flow results obtained from the event plane and four-particle cumulant methods suggests a common origin of flow fluctuations up to pT=8p_{\rm T}=8 GeV/cc. The magnitude of the (anti-)proton elliptic and triangular flow is larger than that of pions out to at least pT=8p_{\rm T}=8 GeV/cc indicating that the particle type dependence persists out to high pTp_{\rm T}.Comment: 16 pages, 5 captioned figures, authors from page 11, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/186

    Centrality dependence of charged particle production at large transverse momentum in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm{NN}}} = 2.76 TeV

    Get PDF
    The inclusive transverse momentum (pTp_{\rm T}) distributions of primary charged particles are measured in the pseudo-rapidity range η<0.8|\eta|<0.8 as a function of event centrality in Pb-Pb collisions at sNN=2.76\sqrt{s_{\rm{NN}}}=2.76 TeV with ALICE at the LHC. The data are presented in the pTp_{\rm T} range 0.15<pT<500.15<p_{\rm T}<50 GeV/cc for nine centrality intervals from 70-80% to 0-5%. The Pb-Pb spectra are presented in terms of the nuclear modification factor RAAR_{\rm{AA}} using a pp reference spectrum measured at the same collision energy. We observe that the suppression of high-pTp_{\rm T} particles strongly depends on event centrality. In central collisions (0-5%) the yield is most suppressed with RAA0.13R_{\rm{AA}}\approx0.13 at pT=6p_{\rm T}=6-7 GeV/cc. Above pT=7p_{\rm T}=7 GeV/cc, there is a significant rise in the nuclear modification factor, which reaches RAA0.4R_{\rm{AA}} \approx0.4 for pT>30p_{\rm T}>30 GeV/cc. In peripheral collisions (70-80%), the suppression is weaker with RAA0.7R_{\rm{AA}} \approx 0.7 almost independently of pTp_{\rm T}. The measured nuclear modification factors are compared to other measurements and model calculations.Comment: 17 pages, 4 captioned figures, 2 tables, authors from page 12, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/284
    corecore