29 research outputs found
Endothelial function, regulation of angiogenesis and embryonic central hemodynamics in ART-conceived pregnancies
This study was undertaken to compare the concentrations of pro- and anti-angiogenic growth factors, nitric oxide (NO) stable metabolites in maternal serum and embryonic left ventricular (LV) isovolumic relaxation time (IRT, ms) during the first trimester in two groups of women: with pregnancy conceived by assisted reproductive technologies (ART, nј39) and normally conceived (control group, nј68) pregnancy. The concentration of vasoconstrictor endothelin 1 was 45.5 times more in ART than in control group. On the contrary, the concentrations of NO stable metabolites in ART were 1.9 times less than in control women. The assessment of angiogenic suppressors in ART women demonstrates the decrease in s-endoglin concentration was 1.6 times and in soluble receptor to vascular endothelial growth factor concentration was 2.0 times in comparison with control group. There was a significant increase in LV IRT in ART embryos in comparison to control ones. These data suggest significant changes in pro-antiangiogenic factors balance and increase in vascular impedance in ART-conceived embryos
Nonspecific synaptic plasticity improves the recognition of sparse patterns degraded by local noise
Safaryan, K. et al. Nonspecific synaptic plasticity improves the recognition of sparse patterns degraded by local noise. Sci. Rep. 7, 46550; doi: 10.1038/srep46550 (2017). This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ © The Author(s) 2017.Many forms of synaptic plasticity require the local production of volatile or rapidly diffusing substances such as nitric oxide. The nonspecific plasticity these neuromodulators may induce at neighboring non-active synapses is thought to be detrimental for the specificity of memory storage. We show here that memory retrieval may benefit from this non-specific plasticity when the applied sparse binary input patterns are degraded by local noise. Simulations of a biophysically realistic model of a cerebellar Purkinje cell in a pattern recognition task show that, in the absence of noise, leakage of plasticity to adjacent synapses degrades the recognition of sparse static patterns. However, above a local noise level of 20 %, the model with nonspecific plasticity outperforms the standard, specific model. The gain in performance is greatest when the spatial distribution of noise in the input matches the range of diffusion-induced plasticity. Hence non-specific plasticity may offer a benefit in noisy environments or when the pressure to generalize is strong.Peer reviewe
Recommended from our members
Search for Production of Invisible Final States in Single-Photon Decays of
We search for single-photon decays of the resonance, invisible, where the invisible state is either a particle of definite mass, such as a light Higgs boson , or a pair of dark matter particles, . Both and χ are assumed to have zero spin. We tag decays with a dipion transition and look for events with a single energetic photon and significant missing energy. We find no evidence for such processes in the mass range and in the sample of decays collected with the BABAR detector and set stringent limits on new physics models that contain light dark matter states.Physic
The Physics of the B Factories
This work is on the Physics of the B Factories. Part A of this book contains a brief description of the SLAC and KEK B Factories as well as their detectors, BaBar and Belle, and data taking related issues. Part B discusses tools and methods used by the experiments in order to obtain results. The results themselves can be found in Part C
Label-Free, Single Molecule Resonant Cavity Detection: A Double-Blind Experimental Study
Optical resonant cavity sensors are gaining increasing interest as a potential diagnostic method for a range of applications, including medical prognostics and environmental monitoring. However, the majority of detection demonstrations to date have involved identifying a “known” analyte, and the more rigorous double-blind experiment, in which the experimenter must identify unknown solutions, has yet to be performed. This scenario is more representative of a real-world situation. Therefore, before these devices can truly transition, it is necessary to demonstrate this level of robustness. By combining a recently developed surface chemistry with integrated silica optical sensors, we have performed a double-blind experiment to identify four unknown solutions. The four unknown solutions represented a subset or complete set of four known solutions; as such, there were 256 possible combinations. Based on the single molecule detection signal, we correctly identified all solutions. In addition, as part of this work, we developed noise reduction algorithms
Media 1: Photoelastic ultrasound detection using ultra-high-Q silica optical resonators
Originally published in Optics Express on 17 November 2014 (oe-22-23-28169
Synaptic Transmission in the Neocortex during Reversible Cooling
We studied the effects of reversible cooling on synaptic transmission in slices of rat visual cortex. Cooling had marked monotonic effects on the temporal properties of synaptic transmission. It increased the latency of excitatory postsynaptic potential
Recommended from our members
Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider
The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance